HIMA F6217

HIMA F6217 photo-1
US$ 1150 - 2050 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
HIMA
Place of Origin:
China
Model Number:
F6217
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
1 days
Brand Name HIMA
Place of Origin China
Model Number F6217

Brand:HIMA

Type:F6217

Origin: the United States

Warranty: 365 days

Colour: new/used

Shipping method: Courier delivery

Spare parts spare parts, the main DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

Possible Cause 1: The CI869 module is in the process of upgrading the firmware (if the upgrade is in progress). Corrective Action 1: Wait for the firmware to be upgraded. Possible Cause 2: Fault in the CI869 module. Corrective Action 2: Hot remove and hot insert the CI869 module. Corrective Action 3: If the indication persists after performing the corrective actions 1 and 2, then replace the CI869 module. Rx LED is ON (without flashing) The CI869 module is operational, and it is receiving and transmitting data. Rx LED is flashing with less frequency Possible Cause 1: The twisted wire pair (TWP) is not connected or it is not connected properly to the 4-pin contact. Corrective action 1: Check the TWP connections. Rx LED is flashing with 50% more frequency than when the TWP is not connected Possible Cause 1: The configuration is not downloaded from the Hardware Tree (in the Control Builder) to the controller. Corrective Action 1: Ensure that the CI869 module is configured in the Hardware Tree for the correct position and the configuration is downloaded to controller. Rx LED is flashing with 75% more frequency than when the TWP is not connected Possible Cause: At least one of the configured DSPs does not respond when polled. Corrective Action: Configure the DSPs correctly.

The CI869 module is run in redundant configuration. Prim(ary) LED is ON The CI869 module is run in redundant configuration, and it functions as the primary module. Note: Even if the backup CI869 module runs with errors or fails in redundant configuration, the Prim LED is still ON in the primary CI869 module in redundant configuration. If the corrective action is to replace the faulty CI869 module, replace it with another CI869 module which has the same version of hardware and firmware. CI869 supports hot swap.

Product Tags: Warehouse stock , DCS control module , PLC automatic card