Medium Voltage Power Cables ICEA S-93-639
Product Spotlights
Sunlight, oil and moisture resistant, supports laying in ducts, trays, direct burial for industrial & utility power distribution.
Application
These cables are used in primary distribution network systems in residential, commercial and industrial areas. They can be used in conduit pipes, underground ducts or directly buried.
Construction
● Conductor :Copper or aluminum, circular compressed or compacted stranded conductors
● Conductor screen: Non-metallic,semi-conducting compound
● Insulation: 100% and 133% and 173% insulation level, cross-linked polyethylene XLPE or tree retardant cross-linked polyethylene insulation(TRXLPE)
● Insulation screen:Non-metallic,semi-conducting compound
● Metallic screen: Copper tape
● Outer sheath: Sunlight resistant, Polyvinyl chloride PVC or Polyethylene (PE) or Polyolefin (PO)
Specification
ASTM B 8 Standard Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft
ASTM B 231 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B 496 Compact Round Concentric-Lay-Stranded Copper Conductors.
ASTM B 400 Compact Round Concentric-Lay-Stranded Aluminum 1350 Conductors.
ANSI/NEMA WC 74/ICEA S-93-639 5-46kV Shielded Power Cable for Use in the Transmission and Distribution of Electric Energy
UL1072 Medium Voltage Power Cable
Chaircteritics
● Maximum conductor temperature in normal operation: 90˚C.
● Emergency Overload Temperature: Shall not exceed 130˚C.
● Short Circuit Temperature ( 5 seconds maximum duration ): Shall not exceed 250˚C.
● Product manufacturing options:
● Blocking elements against the penetration of water in the metallic part for humid and wet environments.
High reliability
Super high pressure
Less maintenance
Technical Parameter
15 kV Power Cable CU(AL)/XLPE/CTS/PVC25 kV Power Cable CU(AL)/XLPE/CTS/PVC35 kV Power Cable CU(AL)/XLPE/CTS/PVC
| Conductor | 100% Insulation Level | 133% Insulation Level | ||||||||
| Size | Area | Nominal Diameter | Nominal Insulation Thickness | Nominal Sheath Thickness | Approx. Overall Diameter | Approx. Weight | Nominal Insulation Thickness | Nominal Sheath Thickness | Approx. Overall Diameter | Approx. Weight |
| AWG/kcmil | mm² | mm | mm | mm | mm | kg/km | mm | mm | mm | kg/km |
| Copper Conductor | ||||||||||
| 2 | 33.6 | 6.81 | 4.45 | 1.65 | 23.5 | 821 | 5.59 | 2.03 | 27.0 | 983 |
| 1 | 42.4 | 7.59 | 4.45 | 1.65 | 24.3 | 926 | 5.59 | 2.03 | 27.7 | 1093 |
| 1/0 | 53.5 | 8.53 | 4.45 | 2.03 | 26.2 | 1108 | 5.59 | 2.03 | 28.7 | 1229 |
| 2/0 | 67.4 | 9.55 | 4.45 | 2.03 | 27.2 | 1270 | 5.59 | 2.03 | 29.7 | 1394 |
| 3/0 | 85 | 10.7 | 4.45 | 2.03 | 28.3 | 1470 | 5.59 | 2.03 | 30.8 | 1598 |
| 4/0 | 107 | 12.1 | 4.45 | 2.03 | 29.7 | 1719 | 5.59 | 2.03 | 32.2 | 1853 |
| 250 | 127 | 13.2 | 4.45 | 2.03 | 30.8 | 1935 | 5.59 | 2.03 | 33.3 | 2073 |
| 350 | 177 | 15.6 | 4.45 | 2.03 | 33.2 | 2479 | 5.59 | 2.03 | 35.7 | 2626 |
| 500 | 253 | 18.7 | 4.45 | 2.03 | 36.3 | 3278 | 5.59 | 2.03 | 38.8 | 3437 |
| 750 | 380 | 23.1 | 4.45 | 2.03 | 40.7 | 4583 | 5.59 | 2.03 | 43.2 | 4758 |
| 1000 | 507 | 26.9 | 4.45 | 2.03 | 44.9 | 5881 | 5.59 | 2.79 | 49.2 | 6266 |
| 1250 | 633 | 31.8 | 5.59 | 2.79 | 54.1 | 7631 | 5.59 | 2.79 | 54.1 | 7631 |
| Aluminum Conductor | ||||||||||
| 2 | 33.6 | 6.81 | 4.45 | 1.65 | 23.5 | 607 | 5.59 | 2.03 | 27.0 | 770 |
| 1 | 42.4 | 7.59 | 4.45 | 1.65 | 24.3 | 657 | 5.59 | 2.03 | 27.7 | 824 |
| 1/0 | 53.5 | 8.53 | 4.45 | 2.03 | 26.2 | 769 | 5.59 | 2.03 | 28.7 | 889 |
| 2/0 | 67.4 | 9.55 | 4.45 | 2.03 | 27.2 | 843 | 5.59 | 2.03 | 29.7 | 967 |
| 3/0 | 85 | 10.7 | 4.45 | 2.03 | 28.3 | 930 | 5.59 | 2.03 | 30.8 | 1058 |
| 4/0 | 107 | 12.1 | 4.45 | 2.03 | 29.7 | 1039 | 5.59 | 2.03 | 32.2 | 1173 |
| 250 | 127 | 13.2 | 4.45 | 2.03 | 30.8 | 1129 | 5.59 | 2.03 | 33.3 | 1267 |
| 350 | 177 | 15.6 | 4.45 | 2.03 | 33.2 | 1351 | 5.59 | 2.03 | 35.7 | 1499 |
| 500 | 253 | 18.7 | 4.45 | 2.03 | 36.3 | 1666 | 5.59 | 2.03 | 38.8 | 1825 |
| 750 | 380 | 23.1 | 4.45 | 2.03 | 40.7 | 2167 | 5.59 | 2.03 | 43.2 | 2342 |
| 1000 | 507 | 26.9 | 4.45 | 2.03 | 44.9 | 2669 | 5.59 | 2.79 | 49.2 | 3054 |
| 1250 | 633 | 31.8 | 5.59 | 2.79 | 54.1 | 3612 | 5.59 | 2.79 | 54.1 | 3612 |
Send Inquiry to This Supplier
You May Also Like
-
NAYY (VLV)NegotiableMOQ: 3000 Meters
-
NA2XBY (YJLV22) 0.6-1kVNegotiableMOQ: 3000 Meters
-
NA2XRY (YJLV32) 0.6-1kVNegotiableMOQ: 3000 Meters
-
NA2XY (YJLV) 0.6-1kVNegotiableMOQ: 3000 Meters
-
NAYBY (VLV22)NegotiableMOQ: 3000 Meters
-
NAYRY (VLV32)NegotiableMOQ: 3000 Meters
-
N2XBY (YJV22) 0.6-1kVNegotiableMOQ: 3000 Meters
-
N2XRY (YJV32) 0.6-1kVNegotiableMOQ: 3000 Meters
-
N2XY (YJV) 0.6-1kVNegotiableMOQ: 3000 Meters
-
NYBY (VV22)NegotiableMOQ: 3000 Meters