TRICONEX 8111
Brand: TRICONEX
Type:8111
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts of our products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
See AuxFBDivisor to complete the setup of the Aux Feedback interface. Note: Many EnDat 2.2 devices can be wired to the J14 AuxFB Connector as long as the 1 Vp-p Sin-Cos analog signals are also wired and the device will run in EnDat 2.1 compatibility mode. Power up initialization of absolute position will work. BatFDis Enable/Disable This parameter enables or disables the Battery Low fault. The Battery input on the command I/O connector is an optional feature and is not required for proper operation of the drive. It is only required if the battery backup of the multi-turn information is required from the SFD. If the feedback device is not an SFD, then the battery does nothing. 0 - Enable Battery Fault 1 - Disable Battery Fault CmdF0 1.518 – 93254 Hz CmdF0 sets the break frequency in Hz for two cascaded single pole low pass filters on the hardware command input. There are two ranges of values for CmdF0; from 2915 to 24873 Hz cannot be set. The lower range is the active range suggested for velocity control and the upper range is used to effectively turn the filter off for velocity control or for use with torque/current control. This parameter is particularly useful when CmdSrc selects the PWM input for the command source. CmdF0 should be less than the input PWM frequency divided by 10 and preferably divided by 50 or more. See the Base Drive Torque/Velocity Control Block Diagram for more information. CmdGain See Chart CmdGain sets the scale factor from the user input on the Command I/O connector (J4) to the internal servo loop command. CmdGain can be negative or positive, which allows the direction polarity to be changed. Because the input to the command processing block can be an analog voltage or a digital duty cycle and the servo loop could be Torque/Current or velocity there are four combinations of units listed below. See CmdSrc and OpMode for these settings. See CmdOffset for adding an offset to the command. Expressed as an equation: CmdIn = [(User Input) – CmdOffset] * CmdGain NOTE: The Range of CmdGain is clipped by the value of CmdOffset. The chart below gives CmdGain units and numerical range assuming that CmdOffset is 0 V/50%. CmdSrc OpMode CmdGain Units +/- CmdGain Range Analog Torque / Current ARMS / V ARMS / V Analog Velocity krpm / V krpm / V PWM Torque / Current ARMS / % ARMS / % PWM Velocity krpm / % krpm / % CmdInNullEnb Enable/Disable CmdInNullEnb enables or disables the Command In ADC Null function. CmdInNullEnb enabled allows the user to null the base drive CmdIn ADC by asserting DInp4 for a minimum of one second.

Send Inquiry to This Supplier
You May Also Like
-
TRICONEX EPI3382 7400221US$ 1121 - 2131MOQ: 1 Piece
-
TRICONEX 3721CUS$ 1153 - 2053MOQ: 1 Piece
-
TRICONEX 3481US$ 1167 - 2067MOQ: 1 Piece
-
TRICONEX 8312US$ 1203 - 2212MOQ: 1 Piece
-
TRICONEX AIH 3723XUS$ 1205 - 2214MOQ: 1 Piece
-
TRICONEX DO 3626XUS$ 1205 - 2214MOQ: 1 Piece
-
TRICONEX DI 3506XUS$ 1205 - 2214MOQ: 1 Piece
-
TRICONEX IMSS 4701XUS$ 1205 - 2214MOQ: 1 Piece
-
TRICONEX PLM 3900NUS$ 1207 - 2216MOQ: 1 Piece
-
TRICONEX 2101US$ 1050 - 2269MOQ: 1 Piece