Module Spare Parts 9907-1200

Module Spare Parts 9907-1200 photo-1
US$ 1 - 100000 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
GE
Model Number:
9907-1200
Payment & Shipping
Payment Methods:
Port of Shipment:
xiamen
Delivery Detail:
1 days
Brand Name GE
Model Number 9907-1200


Focus on DCS, PLC, robot control system and large servo system.

Main products: various modules / cards, controllers, touch screens, servo drivers.

Advantages: supply of imported original products, professional production parts,

Fast delivery, accurate delivery time,

The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands

 

9907-018
9907-1200

IEC 61850 Connect For order of IEC 61850 related products, local organizations must comply with the Demands on the Purchaser to secure successful sales of IEC 61850 with System 800xA. Ref doc, 3BSE058798. Article no. IEC 61850-Ed1 Connect, 800xA 5.1 Allows clients to access data directly from electrical devices (IEDs). Handles alarms from IEDs. Each item includes one IEC61850 OPC server instance and IEC 61850 Substation Operation Library with Faceplates to control substation equipment (Bay, Breaker, Switch,...) is included. 3BSE061369R1 Redundant IEC 61850-Ed1 Connect Option, 800xA 5.1 Allows operation clients to access data and alarm and event values from Intelligent Electronic Devices (IEDs) through redundant Connectivity Servers. Requires IEC 61850-Ed1 Connect. The number of Redundant IEC 61850 OPC server instance licenses shall be less then or equal to the number of IEC 61850 OPC server instances, when redundancy is chosen.(max. 16 per System). 3BSE061370R1 Libraries Article no. INFI90 Function Code Library for AC 800M, 800xA 5.1 Requires separate media. 3BSE061211R1 MOD 300 CCF Library for AC 800M, 800xA 5.1 Requires separate media. 3BSE061210R1 TCP Communication Library License Control functions to create TCP based communication protocols in the AC800M controller. Once licence is needed for each controller using the library. Note: At pricebook release this item required a TSA to be ordered. Please, check current need of a TSA in the TSA Database before ordering. 3BSE070889R1 UDP Communication Library License Control functions to create UDP based communication protocols in the AC800M controller. Once licence is needed for each controller using the library. Note: At pricebook release this item required a TSA to be ordered. Please, check current need of a TSA in the TSA Database before ordering. 3BSE070891R1 Machine Safety Library License Points Control functions for machine safety applications. Same amount of library points is needed as the summed up controller capacity points using the library. Note: At pricebook release this item required a TSA to be ordered. Please, check current need of a TSA in the TSA Database befo(Max 2500 per Connectivity Server if OPC Communication is used. For details refer to System Guide) Article no. 100 HART Device Aspect Objects, 800xA 5.1 3BSE061359R1 1,000 HART Device Aspect Objects, 800xA 5.1 3BSE061360R1 10,000 HART Device Aspect Objects, 800xA 5.1 3BSE061361R1 HART Multiplexer Connect, 800xA 5.1 Enables HART Device Integration to connect to HART devices using HART Multiplexers. 3BSE061362R1 Device Management FOUNDATION Fieldbus For FOUNDATION Fieldbus (FF) devices to be accessed using Fieldbus Builder FF within System 800xA. Includes FF Device Library with FF Device Aspect Objects, FF Instruments Asset Monitor L ibrary and OPC Server. Each FF device aspect object counts as one. (Max 1000 per Connectivity Server. For details refer to System Guide.) Article no. 100 FF Device Aspect Objects, 800xA 5.1 3BSE061363R1 1,000 FF Device Aspect Objects, 800xA 5.1 3BSE061364R1 10,000 FF Device Aspect Objects, 800xA 5.1 3BSE061365R1 Device Management PROFIBUS For PROFIBUS DP/PA devices to be accessed using Device Type Manager (DTM‘s) within System 800xA. Includes PROFIBUS Device Library with specific PROFIBUS Device Aspect Objects incl. DTM‘s, I/O DTM for S800 and S900, and PROFIBUS Instruments Asset Monitor Library. Each PROFIBUS device aspect object accessed with DTM counts as one. (Max 2500 per Connectivity Server if OPC communication is used. For details refer to System Guide.) Dual History Signals - 1000 signals Note: At pricebook release a TSA was NEEDED for this item. Please, check current need of a TSA in the TSA Database before ordering. 3BSE073477R10only Hierarchical Logs. (Total max 300,000 and max 50,000/Server.) Article no. 100 History Logs, 800xA 5.1 3BSE061266R1 1,000 History Logs, 800xA 5.1 3BSE061267R1 15,000 History Logs, 800xA 5.1 3BSE061268R1 Dual History Logs For parallel logging in two history servers. (Two Basic Historian Servers are required). Number of initial Information Management Hierarchical Logs in the system. Each signal to be logged counts as one log. Note: Information Management provides only Hierarchical Logs. (Total max 150,000 and max 50,000/Server.) Article no. 100 Dual History Logs, 800xA 5.1 3BSE061269R1 1,000 Dual History Logs, 800xA 5.1 3BSE061270R1 15,000 Dual History Logs, 800xA 5.1 3BSE061271R1

Product Tags: spot goods , Large warehouse management

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market

Recommended Categories

Explore top categories and find suppliers for your specific needs