Home > Instruments & Meters > Test Instrument > Test Machine > DC-LINK Capacitor Durability Test Rig

DC-LINK Capacitor Durability Test Rig

DC-LINK Capacitor Durability Test Rig photo-1
Negotiable MOQ: 1 Set (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Brand Name:
China Electronic Product Reliability and Environmental Testing Research Institute
Place of Origin:
China
Model Number:
59XX
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Brand Name China Electronic Product Reliability and Environmental Testing Research Institute
Place of Origin China
Model Number 59XX
Power Electronic
Usage Other

Characteristics of [DC-LINK Capacitor durability Test rig]

1. Can do durability test also can do charge and discharge test;

2. Voltage 0V off-regulation, over-voltage, over-current and other safety protection functions;

3. Test box with safety switch (flame retardant material);

4. Program control, automatic test process, parameters on the touch screen set and display, parameters power-off memory;

5. Automatic voltage regulation;

6. High power thyristor was used for discharge (maximum peak current 15kAp);

7. Can be customized according to customer needs non-standard.


Introduction of [DC-LINK Capacitor durability Test rig]

The durability test-bed of 5920C/2000 UF DC-Link capacitor is designed and manufactured according to the requirements of GB/T17702-2013 standard. It is controlled by Panasonic PLC programmable controller (FP-X L40R) and measured by two-way A / D conversion module embedded in PLC. All the parameters and the working state of the instrument are displayed and set on Taiwan's 7-inch color touch screen (MT6070iH). Humanized interface, easy to operate. The instrument also has automatic voltage regulation, automatic timing, test on-off, over-voltage and over-current short circuit protection, etc. Function to ensure the safety and reliability of the instrument. This instrument has the advantages of simple operation, good performance and high reliability. This equipment is suitable for DC capacitor durability test and impulse discharge test.


Technical parameters [DC-LINK Capacitor durability Test rig] (non-standard customizable)

Input characteristics:

1. Input voltage: AC 220V ±10%;

2. Input frequency: 50 Hz / 60 Hz;

3. Working environment: temperature: 10 ℃ ~ 30 ℃, humidity: ≤ 75% RH;

4. Power supply safe: 20A;

5. Device height: about 170 cm;

6. Color: Huawei grey.

Technical indicators:

1. Type of test: durability test and charge-discharge test;

2. Test voltage: DC 50 ~ 2000V, touch screen button setting;

3. Test voltage display accuracy (V): ±(3% ±3 words), touch screen display;

4. Durability test time setting: 0.1 ~ 9999.9 hours, can be set, after the end of the time will have a sound alarm, with power-off memory;

5. Its accuracy: ±1%;

6. Charge, discharge time setting: 1 ~ 999s, can be set;

7. Its accuracy: ±3%;

8. Number of impact tests: 1 ~ 9999 times, can be set;

9. Its accuracy: ±1 time;

10. Maximum charging current: 1A, (maximum charge current controlled by charging resistance);

11. Discharge device: (charge-discharge test): approximate short-circuit discharge; (maximum single capacity is 2000uF).

Auto Test Features:

1. Automatic pressure regulation;

2. Automatic timing, counting the number of charge and discharge;

3. Real-time monitoring of the test voltage, when the test voltage changes too large, the equipment can automatically adjust the voltage, and can set the voltage automatic adjustment range.

4. Voltage zero-volt on-off;

5. Over-current, over-voltage protection and other protection functions.

 

Maintenance and regular maintenance of [DC-LINK Capacitor durability Test rig]

Maintenance:

To prevent the occurrence of electric shock, do not lift the cover of the instrument. All parts inside the instrument need not be maintained by the user. If there is an abnormal condition in the instrument, please ask for maintenance from my laboratory. the attached lines and block diagrams are for reference only.

Regular maintenance:

At least once a year, the AC power supply and relevant accessories of input power line shall be carefully checked and checked to protect the safety of the user and the accuracy of the instrument....

 

For more information about products, please contact us and visit the company.

Address: Tianhui Road, Wisdom City, Tianhe District, Guangzhou

Tel: 86-20-37896688

Fax:86-20-37896699

Mobile phone: 86-13711272581,Miss Liu

Web site:


Product Tags: Capacitor durability test , Capacitor durability test-bed , The DC LINK capacitor durability

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer
Year Established
2017
Annual Export Value
Below US$1 Million
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market

Recommended Categories

Explore top categories and find suppliers for your specific needs