Module Spare Parts 7DO135.70
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
| 7DO135.70 |
Parameters Range of values Default Parameter reassignment in RUN Scope with configuration software, e.g. STEP 7 (TIA Portal) GSD file PROFINET IO GSD file PROFIBUS DP 1 Reaction to CPU STOP • Turn off • Keep last value • Output substitute value 1 Turn off Yes Channel Module Potential group • Use potential group of the left module (module plugged into a dark-colored BaseUnit) • Enable new potential group (module plugged into lightcolored BaseUnit) Use potential group of the left module No Module Module 1 Due to the limited number of parameters of a maximum of 244 bytes per ET 200SP station with a PROFIBUS GSD configuration, the parameter assignment options are restricted. The parameter length of the I/O module is 6 bytes with PROFIBUS GSD configuration. If necessary, you can set this parameter by using the data record 128, see the appendix "Parameter data record". Note • If both parameters "Diagnostics: short-circuit to L+" and "Diagnostics: wire break" are enabled and one of these diagnostic events occurs, the affected channel is switched off. This prevents undefined load switching and the corresponding diagnostic alarm is triggered. • If both parameters "Diagnostics: short-circuit to L+" and "Diagnostics: wire break" are enabled and one of these diagnostic events occurs, the affected channel is switched off. This prevents undefined load switching and the corresponding diagnostic alarm is triggered. • If the parameter "Diagnostics: short-circuit to L+" is enabled and "Diagnostics: wire break" is disabled, the signal status is retained at the affected channel when "Diagnostics: shortcircuit to L+" occurs. A diagnostic alarm is triggered only for 0 signal. Parameters/address space 4.2 Declaration of parameters Digital output module DQ 16x24VDC/0.5A ST (6ES7132-6BH01-0BA0) 16 Manual, 02/2019, A5E03574420-AF 4.2 Declaration of parameters Diagnostics: No supply voltage L+ Enabling of the diagnostics for no or insufficient supply voltage L+. Diagnostics: Short-circuit to ground Enabling of the diagnostics if a short-circuit of the actuator supply to ground occurs. Diagnostics: Short-circuit to L+ Enabling of the diagnostics if a short-circuit of the actuator supply to L+ occurs. Diagnostics: Wire break Enabling of the diagnostics if the line to the actuator is broken. Channel activated Determines whether a channel is activated or deactivated
Send Inquiry to This Supplier
You May Also Like
-
Module Spare Parts CS-1000 UTX1700PTFEUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts E33NRHA-LNN-NS-00US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts ECPSR086370-001US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts EI813F 3BDH000022R1US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts EL3040 02402893521100US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts SCM-1US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts SUITE T940X,XAPMM,BATT,ENGUS$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts N.104-19N.143-18 IB3110050US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts N.132-18N.143-18 IB3110050US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts N.145-18N.105-19 IB3110050US$ 1 - 100000MOQ: 1 Piece