Fire Resistant Cable Manufacturer | IEC 60331 & BS 6387 Compliant | 1.5mm²-400mm²
Product Spotlights
Low Smoke Zero Halogen (LSZH) Fire Cable | Protecting People, Not Just Property
1100°C for 6 Hours – The Ultimate Test for Fire Survival Cables
XLPE + Mica Tape + LSZH Multi-Layer Design | Built for High-Rise & Tunnel Projects
Fire Resistant Cable Manufacturer | IEC 60331 & BS 6387 Compliant | 1.5mm²-400mm²
CABLE CONSTRUCTION
Conductors: 23AWG solid bare copper.
Insulation: HDPE .
Twinning: Two coloured insulated conductors twisted together to form a pair.
Inner Sheath: Flame retardant, low smoke and halogen-free polyolefin, coloured black.
Armouring:
cwb: copper Wire Braid
swb: Steel Wire Braid
swa: Steel Wire Armour
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655:section 2.6 can be offered.) Cat6 F/UTP: These cables have collective shielding of aluminium/Polyester tape with drain wire.
Cat6 SF/UTP: These cables have double collective shieldings of aluminium/Polyester tape & copper wire braid with drain wire.
FIRE PERFORMANCE
| Flame Retardance (Single Vertical Wire Test) | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
| Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
| Halogen Free | IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* |
| No Corrosive Gas Emission | IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* |
| minimum Smoke Emission | IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
| No Toxic gases | NES 02-713; NF C 20-454 |
Note: Asterisk * denotes superseded standard.
Why Fire Resistant Cables Matter More Than Ever
In high-rise buildings, tunnels, hospitals, and emergency systems—circuit integrity during a fire isn’t optional. It’s a life-safety requirement.
Our BS 6387 CWZ approved Fire Resistant Cables are engineered to keep critical systems operational when it matters most:
🔥 90-180 minutes circuit integrity at up to 950°C
👉 Low Smoke Zero Halogen (LSZH) – minimal toxic gas & smoke emission
🛡️ Mica Glass Tape + XLPE/LSZH multi-layer fire barrier design
✅ Certified to BS 6387 CWZ, IEC 60331, IEC 60332, IEC 61034
Available in single-core & multi-core, 1.5mm² – 400mm², with or without SWA armouring.
Send Inquiry to This Supplier
You May Also Like
-
Intrinsically Safe Explosion-proof Instrument Cable | ATEX Hazardous Area Low-smoke, Halogen-free, Fire-resistant Shielded Instrument Signal CableUS$ 2MOQ: 1000 Meters
-
BS 6724 Standards Armoured Power Cables, 600/1000VNegotiableMOQ: 1000 Meters
-
BS EN50288-7 Standards Fire Retardant Instrumentation Cables RE-Y(St)YUS$ 2MOQ: 1000 Meters
-
Fire Resistant CAT5e CWB/SWB/SWA Armoured Data CablesNegotiableMOQ: 1000 Meters
-
Fire Resistant CAT6 CWB/SWB/SWA Armoured Data CablesNegotiableMOQ: 1000 Meters
-
Fire Resistant CAT6A SWB Armoured Data CablesNegotiableMOQ: 1000 Meters
-
Fire Resistant RS 485 Databus CablesNegotiableMOQ: 1000 Meters
-
CPR CablesNegotiableMOQ: 1000 Meters
-
BS EN 50288-7 Standard Fire Resistant Overall Screened Instrumentation Cables (Multicore)RE-2X(St)H...CIUS$ 2MOQ: 1000 Meters
-
BS6387 CWZ Standard Fire Resistant Control Cable FFX200 07SZ1-RNegotiableMOQ: 1000 Meters