TRICONEX 3201

TRICONEX 3201 photo-1
US$ 1051 - 2270 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
TRICONEX
Place of Origin:
China
Model Number:
TRICONEX 3201
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
1 days
Brand Name TRICONEX
Place of Origin China
Model Number TRICONEX 3201

Brand:TRICONEX

Type:3201

Origin: the United States

Warranty: 365 days

Colour: new/used

Shipping method: Courier delivery

Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.

USE AUTO START SEQUENCE ? dflt= NO (Yes/No) Enter YES followed by ENTER if this function is desired. If NO is selected followed by ENTER, then the program will step to ‘Reset Clears Trip Output’ question. If this function is programmed and RUN is selected, the 505E automatically accelerates the speed setpoint to a programmable low idle speed and holds for a programmable time then ramps to a programmable high idle speed and holds for a programmable time then ramps to programmable rated speed setpoint. The start sequence can be actuated or halted through the keypad, Modbus or external switch. COLD START ( > xx HRS ) dflt= 10 (0.0, 200) Enter the time in hours allowed after a trip before the ‘cold start’ sequence curves are to be used followed by the ENTER key. If this much time has expired (or more) after a trip condition, then the control will use the cold start values. If less than this time has expired, the control will interpolate between the hot and cold start values to determine rates and hold times. HOT START (

Product Tags: Control processor , Robot module , DCS, PLC card

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market

Recommended Categories

Explore top categories and find suppliers for your specific needs