Module Spare Parts WES5302 WES5302-111
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
| WES5302 WES5302-111 |
Do not use antistatic or electrically conductive breathing tubes or masks. Check all connections to the breathing circuit to make sure that there are no unintended connections made to other equipment, especially equipment that delivers fluids, as the patient could be harmed. The inspiratory safety guard is required to connect the breathing circuits to the ventilator. The inspiratory safety guard must be used at all times during ventilation. See "Cleaning and maintenance" for information on the replacement of the inspiratory safety guard. See "Parts and accessories" for ordering information. The exhalation valve heater should be used when an active humidifier with a heated expiratory limb is used. Consult your hospital guidelines for proper use of expiratory filters in conjunction with heated humidifiers. WARNING • • Note Important CARESCAPE™ R860 4-14 2065490-001 Connecting the water trap to the breathing circuit 1. Connect the patient circuit to the front port of the water trap housing. 2. Connect the water trap connector tubing to the top port of the water trap housing. 3. Connect the water trap connector tubing to the expiratory filter (if used) or expiratory port. AB.100.166 2 3 1 Figure 4-5 • Cart-mounted water trap 1. Water trap connector tubing 2. Water trap housing 3. Water trap 4 Setup and connections 2065490-001 4-15 Connecting a HME (heat and moisture exchanger) To prevent excessive resistance in the breathing circuit, the HMEF500 should not be used for Adult patients. If using optional accessories see Figure in "Connecting the Pedilite(+) and D-lite(+) sensors". 1. Connect the inspiratory safety guard to the inspiratory port. 2. Attach the inspiratory limb of the patient circuit to the inspiratory safety guard. 3. Attach the expiratory limb of the patient circuit to the expiratory port or expiratory filter (if used). 4. Connect the Pedi-lite(+) or D-lite(+) sensor to the patient wye (if used). Use a 5 ml (minimum) spacer and elbow when using the Pedi-lite(+) or D-lite(+) sensor. 5. Connect the HME. • Place the HME between the SpiroDynamics catheter (if used), but after the Pedi-lite(+) and D-lite(+) sensor (if used). • The HME should be removed when a nebulizer is active. Replace the HME when the nebulizer is not in use. 6. Connect the circuit elbow to the HME (if used). To disconnect, follow instructions in reverse order. INSP EXP AB.100.188 Total Spont Menu Adult Current Mode FiO2 30 % Pinsp 33 cmH2O Rate 10 /min Tinsp 1.7s PEEP 5 cmH2O PS 5 cmH2O Standby Insp Hold Exp Hold Manual Breath 14:38 FiO2 No Alarms Airway Pressure cmH2O 60 40 20 0 -5 Pmax Ppeak PEEP VTexp 508 30 % 40 22 PEEPe 5 cmH2O 10 3 Peak Pressure 40 cmH2O 50 10 Minute Volume 6.2 l/min 12 4 Tidal Volume 508 ml 600 400 Respiratory Rate 14 /min 20 5 Total Spont 1 2 5 6
Send Inquiry to This Supplier
You May Also Like
-
Module Spare Parts 1C31129G03US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 1C31166G01US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 1C31166G02US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 1C31179G02US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 1C31203G01US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 1C31205G01US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 1C31206G01US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 1C31219G01US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 1C31222G01US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 1TGE120021R0010US$ 1 - 100000MOQ: 1 Piece