Home > Electrical & Electronics > Power Transmission & Transformer > Transformer > 3kv, 6kv, 10kv Jdzx9-3, 6, 10q (B, C, D, E) Fully Enclosed Indoor Epoxy Cast-Resin Casting Insulation Type Single-Phase Potential Voltage Transformer PT With Fuse Protection Residual Voltage Winding

3kv, 6kv, 10kv Jdzx9-3, 6, 10q (B, C, D, E) Fully Enclosed Indoor Epoxy Cast-Resin Casting Insulation Type Single-Phase Potential Voltage Transformer PT With Fuse Protection Residual Voltage Winding

3kv, 6kv, 10kv Jdzx9-3, 6, 10q (B, C, D, E) Fully Enclosed Indoor Epoxy Cast-Resin Casting Insulation Type Single-Phase Potential Voltage Transformer PT With Fuse Protection Residual Voltage Winding photo-1
3kv, 6kv, 10kv Jdzx9-3, 6, 10q (B, C, D, E) Fully Enclosed Indoor Epoxy Cast-Resin Casting Insulation Type Single-Phase Potential Voltage Transformer PT With Fuse Protection Residual Voltage Winding photo-2
3kv, 6kv, 10kv Jdzx9-3, 6, 10q (B, C, D, E) Fully Enclosed Indoor Epoxy Cast-Resin Casting Insulation Type Single-Phase Potential Voltage Transformer PT With Fuse Protection Residual Voltage Winding photo-3
3kv, 6kv, 10kv Jdzx9-3, 6, 10q (B, C, D, E) Fully Enclosed Indoor Epoxy Cast-Resin Casting Insulation Type Single-Phase Potential Voltage Transformer PT With Fuse Protection Residual Voltage Winding photo-4
3kv, 6kv, 10kv Jdzx9-3, 6, 10q (B, C, D, E) Fully Enclosed Indoor Epoxy Cast-Resin Casting Insulation Type Single-Phase Potential Voltage Transformer PT With Fuse Protection Residual Voltage Winding photo-5
US$ 80 - 360 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
Enrich
Place of Origin:
China
Model Number:
JDZX9-3,6,10Q(B,C,D,E) ...
Payment & Shipping
Payment Methods:
Port of Shipment:
Chongqing
Delivery Detail:
15 days
Brand Name Enrich
Place of Origin China
Model Number JDZX9-3,6,10Q(B,C,D,E) ...
Usage Potential
Phase Single
Coil Number Autotransformer
Coil Structure Other

0.5-35kV Epoxy-resin potential/voltage transformer

 

0.5-12kV Epoxy-resin potential/voltage transformer

 

JDZX9-3,6,10Q(B,C,D,E) Fully enclosed indoor single-phase voltage transformer

 

Model description

 

JDZX9-3,6,10Q(B,C,D,E)

J: Voltage transformer

D: Single phase

Z: Casting insulation

X: With residual voltage winding

9: Design no.

3,6,10: Rated voltage(kV)

Q(B,C,D,E): Full operational mode(Structure code)

 

JDZX9-3Q  JDZX9-6Q  JDZX9-10Q
JDZX9-3B  JDZX9-6B JDZX9-10B 

10000/√3/100/√3/100/√3   10000/√3/100/√3/100/√3100/√3  0.2/0.2/6P(3P)-20/20/100  0.2/0.5/6P(3P)-20/30/100   0.5/0.5/6P(3P)-50/50/100

JDZX9-3C  JDZX9-6C  JDZX9-10C

JDZX9-3D  JDZX9-6D  JDZX9-10D

JDZX9-3E  JDZX9-6E  JDZX9-10E 

10000/√3/100/√3/100/√3   10000/√3/100/√3/100/√3100/√3  0.2/0.2/6P(3P)-40/40/150  0.2/0.5/6P(3P)-40/60/150   0.5/0.5/6P(3P)-100/100/150

 

JDZ(X)9-3,6,10B(C,D,E,GJ)Q(G)Fully enclosed indoor single-phase voltage transformer

 

Model description

JDZ(X)9-3,6,10B(C,D,E,GJ)Q(G)

J: Voltage transformer

D: Single phase

Z: Casting insulation

X: With residual voltage winding

9: Design no.

3,6,10: Rated voltage(kV)

B(C,D,E,GJ): Structure code

Q(G): Full operational mode(Full insulation)

 

JDZ(X)9-3,6,10B(C,D,E,GJ)Q(G)

JDZ9-3Q  JDZ9-6Q  JDZ9-10Q

JDZX9-3G  JDZX9-6G  JDZX9-10G

JDZ9-3BQ  JDZ9-6BQ  JDZ9-10BQ

JDZX9-3BG  JDZX9-6BG  JDZX9-10BG

JDZ9-3CQ  JDZ9-6CQ  JDZ9-10CQ

JDZX9-3CG  JDZX9-6CG  JDZX9-10CG

JDZ9-3D  JDZ9-6D  JDZ9-10D

JDZX9-3DG  JDZX9-6DG  JDZX9-10DG

JDZ9-3E  JDZ9-6E  JDZ9-10E

JDZX9-3EG  JDZX9-6EG  JDZX9-10EG

JDZX9-3GJ  JDZX9-6GJ  JDZX9-10GJ

 

JDZ9-3,6,10R1(2,3)Fully enclosed with fuse indoor single-phase voltage transformer

 

Model description

JDZ9-3,6,10R1(2,3)

J: Voltage transformer

D: Single phase

Z: Casting insulation

9: Design no.

3,6,10: Rated voltage(kV)

R: With fuse protection

1(2,3): Structure code

 

JDZ9-3R1  JDZ9-3R2

JDZ9-6R1  JDZ9-6R2

JDZ9-10R1  JDZ9-10R2

JDZ9-3R3  JDZ9-6R3  JDZ9-10R3

 

JDZ(X)9-3,6,10RJC voltage transformer& insulation parts for handcart

 

Model description

JDZ(X)9-3,6,10RJC

J: Voltage transformer

D: Single phase

Z: Casting insulation

X: Residual voltage winding

9: Design no.

3,6,10: Rated voltage(kV)

R: With fuse protection

JC: For handcart

 

JDZ9-3RJC  JDZ9-6RJC  JDZ9-10RJC

JDZX9-3RJC  JDZX9-6RJC  JDZX9-10RJC

ZJ9-10 RJC insulation part

 

JDZ(X)12(A)-3,6,10R(G)(2) Fully enclosed elbow seat type (with fuse) indoor single-phase voltage transformer

 

JDZ12-3  JDZ12-6  JDZ12-10

JDZX12-3G  JDZX12-6G  JDZX12-10G

JDZ12A-3  JDZ12A-6  JDZ12A -10

JDZ12A-3R  JDZ12A-6R  JDZ12A -10R

JDZ12A-3R2  JDZ12A-6R2  JDZ12A-10R2

 

JDZ(X)16-3,6,10A,B(G)Fully enclosed indoor single-phase voltage transformer

 

JDZ16-3A  JDZ16-6A  JDZ16-10A

JDZX16-3AG  JDZX16-6AG  JDZX16-10AG

JDZ16-3B  JDZ16-6B  JDZ16-10B

JDZX16-3BG  JDZX16-6BG  JDZX16-10BG

 

JDZ(X)16-3,6,10R(G) Fully enclosed with fuse indoor single-phase voltage transformer& backbone

 

JDZ16-3R  JDZ16-6R  JDZ16-10R

JDZX16-3RG  JDZX16-6RG  JDZX16-10RG(each 3pcs can be grouped)

ZJ16-10R insulation backbone

 

JDZX16-3,6,10Q(D)(G)(C,S)Fully enclosed indoor single-phase voltage transformer

 

JDZX16-3Q  JDZX16-6Q  JDZX16-10Q

JDZX16-3C  JDZX16-6C  JDZX16-10C

JDZX16-3D  JDZX16-6D  JDZX16-10D

JDZX16-3DG  JDZX16-6DG  JDZX16-10DG

JDZX16-3S  JDZX16-6S   JDZX16-10S

 

JDZ(X)18-3,6,10 1(2)(Q)(G)Fully enclosed indoor single-phase voltage transformer

 

JDZ18-3A  JDZ18-3AQ

JDZ18-6A  JDZ18-6AQ

JDZ18-10A  JDZ18-10AQ

JDZX18-3AG  JDZX18-6AG  JDZX18-10AG

JDZ18-3B1  JDZ18-3B2

JDZ18-6B1  JDZ18-6B2

JDZ18-10B1  JDZ18-10B2

JDZX18-3B1G  JDZX18-3B2G

JDZX18-6B1G  JDZX18-6B2G

JDZX18-10B1G  JDZX18-10B2G

JDZ18-3C1  JDZ18-3D

JDZ18-6C1  JDZ18-6D

JDZ18-10C1  JDZ18-10D

JDZX18-3C1G  JDZX18-3DG

JDZX18-6C1G  JDZX18-6DG

JDZX18-10C1G  JDZX18-10DG

 

JDZ(X)18-3,6,10( )R(V/G)Fully enclosed with fuse indoor single-phase voltage transformer

 

JDZ18-3R  JDZ18-6R  JDZ18-10R

JDZX18-3RG  JDZX18-6RG  JDZX18-10RG

JDZ18-3AR  JDZ18-6AR  JDZ18-10AR

JDZ18-3ARV  JDZ18-6ARV  JDZ18-10ARV

 

JDZX18-3,6,10A(B)Fully enclosed indoor single-phase voltage transformer

 

JDZX18-3A  JDZX18-6A  JDZX18-10A

JDZX18-3B  JDZX18-6B  JDZX18-10B

 

JDZX18-3,6,10R1(2,3,4)Fully enclosed with fuse indoor single-phase voltage transformer

 

JDZX18-3R1  JDZX18-3R3  JDZX18-3R4

JDZX18-6R1  JDZX18-6R3  JDZX18-6R4

JDZX18-10R1  JDZX18-10R3  JDZX18-10R4

JDZX18-3R2  JDZX18-6R2  JDZX18-10R2

 

JDZ(X)18-3,6,10R(V)JC voltage transformer& insulation backbone for handcart

 

JDZ18-3RJC  JDZ18-3RVJC

JDZ18-6RJC  JDZ18-6RVJC

JDZ18-10RJC  JDZ18-10RVJC

JDZX18-3RJC  JDZX18-6RJC  JDZX18-10RJC

ZJ18-10RJC  insulation backbone

Rated voltage ratio (A)

Accuracy class and accuracy class combination

Rated secondary output(VA)

Limited output(VA)

Rated insulation level(kV)

Rated secondary output(VA)

Surface creepage distance(mm)

Once fuse(A)






 

For the above mentioned parameters, other models/types, dimensions…, please kindly contact with us.


Product Tags: Fully Enclosed Indoor Single-Phase Voltage Transformer , Epoxy-Resin Potential/Voltage Transformer , Voltage Transformer with Casting Insulation , Residual Voltage Winding , Voltage Transformer with Fuse Protection , Potential Transformer for Handcart

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Trading Company
Overseas Office
Yes
Product Certifications
ISO9001, ISO9000, ISO14000
Port of Shipment
Chongqing

You May Also Like

Recommended Categories

Explore top categories and find suppliers for your specific needs