N2XSBY (YJV62) 3.6-6(7.2)kV

N2XSBY (YJV62) 3.6-6(7.2)kV photo-1

Product Spotlights

Medium voltage cables for distribution networks, they are suitable for laying indoor, tunnel, cables trench and underground, it is able to bear external mechanical forces, but unable to bear heavy pulling force, it widely used in transformer stations, electric power plants and industrial plants.
Negotiable MOQ: 3000 Meters (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Certification:
ISO9001
Application:
Overhead
Payment & Shipping
Payment Methods:
Port of Shipment:
Shanghai
Delivery Detail:
7 days
Certification ISO9001
Application Overhead

Application
Medium voltage cables for distribution networks, they are suitable for laying indoor, tunnel, cables trench and underground, it is able to bear external mechanical forces, but unable to bear heavy pulling force, it widely used in transformer stations, electric power plants and industrial plants.

Construction
● Conductor: Copper, class 2, circular compacted conductors 
● Conductor screen :Non-metallic,semi-conducting compound
● Insulation: Cross-Linked polyethylene XLPE
● Insulation screen: Non-metallic,semi-conducting compound
● Metallic screen: Copper tape
● Inner sheath: Polyvinyl chloride PVC
● Armour: Non-magnetic steel tape  
● Outer sheath: Polyvinyl chloride PVC

Chaircteritics
Good electrical and mechanical properties. Minimal dielectric loss, high insulation resistance. The PVC outer sheath allows adequate resistance to grease, oil and abrasion. 

Specification
IEC 60228 Conductors of Insulate Cables.
IEC 60502-2 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) - Part 2: Cables for Rated Voltages of 6kV(Um=7.2kV) and 30kV(Um=36kV) 

High reliability

Super high pressure

Less maintenance

Technical Parameter

IEC 60502-2

No. of Cores and Nominal Cross Section Min. Number of Wires Nominal Insulation Thickness Nominal Copper Tape Thickness Nominal Steel Tape Thickness Nominal
Sheath Thickness
Approx. Overall Diameter Approx. Weight Max. D.C.Resistance of Conductor
at 20℃
mm² No. mm mm mm mm mm kg/km Ω/km
  3.6/6(7.2)kV
1X25 6 2.5 0.12 0.20 1.6 20.2 728 0.727
1X35 6 2.5 0.12 0.20 1.6 21.2 849 0.524
1X50 6 2.5 0.12 0.20 1.7 22.5 1006 0.387
1X70 12 2.5 0.12 0.20 1.7 24.2 1252 0.268
1X95 15 2.5 0.12 0.20 1.8 26.2 1559 0.193
1X120 18 2.5 0.12 0.20 1.8 27.4 1819 0.153
1X150 18 2.5 0.12 0.20 1.9 29.1 2130 0.124
1X185 30 2.5 0.12 0.20 1.9 30.8 2524 0.0991
1X240 34 2.6 0.12 0.20 2.0 33.5 3130 0.0754
1X300 34 2.8 0.12 0.50 2.2 37.7 4161 0.0601
1X400 53 3.0 0.12 0.50 2.3 41.0 5109 0.0470
1X500 53 3.2 0.12 0.50 2.4 45.2 6290 0.0366
1X630 53 3.2 0.12 0.50 2.5 49.3 7813 0.0283


Product Tags: N2XSBY YJV62 3.6/6(7.2)kV non-magnetic armored medium voltage cable , Copper conductor XLPE insulated stainless steel tape armored underground distribution cable , IEC 60502 3.6-7.2kV substation industrial plant power transmission cable

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Business Type
Manufacturer
Year Established
2009
Factory Size
50,000-100,000 square meters
Annual Export Value
Above US$100 Million