HSA2030B,3.2g Built-in Tracking Generator Portable Spectrum Analyzer
HSA2030B,3.2g Built-in tracking generator portable spectrum analyzer
- 5.7 inch highlight color display
- Frequency range: 9KHz-3GHz (tunable to 9KHz) AC Coupled
- Built-in 3GHz tracking generator
- Optimal sensitivity: -161dBm
- 7800mAh Li-ion battery for over 4 hours continuous operation
- PC software can achieve the management and storage of testing data
- Integration USB_Host & USB_Device,support USB flash disk memory,optional WIFI/LAN
| Model | HSA2030A | HSA2030B | |
| Frequency Characteristic | |||
| Frequency Range | 9KHz~3.2GHz AC Coupled | 9KHz~3.2GHz AC Coupled 5M~3.2GHz TG | |
| Frequency Resolution | 1Hz | ||
| Reference Frequency | 10MHz | ||
| Frequency Readout Accuracy | ±(frequency indication*frequency reference uncertainty +1%*span +20%RBW +marker resolution +1Hz) | ||
| Frequency aging rate | ±1ppm/year (0°C~50°C,Reference is 25°C) | ||
| Temperature stability | ±1ppm/year | ||
| Marker Resolution | (Frequency span)/(number of sweep points-1) | ||
| Resolution Bandwidth(RBW) | |||
| Filter Bandwidth(RBW) | 10Hz to 1MHz,1-3-10 sequence | ||
| Accuracy | ±5% RBW=10Hz~1MHz nominal | ||
| Video Bandwidth(VBW) | 1Hz to 1MHz,1-3-10 sequence(-3dB bandwidth) | ||
| Video Bandwidth Accuracy | ±10% VBM=1Hz~1MHz nominal | ||
| Displayed Average Noise Level (normalized to1Hz) | |||
| Preamp off | 9K~1MHz | -108dBm,typical -127dBm | |
| 1MHz ~10MHz | -128dBm,typical -146dBm | ||
| 10MHz ~500MHz | -142dBm,typical -146dBm | ||
| 500MHz ~2.5GHz | -141dBm,typical -145dBm | ||
| 2.5GHz ~3.2GHz | -140dBm,typical -144dBm | ||
| Preamp on | 9K~1MHz | -131dBm,typical -150dBm | |
| 1MHz ~10MHz | -148dBm,typical -163dBm | ||
| 10MHz ~500MHz | -161dBm,typical -164dBm | ||
| 500MHz ~2.5GHz | -159dBm,typical -162dBm | ||
| 2.5GHz ~3.2GHz | -158dBm,typical -161dBm | ||
| SSB Phase Noise (20°C~30°C, 500MHz Central Frequency) | |||
| Carrier Offset | 10K | < -92 dBc/Hz, typical -95 dBc/Hz | |
| 30K | < -93 dBc/Hz, typical -96 dBc/Hz | ||
| 100K | < -95 dBc/Hz, typical -97 dBc/Hz | ||
| 1MHz | < -117 dBc/Hz, typical -119 dBc/Hz | ||
| Sweep Time | |||
| Sweep Range | Span >100Hz | 2ms to 1000s | |
| Span=0Hz | 600ns to 200s | ||
| Sweep Mode | Continuous, single | ||
| Trigger Source | Free run; video; external | ||
| Trigger slope | Selectable positive or negative edge | ||
| Trigger delay | Span =0Hz | ±12ms to ±12s nominal | |
| Frequency Counter | |||
| Counter Resolution | 1Hz | ||
| Accuracy | ± (marker frequency×frequency reference uncertainty+counter resolution) | ||
| Level Display Range | |||
| Log Scale and Units | 1 to 10 dB/divisions in 1, 2, 5, 10 dB steps, 10 divisions displayed | ||
| Linear Scale and Units | 0 to 100%,10 divisions displayed | ||
| Scale Unit | dBm,dBmV,dBuV,Watts,Volts | ||
| Sweep (Trace) Points | 461 | ||
| Number of Markers | 4 | ||
| Detectors | Normal, positive peak, dample, negative peak, RMS | ||
| Number of Traces | 4 | ||
| Trace Functions | Clear/write, maximum hold, minimum hold, average, check,close | ||
| Level Measurement Error |
±1.5dB(excluding input VSWR mismatch) 20~30°C,peak detector, preamplifier off, input signal -50dBm to 0dBm |
||
| Reference Level | |||
| Second Harmonic Distortion(SHI) |
<65dBc,50MHz~3GHz (Mixer level -30dBm,attenuator =0dB,preamp off,20°C~30°C) |
||
| TOI | 50~300MHz |
+8dBm,Third-order intermodulation products:2 x -20dBm; frequency separation 100KHz:attenuation = 0dB; preamp off,20°C~30°C |
|
| 300MHz~3.2GHz | +10dBm | ||
| Input Related Spurious | <-75dBc,(input mixer = -30dBm) | ||
| Inherent Residual Response |
<-90dBm,typical -98dBm (Input terminated and 0 dB RF attenuation, preamplifier off) |
||
| RF Input VSWR | 10MHz to 3.2GHz | <1.5:1, nominal Attenuator setting 10~20dB | |
| 10MHz Reference/External Trigger Input | |||
| Reference Iinput Frequency | 10MHz | ||
| Reference Input Amplitude | 0~10dBm | ||
| Trigger Voltage | 5V TTL level | ||
| Connector and Output Impendence | N female;(50Ω) | ||
| Gennral Characteristic | |||
| Language | English,Chinese,Chinese Traditional | ||
| Display | 5.7 inch,640*480 resolution,64M color LCD display | ||
| Dimensions | 260mm* 220mm*75mm | ||
| Weight | 2.9kg(with battery),2.6kg(without battery) | ||
500MHz ~2.5GHz -141dBm,typical -145dBm
2.5GHz ~3.2GHz -140dBm,typical -144dBm
Preamp on 9K~1MHz -131dBm,typical -150dBm
1MHz ~10MHz -148dBm,typical -163dBm
10MHz ~500MHz -161dBm,typical -164dBm
500MHz ~2.5GHz -159dBm,typical -162dBm
2.5GHz ~3.2GHz -158dBm,typical -161dBm
SSB Phase Noise (20°C~30°C, 500MHz Central Frequency)
Carrier Offset 10K < -92 dBc/Hz, typical -95 dBc/Hz
30K < -93 dBc/Hz, typical -96 dBc/Hz
100K < -95 dBc/Hz, typical -97 dBc/Hz
1MHz < -117 dBc/Hz, typical -119 dBc/Hz
Sweep Time
Sweep Range Span >100Hz 2ms to 1000s
Span=0Hz 600ns to 200s
Sweep Mode Continuous, single
Trigger Source Free run; video; external
Trigger slope Selectable positive or negative edge
Trigger delay Span =0Hz ±12ms to ±12s nominal
Frequency Counter
Counter Resolution 1Hz
Accuracy ± (marker frequency×frequency reference uncertainty+counter resolution)
Level Display Range
Log Scale and Units 1 to 10 dB/divisions in 1, 2, 5, 10 dB steps, 10 divisions displayed
Linear Scale and Units 0 to 100%,10 divisions displayed
Scale Unit dBm,dBmV,dBuV,Watts,Volts
Sweep (Trace) Points 461
Number of Markers 4
Detectors Normal, positive peak, dample, negative peak, RMS
Number of Traces 4
Trace Functions Clear/write, maximum hold, minimum hold, average, check,close
Level Measurement Error "±1.5dB(excluding input VSWR mismatch)
20~30°C,peak detector, preamplifier off, input signal -50dBm to 0dBm"
Reference Level
Second Harmonic Distortion(SHI) "<65dBc,50MHz~3GHz
(Mixer level -30dBm,attenuator =0dB,preamp off,20°C~30°C)"
TOI 50~300MHz "+8dBm,Third-order intermodulation products:2 x -20dBm;
frequency separation 100KHz:attenuation = 0dB;
preamp off,20°C~30°C"
300MHz~3.2GHz +10dBm
Input Related Spurious <-75dBc,(input mixer = -30dBm)
Inherent Residual Response "<-90dBm,typical -98dBm
(Input terminated and 0 dB RF attenuation, preamplifier off)"
RF Input VSWR 10MHz to 3.2GHz <1.5:1, nominal Attenuator setting 10~20dB
10MHz Reference/External Trigger Input
Reference Iinput Frequency 10MHz
Reference Input Amplitude 0~10dBm
Trigger Voltage 5V TTL level
Connector and Output Impendence N female;(50Ω)
Gennral Characteristic
Language English,Chinese,Chinese Traditional
Display 5.7 inch,640*480 resolution,64M color LCD display
Dimensions 260mm* 220mm*75mm
Weight 2.9kg(with battery),2.6kg(without battery)
Send Inquiry to This Supplier
You May Also Like
-
Next-Gen Digital OES Analyzer | Multi-Element Detection Spark Spectrometer for Non-Ferrous & Ferrous Metals | ISO StandardsUS$ 16500 - 25000MOQ: 1 Set
-
Digital Portable Spectrum Analyzer for LED TestingUS$ 1,500 - 2,000MOQ: 1 Set
-
752 UV-VIS SPECTROPHOTOMETERUS$ 1,000 - 1,200MOQ: 1 Set
-
Visible Spectrophotometer 721/722NegotiableMOQ: 1 Set
-
Supply of Heavy Metal Spectrum Analyzer for Leather and Fur, Mingrui Icp700t Model, Detector for Harmful Substances in Leather and Fur ProductsUS$ 45846.15 - 50461.54MOQ: 1 Unit
-
Tuohe Ultra-Micro Spectrophotometer UV Tnano-800 Laboratory Photometer for 0.5-2ul Sample Detection of Nucleic Acids, Proteins, and Cell SolutionsNegotiableMOQ: 1 Piece
-
I-CHEQX GEN 3 Handheld XRFNegotiableMOQ: 1 Piece
-
5-1000um Blacked Pinhole Array With Different ShapesUS$ 10 - 30MOQ: 1 Piece
-
NANBEI Digital Single Beam NV-T5C UV Visible SpectrophotometerNegotiableMOQ: 1 Set
-
T-6 /T-6m UV-Visible SpectrophotometerUS$ 300 - 1,500MOQ: 1 Set