Home > Products > Mining & Rubber Cable,antiflaming cabtyre wire > 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 Welding Cable
16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 Welding Cable
- 500 Kilometer / Kilometers per Month
- Qingdao
- T/T L/C D/P D/A Credit Card PayPal
- Mooring rope cable
- Manufacturer of waterproof gas electric composite cable for air ducts, specialized cable for underwater divers
- The difference between different types of automotive cables and selection advice
- China manufacturer Communicate cable RVVP 4*0.3mm2 for power generation
- IEC62196-2 mode 3 16A single-phase electric vehicle charging process
- Automotive high-voltage cables with protection class IP67 characteristics
Product Details
Place of Origin: | Henan, China | Brand Name: | Jinshui | Model Number: | welding cable |
Insulation Material: | Rubber | Type: | Low Voltage | Application: | Industrial |
Conductor Material: | Copper | Jacket: | Rubber |
Product Description
Specifications
16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 Welding CableRubber insulated or silicone insulated
Rubber insulated copper wire
ISO
16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 Welding Cable
Application of welding cable
Welding Cables are flame retardant, oil resistant, resilient, resists compression cuts and abrasion,
durable, and survives rough handling. Designed for use as arc welding leads from the secondary side of the power
source, typical of welders and welding generators. Not for primary voltage.
Construction of welding cable
Welding Cables are manufactured using annealed rope-stranded bare copper conductor as per ICEA
S-75-381. A paper tape separates the conductor insulation. A medium-duty EPR jacket is extruded onto the
cable. EP or Hypalon jackets are available. 600 volt spark tested.
Standard of welding cable
ASTM B-3 ASTM B1732, ICEA S-175-381, IEC 254-1.
Specification of welding cable
Medium Duty jacket made accordance with ICEA S-75-381 - Portable and Power Feeder Cables for Use in
Mines and Similar Locations or IEC 245-1
600 Volt Spark tested
Technical data of welding cable
Conductor Nominal Section (mm2) | Conductive Core | Thickness of Section Sheath (mm) | Average Outer Diameter (mm2) | 200C Conductor Resistance≤(Ω/km) | |
Number/Diameter of Core(mm) | Min | Max | |||
10 | 322/0.20 | 1.8 | 7.5 | 9.7 | 1.91 |
16 | 513/0.20 | 2.0 | 9.2 | 11.5 | 1.16 |
25 | 798/0.20 | 2.0 | 10.5 | 13.0 | 0.758 |
35 | 1121/0.20 | 2.0 | 11.5 | 14.5 | 0.536 |
50 | 1596/0.20 | 2.2 | 13.5 | 17.0 | 0.379 |
70 | 2214/0.20 | 2.4 | 15.0 | 19.5 | 0.268 |
95 | 2997/0.20 | 2.6 | 17.0 | 22.0 | 0.198 |
120 | 1702/0.30 | 2.8 | 19.0 | 24.0 | 0.161 |
150 | 2135/0.30 | 3.0 | 21.0 | 27.0 | 0.129 |
185 | 1443/0.40 | 3.2 | 22.0 | 29.0 | 0.106 |
Contact Us
- Henan Jinshui Cable Group Co., Ltd.
- Contact nameJINSHUI JS
- Phone086-371-67849797
- AddressNo. 82, West Part of Kexue Avenue, High and New Technology Development Zone, Zhengzhou City, Henan Province. China Zhengzhou,Henan
- Application of high-voltage cables for locomotive equipment
- Manufacturing connection technology for automotive battery systems
- Vehicle High Voltage Cable Connection Test Results
- Automotive high voltage cable 35 square role
- Standard requirements for types of electric vehicle charging cables - Mode III
- Cables for automotive motor energy storage system applications
- Liquid-cooled charging systems applied to electric vehicle scenarios
- IEC 60502-2,GB/T 12706.2,GB/T 12706.3 IEC 60502-2 XLPE insulated,copper tape screened,unarmored power cable for voltages from 6kV up to 35kV
- IEC 60502-2,GB/T 12706.2,GB/T 12706.3 IEC 60502-2 XLPE insulated,copper tape screened,steel tape armored power cable for voltages from 6kV up to 35kV
- IEC 60502-2 IEC 60502-2 XLPE insulated,steel wire armored power cable for voltages from 6kV up to 35kV
- IEC 60502-1,GB/T 12706.1 0.6/1kV IE 60502-1 PVC insulated and sheathed power cable
- IEC 60502-1 0.6/1kV IEC 60502-1 XLPE insulated,PVC sheathed power cable
- EC 60502-1 0.6/1kV IEC 60502-1 XLPE insulated,PVC sheathed,steel tape armoured power cable
- IEC 60502-1 0.6/1kV IEC 60502-1 PVC insulated and sheathed,steel tape armoured power cable
- IEC 60502-1 0.6/1kV IEC 60502-1 XLPE insulated,PVC sheathed,steel wires armoured power cable
- IEC 60502-1 0.6/1kV IEC 60502-1 PVC insulated,PVC sheathed,steel wire armoured power cable
- AAC/XLPE,AAC/HDPE,AAAC/XLPE ,AAAC/HDPE Single-core aerial insulated cables for rated voltage of 10kV
- AAC/XLPE,AAAC/XLPE Aerial Single-core Insulated Cables with Rated Voltage 1kV or Lower
- Energy Storage Harness Technology
- Know the EV charging FAQs by understanding
- 95mm2 Vehicle Cable Applications for EVRP-125
- Introduction of material XLPE cable application characteristics
- Aerial Bundled Cable AAC/XLPE+AAC Duplex Service Drop Cables with Rated Voltage 600V to 1000V
- Introduction to cable production process
Popular Searches
Recommended Products
- FOXBORO FBMSVH Control card module
- FOXBORO FBMSVL Multi port serial card
- ABB XVC770BE102 3BHE021083R0102 Thermal dispersion technology flow meter
- ABB XVC770AE 3BHE006414R0001 Servo Driver
- ABB PFEA113-65 3BSE050092R65 Dual expansion port module
- ABB LTC391AE01 HIEE401782R0001 connecting module
- ABB DSAI 130A 3BSE018292R1 Digital input/output module
- GE SR489-P5-HI-A20-E Protection Relay
- VIBRO-METER VM600 RPS6U 200-582-500-013 Vibration monitoring and control system
- HONEYWELL SPS5710 51199929-100 Power supply module
- GE IS210BPPBH2CAA Digital expansion module
- GE IS200TSVCH2AED MRP246517 Digital I/O module
Find Similar Products By Category
- Electrical Equipment & Supplies > Wires, Cables & Cable Assemblies > Electric Cable
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
JINSHUI JS
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-