Xlpe Abc Cable
xlpe abc cable
Standards: B-230 Aluminum Wire, 1350-H19 for Electrical Purposes. B-231 Aluminum conductors, Concentric-Lay-Stranded. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR). B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors. B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR). Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
Note: Designated sizes are : ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTMB-399 for 6201.Conductor temperature of 90 for XLR 75 for Poly; ambient temperatures of 40 ; emissivity 0.9; 2ft./sec/wind in sun. To determine current ampacity by conductor size, please consult The National Electric Code, latest edition
Quadruplex Service Drop Aluminum Conductors ACSR Neutral-Messenger:
| Code Name | Phase conductor | Bare Neutral Messenger | Weight per 1000ft | Rating | ||||||
| Size | Stranding | Insulation thickness | Size | Stranding | Breaking strength | XLP | Poly | XLP | Poly | |
| AWG | mls | AWG | Lbs | Lbs | Lbs | Amps | Amps | |||
| Morochuca | 6 | 7/w | 45 | 6 | 6/1 | 1190 | 152 | 147.4 | 75 | 60 |
| Chola | 6 | Solid | 45 | 6 | 6/1 | 1190 | 162 | 151.7 | 75 | 60 |
| Morgan | 4 | 7/w | 45 | 4 | 6/1 | 1860 | 226 | 220 | 100 | 80 |
| Hackney | 4 | 7/w | 45 | 4 | 6/1 | 1860 | 241 | 226.1 | 100 | 80 |
| Palomino | 2 | 19/w | 45 | 2 | 6/1 | 2850 | 362 | 342.6 | 135 | 105 |
| Costena | 1/0 | 19/w | 60 | 1/0 | 6/1 | 4380 | 575 | 550.6 | 180 | 140 |
| Grullo | 2/0 | 19/w | 60 | 2/0 | 6/1 | 5310 | 707 | 678.7 | 205 | 160 |
| Suffolk | 3/0 | 19/w | 60 | 3/0 | 6/1 | 6620 | 872 | 838.9 | 235 | 185 |
| Appaloosa | 4/0 | 19/w | 60 | 4/0 | 6/1 | 8350 | 1079 | 1039.2 | 275 | 210 |
| Bronco | 336.4 | 19/w | 80 | 336.4 | 18/1 | 8580 | 1613 | 1568.2 | 370 | 280 |
| Gelding | 336.4 | 19/w | 80 | 4/0 | 6/1 | 8350 | 1548 | 1494.3 | 370 |
280 |
Quadruplex Service Drop Aluminum Conductors AAC Neutral-Messenger:
| Code Name | Phase conductor | Bare Neutral Messenger | Weight per 1000ft | Rating | ||||||
| Size | Stranding | Insulation thickness | Size | Stranding | Breaking strength | XLP | Poly | XLP | Poly | |
| AWG | mls | AWG | Lbs | Lbs | Lbs | Amps | Amps | |||
| Clydesdale | 4 | 7/w | 45 | 4 | 7 | 881 | 208 | 201.8 | 100 | 80 |
| Pinto | 4 | 7/w | 45 | 4 | 7 | 881 | 223 | 207.9 | 100 | 80 |
| Mustang | 2 | 19/w | 45 | 2 | 7 | 1350 | 333 | 312.6 | 135 | 105 |
| Criollo | 1/0 | 19/w | 60 | 1/0 | 7 | 1990 | 529 | 504.5 | 180 | 140 |
| Percheron | 2/0 | 19/w | 60 | 2/0 | 7 | 2510 | 649 | 620.5 | 205 | 160 |
| Hanoverian | 3/0 | 19/w | 60 | 3/0 | 19 | 3310 | 799 | 765.6 | 235 | 185 |
| Oldenburg | 4/0 | 19/w | 60 | 4/0 | 19 | 4020 | 986 | 946.7 | 275 | 210 |
| Lippizaner | 336.4 | Solid | 80 | 336.4 | 19 | 6146 | 1546 | 1519.2 | 370 | 280 |
Send Inquiry to This Supplier
You May Also Like
-
Low Voltage Abc CableUS$ 0.1 - 2MOQ: 5 Meters
-
Abc Cable Overhead CableUS$ 0.1 - 5.8MOQ: 5 Meters
-
Abc Cable Aerial Bundle CableUS$ 0.1 - 5.8MOQ: 5 Kilometers
-
Abc CableUS$ 0.1 - 5.8MOQ: 5 Kilometers
-
ABC CableUS$ 0.1 - 5.8MOQ: 5 Kilometers
-
0.6/1kv Overhead Abc CableUS$ 0.1 - 5.8MOQ: 5 Kilometers
-
CAAI 2X16+25sqmm ABC Cable Service Drop Cable With Volt 1000VUS$ 0.2 - 2MOQ: 500 Meters
-
Aluminum Conductor XLPE/PE/PVC Insulation Service Drop Cable/ Aerial Bundle Cable for Overhead Power Service ApplicationsUS$ 0.2 - 1.5MOQ: 1 Meter
-
XLPE Insulation Service Drop Cable SIP 3 50mm2 10KVUS$ 0.2 - 2MOQ: 500 Meters
-
Secondary Distribution Service Drop 35mm2 URD CableUS$ 0.2 - 4MOQ: 1000 Meters