US$ 1067 - 2058 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
ABB
Place of Origin:
China
Model Number:
TK803V018
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
1 days
Brand Name ABB
Place of Origin China
Model Number TK803V018

Brand: ABB

Type:TK803V018

Origin: the Swiss

Warranty: 365 days

Colour: new/used

Shipping method: Courier delivery

Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts of our products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.

MESSAGE 8 MEANING External Trip Input External Trip contact input was opened External Trip 2 External Trip #2 contact input was opened External Trip 3 External Trip #3 contact input was opened External Trip 4 External Trip #4 contact input was opened External Trip 5 External Trip #5 contact input was opened Emer Shutdown Button Emergency Shutdown on the 505E front panel was pressed Overspeed Turbine overspeed was sensed All Speed Probes Failed Loss of all speed probes was sensed Act #1 (HP) Fault Actuator #1 fault detected (an open or short circuit was sensed) Act #2 (LP) Fault Actuator #2 fault detected (an open or short circuit was sensed) Aux Input Failed Aux analog input failure detected ( > 22 mA or

gital Governor Manual 85018V1 178 Woodward Speed, Casc, Aux, and Ext/Adm Dynamics Adjustments Dynamic control values are programmed in the program mode and adjusted in the RUN mode. While in the run mode, pressing the DYN key calls up the dynamic adjustments of the parameter in control. The Proportional and Integral Gain dynamic adjustments are available under their respective keys (i.e. SPEED, CAS, AUX, & EXT/ADM).

 The Derivative term adjustments are made in the Service Mode—(7-4 see volume 2). To adjust the gain settings, the @ symbol must be on the display line containing the asterisk/gain value to tune. The @ symbol is moved using the SELECT key. The ADJUST UP and DOWN keys can then be used to adjust the function on the line with the @ symbol. The Speed, Cascade, Auxiliary, and Extr/Adm controls are PID controllers. The response of each control loop can be adjusted by selecting the dynamics mode as described above. Proportional gain, integral gain (stability), and SDR (speed derivative ratio) are the adjustable and interacting parameters used to match the response of the control loop with the response of the system. They correspond to the P (proportional), I (integral), and D (derivative) terms, and are displayed by the 505E as follows: P = Proportional gain (%) I = Integral gain (%) D = Derivative (determined by SDR and I) NOTE If an older type 505E is being replaced by a new 505E, the “ P & D ” terms may be the same, however, the “ I ” term should be reduced by a factor of 10 from the old 505E’s reset value to achieve the same control response.

Product Tags: DCS control module , Industrial control equipment , PLC redundant module