Low Voltage Cable 4x50mm Price Power Cable Xlpe Copper 3cx35sqmm Price
Application
The product is applicable for AC 50Hz transmission and distribution lines with rated voltage of 1.8/3KV or below.
The mechanical properties and electrical performance of cables meet the requirements of national standard GB/T12706- 2008 and international standards IEC60502-2005
Operating characteristics1. Cable laying temperature: ≥0°C
2. Cable conductor long-term allowable working temperature:≤90°C
3. Higest working temperature of cable in case of short circuit (the longest lasting time is not over 5s): 250°C
4. Minimum allowable bending radius: Single core cable: 20D mm; multi-core cable: 15D mm Note: D is actual outer diameter of the cable
Cable models, names, and laying occasionsModel |
Name |
Laying Occasion |
|
Copper core |
Aluminum core |
||
YJV |
YJLV |
XLPE insulated PVC sheathed power cable |
Laid indoors, and in tunnels and pipelines |
YJY |
YJLY |
XLPE insulated PE sheathed power cable |
|
YJV22 |
YJLV22 |
XLPE insulated steel tape armored PVC sheathed power cable |
Adapt for buried laying, not suitable for in-pipe laying |
YJV23 |
YJLV23 |
XLPE insulated steel tape armored PE sheathed power cable |
|
YJV32 |
YJLV32 |
XLPE insulated thin steel wire armored PVC sheathed power cable |
Laid on riverbeds of rivers or shallow water as connecting lines across rivers or petroleum/natural gas platforms, also used in land high drop areas. |
YJV33 |
YJLV33 |
XLPE insulated thin steel wire armored PVC sheathed power cable |
|
YJV42 |
YJLV42 |
XLPE insulated thick steel wire armored PVC sheathed power cable |
|
YJV43 |
YJLV43 |
XLPE insulated thick steel wire armored PE sheathed power cable |
|
Range of production
|
Cross sectional Voltage level area (mm2) Uo/U (KV) Number of cores |
0.6/1 |
1.8/3 |
Single core 1 |
1.5-1000 |
10-1000 |
Twin core 2 |
1.5-240 |
10-240 |
Triple core 3 |
1.5-300 |
10-300 |
Three big cores and two small cores 3+2 |
2.5-300 |
10-300 |
Notes:
1. Number of cores produced and cross section depend on cable models and voltages:
2. Warm water crosslinking and radiation crosslinking methods shall be adopted for 0.6/1KV and1.8/3KV.
Send Inquiry to This Supplier
You May Also Like
-
Opgw Power Optical Cable 12 Cores 24 Cores 36 Cores 48 CoresUS$ 1 - 1.1MOQ: 1000 Meters
-
Opgw Composite Overhead Optical Cable Opgw Power CableUS$ 1 - 1.1MOQ: 1000 Meters
-
2-72 Core High Voltage Opgw Overhead Composite Optical Fiber CableUS$ 1 - 1.1MOQ: 1000 Meters
-
Corrosion Resistant Overhead AACSR Conductor Bare Conductor China MannufacturerUS$ 1 - 1.1MOQ: 1000 Meters
-
ACSR/AS or ACSR/AW Overhead Bare ConductorUS$ 1 - 1.1MOQ: 1000 Meters
-
ACS Wire Bare Conductor Aluminum-Clad Steel Overhead Ground WireUS$ 1 - 1.1MOQ: 1000 Meters
-
AACSR Conductor Overhead Bare Conductor Transmission LineUS$ 1 - 1.1MOQ: 1000 Meters
-
NF EN 50182 AAAC ASTER Overhead Conductor Bare Conductor Transmission LineUS$ 1 - 1.1MOQ: 1000 Meters
-
AAC ASTM AS/NZS Overhead Conductor Bare Conductor Transmission LineUS$ 1 - 1.1MOQ: 1000 Meters
-
AS/NZS 3607 ACSR/GZ Aluminium Conductors, Galvanised Steel Reinforced Overhead Conductor Bare Conductor Transmission LineUS$ 1 - 1.1MOQ: 1000 Meters