Fire Resistant CAT5e CWB/SWB/SWA Armoured Data Cables
Fire Resistant CAT5e CWB/SWB/SWA Armoured Data Cables
FFX-CAT5eU/UTP4P24FR CWB/SWB/SWA
FFX-CAT5ef/UTP4P24FR CWB/SWB/SWA
FFX-CAT5esf/UTP4P24FR CWB/SWB/SWA
APPLICATION
Cat5E is a cable standard for Gigabit Ethernet and other network protocol, suitable for basic voice and data installations up to 100 MHz. In addition, these cables can be offered with copper wire braid armoured & flame retardant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable.
STANDARDS
ISO/IEC 11801, EN 50173, ANSI/TIA/EIA 568
FIRE PERFORMANCE
| Circuit Integrity | IEC 60331-23; BS 6387 CWZ (Optional) |
|---|---|
| Flame Retardance (Single Vertical Wire or cable test) | IEC 60332-1-2; EN 60332-1-2 |
| Halogen Free | IEC 60754-1; EN 50267-2-1 |
| No Corrosive Gas Emission | IEC 60754-2; EN 50267-2-2 |
| Minimum Smoke Emission | IEC 61034-2; EN 61034-2 |
CABLE CONSTRUCTION
Conductors: 24AWG solid bare copper.
Insulation: HDPE+Fire barrier.
Twinning: Two coloured insulated conductors twisted together to form a pair.
Overall Fire Barrier: optional.
Inner Sheath: Thermoplastic LSZH compound.
Armouring:
CWB: Copper Wire Braid
SWB: Steel Wire Braid
SWA: Steel Wire Armour
Outer Sheath: Halogen-free flame retardant thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655:section 2.6 can be offered).
Outer Sheath Option: UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.
Cat5EF/UTP: These cables have collective shielding of Aluminium/polyester tape with drain wire.
Cat5ESF/UTP: These cables have double collective shieldings of Aluminium/polyester tape & copper wire braid.
Physical AND THERMAL PROPERTIES
Temperature range: -30°C - +75°C
Minimum bending radius during installation (mobile state): 8 x Overall Diameter
Minimum bending radius during operation (fixed state): 4 x Overall Diameter
Send Inquiry to This Supplier
You May Also Like
-
BS6387 CWZ Standard Fire Resistant Control Cable FFX200 07SZ1-RNegotiableMOQ: 1000 Meters
-
BS EN 50288-7 Standard Fireguard Flame Retardant Individual and Overall Screened Instrumentation Cables (Multipair)NegotiableMOQ: 1000 Meters
-
600/1000V,PVC Insulated Cables According to IEC 60502-1 Standard Two Core(armoured)NegotiableMOQ: 1000 Meters
-
PVC Insulated Cables According to IEC 60502-1 Cables 600/1000VNegotiableMOQ: 1000 Meters
-
Low Voltage Low Smoke Zero Halogen Fire Resistant Armoured CableNegotiableMOQ: 1000 Meters
-
Instrument Cable RE-2X(C)Y Signal Transmission CableNegotiableMOQ: 1000 Meters
-
Instrument Cable RE-2X (C) H Shielded Signal CableNegotiableMOQ: 1000 Meters
-
Cu/X-HF-110/HFS-110-Tp Flexible Multicore 110°C Low Fire Hazard CableNegotiableMOQ: 1000 Meters
-
N2XH-FE 180/E 90security Cable, Halogen-free, 0,6/1 kVNegotiableMOQ: 1000 Meters
-