Side-Operated Indoor Load Break Switch FLN36 Series 11kV 33kV SF6 Insulated

Side-Operated Indoor Load Break Switch FLN36 Series 11kV 33kV SF6 Insulated photo-1
Side-Operated Indoor Load Break Switch FLN36 Series 11kV 33kV SF6 Insulated photo-2
Side-Operated Indoor Load Break Switch FLN36 Series 11kV 33kV SF6 Insulated photo-3
Side-Operated Indoor Load Break Switch FLN36 Series 11kV 33kV SF6 Insulated photo-4

Product Spotlights

The FLN36 Series Side-Operated Indoor Load Break Switch provides reliable load isolation for 11kV and 33kV power systems. Its key selling points include sealed SF6 gas insulation for enhanced safety and compact design, a convenient side-operated mechanism for easy panel integration, robust construction for long mechanical life with minimal maintenance, and flexible configurations to suit various industrial and utility applications. Manufactured with a focus on quality and backed by international standards compliance.
US$ 350 ≥10 Units
Key Specifications
Get Latest Price
Rated Voltage:
11kV, 33kV
Insulation Medium:
SF6 Gas
Operation Type:
Side-Operated
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Rated Voltage 11kV, 33kV
Insulation Medium SF6 Gas
Operation Type Side-Operated
Installation Environment Indoor
Breaking Capacity Rated load current breaking
Contact Material Copper alloy
Mounting Type Fixed or withdrawable
Application Power distribution, industrial plants
Mechanical Life >3000 operations
Standard Compliance IEC, GB standards

As a specialized manufacturer of high-voltage electrical equipment, Jinhua Dika Electrical Equipment Co., Ltd. leverages its expertise in switchgear design to present the FLN36 Series Side-Operated Indoor Load Break Switch. Engineered for reliability and safety in medium-voltage power distribution networks, this SF6-insulated switch provides a robust solution for isolating and switching loads under normal and fault conditions. Our commitment to precision manufacturing and rigorous quality control ensures each unit delivers consistent performance, meeting the demanding requirements of utilities, industrial facilities, and commercial power systems worldwide.

The FLN36 Series is designed for operational efficiency and long service life. Its key features and benefits include:

  • Enhanced Safety: The SF6 gas insulation provides excellent dielectric strength and arc-quenching properties, significantly reducing the risk of internal flashovers and enhancing personnel safety. The sealed tank design minimizes external environmental influences.
  • Reliable Load Breaking: Engineered to reliably make and break rated load currents, facilitating safe isolation of circuit sections for maintenance or reconfiguration without requiring a full system shutdown.
  • Convenient Side Operation: The side-operated mechanism allows for easier installation and integration into switchgear panels or cubicles, optimizing space utilization and improving accessibility for operators.
  • Low Maintenance: The sealed SF6 system and robust mechanical design result in minimal maintenance requirements, reducing total cost of ownership over the switch's lifespan.
  • Flexible Configuration: Available for both 11kV and 33kV systems, the FLN36 can be configured in various pole arrangements (3-pole, 4-pole) to suit specific application needs.

Technical Specifications Overview:

Parameter Specification
Rated Voltage (Ur) 11kV, 33kV
Rated Frequency 50Hz / 60Hz
Rated Normal Current (In) 630A, 1250A, 2000A (Customizable)
Insulation Medium SF6 Gas
Short-Time Withstand Current (Ik) 25kA / 31.5kA for 3s
Mechanical Life ≥3000 operations
Operating Mechanism Manual, side-operated (motorized option available)
Ambient Temperature Range -25°C to +40°C
Degree of Protection (IP Code) IP3X (for indoor compartments)

Application Advantages for Your Project:

  • For Utility Substations: Provides a visible isolation point for feeder circuits, enhancing operational safety during switching and maintenance activities. Its compact indoor design saves valuable substation space.
  • For Industrial Power Distribution: Enables safe isolation of large motors, transformers, or capacitor banks within manufacturing plants, mines, or processing facilities, minimizing production downtime.
  • For Renewable Energy Integration: Serves as a reliable interconnection switch for solar or wind farm collection systems, allowing for safe isolation of inverter banks or transformers.
  • For Commercial Buildings & Data Centers: Offers a robust switching solution for main and backup power distribution, ensuring critical loads can be safely managed and isolated.

Backed by Jinhua Dika's established manufacturing capabilities and a commitment to international quality standards, the FLN36 Series represents a dependable choice for engineers and project managers. With an annual export value reflecting our global reach across markets from North America and Europe to Southeast Asia and Africa, our products are proven in diverse climatic and operational conditions. Our multi-port shipment flexibility ensures reliable logistics support. Choose the FLN36 Series for a combination of SF6 insulation reliability, side-operation convenience, and manufacturer-backed quality. Contact our technical sales team today to discuss your specific voltage, current, and configuration requirements, or to request detailed datasheets and project references.

Frequently Asked Questions (FAQ)

Q1: What is the primary advantage of SF6 insulation in this load break switch?
A: SF6 (Sulfur Hexafluoride) gas offers superior dielectric strength compared to air, allowing for a more compact switch design at higher voltages. It also possesses excellent arc-quenching properties, which safely extinguishes the arc generated during load breaking, protecting the contacts and ensuring reliable operation over many cycles.

Q2: Can the FLN36 switch be used for outdoor installations?
A: The standard FLN36 Series is designed and tested for indoor installation. Using it outdoors would expose it to weather conditions (rain, UV, wide temperature swings) it is not rated for, compromising safety and longevity. For outdoor applications, please inquire about our outdoor-rated switchgear solutions.

Q3: Does "side-operated" mean it can only be operated from one specific side?
A: "Side-operated" refers to the location of the operating mechanism (handle or motor) on the side panel of the switch or its enclosure. This is typically a fixed design feature for a given model. The specific side (left or right) can often be specified during the ordering process to suit your panel layout.

Q4: What is the difference between a Load Break Switch and a Circuit Breaker?
A: A Load Break Switch (LBS) is designed to make and break rated load currents under normal conditions. It provides a visible isolation gap. A Circuit Breaker is designed to interrupt fault currents (short-circuits) automatically. An LBS is often used upstream or downstream of a circuit breaker to provide a maintenance isolation point.

Q5: Is remote operation (motorization) available for this switch?
A: Yes. While the standard configuration features a manual side-operated mechanism, a motorized operating device is available as an optional accessory. This allows for remote opening and closing via control signals, facilitating integration into automated supervisory control systems.

Q6: What maintenance does the SF6 gas system require?
A: The FLN36 switch features a sealed-for-life SF6 gas system under normal operating conditions. It is designed to maintain its gas pressure and insulation properties over its specified mechanical life with no routine maintenance required. A pressure gauge or density monitor is typically provided to indicate gas condition.

Q7: What standards does the FLN36 Series comply with?
A: The switch is designed and tested in accordance with relevant International Electrotechnical Commission (IEC) standards and Chinese National (GB) standards for high-voltage alternating current switchgear. Specific standard numbers (e.g., IEC 62271-1, IEC 62271-102) are available upon request.

Q8: What is the typical delivery lead time for an order?
A: Lead times vary based on order quantity, configuration (voltage, current rating, options), and current production schedule. For standard configurations, typical lead times range from 4 to 8 weeks ex-works. Our sales team can provide a precise delivery estimate upon receipt of your detailed specifications.

Product Tags: SF6 Load Break Switch , Indoor Load Break Isolator , Side-Operated HV Switchgear