Home > Electrical & Electronics > Power Supply & Distribution > Switchgear > Indoor High Voltage 3 Phase SF6 Load Break Switch Disconnector, 12kV/24kV/36kV Rated Voltage

Indoor High Voltage 3 Phase SF6 Load Break Switch Disconnector, 12kV/24kV/36kV Rated Voltage

Indoor High Voltage 3 Phase SF6 Load Break Switch Disconnector, 12kV/24kV/36kV Rated Voltage photo-1
Indoor High Voltage 3 Phase SF6 Load Break Switch Disconnector, 12kV/24kV/36kV Rated Voltage photo-2
Indoor High Voltage 3 Phase SF6 Load Break Switch Disconnector, 12kV/24kV/36kV Rated Voltage photo-3
Indoor High Voltage 3 Phase SF6 Load Break Switch Disconnector, 12kV/24kV/36kV Rated Voltage photo-4
Indoor High Voltage 3 Phase SF6 Load Break Switch Disconnector, 12kV/24kV/36kV Rated Voltage photo-5

Product Spotlights

Indoor SF6 Load Break Switch Disconnector for 12kV-36kV systems. Features compact SF6 gas insulation for superior arc quenching and reliability in a space-saving design. Offers visible isolation for safety, flexible current ratings, and optional motorized operation. Built for long life with minimal maintenance, ideal for secure and efficient medium-voltage distribution.
US$ 450 ≥10 Units
Key Specifications
Get Latest Price
Rated Voltage:
12kV, 24kV, 36kV
Phase:
3 Phase
Type:
Indoor SF6 Load Break Switch Disconnector
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Rated Voltage 12kV, 24kV, 36kV
Phase 3 Phase
Type Indoor SF6 Load Break Switch Disconnector
Insulation Medium SF6 Gas
Application Indoor high voltage distribution systems
Configuration Fixed or withdrawable type
Operating Mechanism Manual or motorized
Standards Compliance IEC, ANSI, GB standards

As a professional manufacturer of electrical equipment, Jinhua Dika Electrical Equipment Co., Ltd. is proud to introduce our Indoor High Voltage 3 Phase SF6 Load Break Switch Disconnector. Engineered for reliability and safety in demanding power distribution environments, this product represents our commitment to providing robust solutions for the global market. With extensive experience serving diverse regions from North America to Southeast Asia, we understand the critical need for durable and high-performance switching equipment in modern electrical networks.

Our SF6 Load Break Switch Disconnector is designed to offer superior arc-quenching performance and operational safety in indoor high-voltage applications. The use of SF6 gas as an insulating and arc-quenching medium ensures a compact design with high breaking capacity and minimal maintenance requirements. This makes it an ideal choice for substations, industrial plants, and commercial facilities where space and reliability are paramount.

The core value of this switch lies in its ability to safely make and break load currents under normal circuit conditions and provide a visible isolation point for maintenance, enhancing the overall safety of the electrical system. We have developed this product to meet the rigorous demands of our international clientele, ensuring it performs consistently across various voltage ratings and operational scenarios.

Key Features and Technical Advantages:

  • Superior Arc Quenching: The SF6 gas insulation provides excellent dielectric strength and efficient arc extinction, resulting in a longer electrical life and reduced contact wear.
  • High Reliability: Sealed tank design prevents external environmental contamination, ensuring stable performance and a long service life with minimal maintenance.
  • Compact Indoor Design: Optimized for space-constrained indoor installations without compromising on performance or safety clearances.
  • Flexible Voltage Ratings: Available in 12kV, 24kV, and 36kV configurations to suit a wide range of medium-voltage distribution system requirements.
  • Safe Operation: Provides clear visible isolation, meeting safety standards for personnel protection during maintenance operations.
  • Robust Construction: Manufactured with high-quality materials and precision engineering to withstand mechanical stresses and electrical loads.

Technical Specifications Table:

Parameter Specification
Rated Voltage 12kV / 24kV / 36kV
Rated Frequency 50Hz / 60Hz
Rated Normal Current 630A, 1250A, 2000A (Customizable)
Rated Short-Time Withstand Current 20kA - 40kA (1s or 3s)
Rated Peak Withstand Current 50kA - 100kA
Insulation Medium SF6 Gas
Operating Mechanism Manual Spring or Motorized (Optional)
Mechanical Life 10,000 operations minimum
Enclosure Protection Degree IP2X or higher for indoor use

Benefits for Your Operations:

  • Enhanced System Safety: The combination of load-breaking and isolating functions in one device simplifies system design and improves operator safety during maintenance.
  • Reduced Footprint: The compact SF6 design allows for more efficient use of valuable indoor space compared to air-insulated switches.
  • Lower Lifetime Costs: Minimal maintenance requirements and high reliability translate into reduced total cost of ownership over the equipment's lifespan.
  • Operational Flexibility: Suitable for a variety of switching applications including transformer switching, feeder protection, and bus section isolation.
  • Global Compatibility: Designed to meet common international electrical standards, facilitating integration into existing and new systems worldwide.

Backed by Jinhua Dika's established manufacturing expertise and a commitment to quality systems, this Indoor SF6 Load Break Switch Disconnector is a product you can trust. Our annual export value reflects the confidence of clients across North America, South America, Europe, Asia, Africa, and Oceania. We operate from strategic ports like Shanghai, Tianjin, Guangzhou, and Ningbo to ensure efficient global logistics. Choosing our product means partnering with a manufacturer dedicated to delivering electrical solutions that combine performance, safety, and value. Contact us today to discuss how this switch can enhance the reliability and efficiency of your high-voltage distribution system.

Frequently Asked Questions (FAQ)

Q1: What is the primary advantage of using SF6 gas in this load break switch?
A: SF6 gas offers excellent dielectric strength and arc-quenching properties. This allows for a more compact switch design with higher breaking capacity and significantly reduced maintenance compared to air-insulated or oil-filled alternatives.

Q2: Is this switch suitable for both making and breaking load currents?
A: Yes, it is specifically designed as a Load Break Switch Disconnector. It can safely make and break rated load currents under normal operating conditions and also provides a visible isolation gap for safety during maintenance.

Q3: Can the operating mechanism be automated?
A: Yes. While a manual spring-operated mechanism is standard, a motorized operating mechanism is available as an optional feature for remote or automated operation, facilitating integration into smart grid or SCADA systems.

Q4: What are the typical installation requirements for this indoor switch?
A: It is designed for indoor installation in clean, dry environments such as switchgear rooms or prefabricated substations. Adequate ventilation is recommended. Specific foundation and clearance requirements are provided in the installation manual.

Q5: How does the sealed tank design benefit the user?
A: The sealed tank filled with SF6 gas prevents dust, moisture, and contaminants from affecting the contacts and insulation. This ensures long-term reliability, stable performance, and eliminates the need for regular internal cleaning.

Q6: What is the expected service life and maintenance schedule?
A: The switch is designed for a long electrical and mechanical life (typically 10,000+ operations). Maintenance is minimal and primarily involves periodic checks of the operating mechanism, gas pressure monitoring, and external cleaning. Detailed schedules are in the manual.

Q7: Are different current ratings available?
A: Absolutely. Common rated normal currents include 630A, 1250A, and 2000A. We can also provide customized ratings upon request to match your specific project requirements.

Q8: What standards is this product designed to meet?
A: The switch is designed and tested in accordance with prevalent international standards such as IEC and ANSI, as well as relevant national standards (GB). Specific standard compliance details are available upon request.

Product Tags: SF6 Load Break Switch , Indoor High Voltage Disconnector , 3 Phase Load Break Switch

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Gold Verified Supplier
1Yr
Verified Business License
Business Type
Manufacturer
Annual Export Value
US$1 Million - US$1.5 Million
Total Employees
11 - 50 People
Product Certifications
HACCP, TL900, QS9000, SA8000, ISO9001, ISO9004, ISO17799, ISO9000, ISO14000, ISO10441, ISO16949, TS16969, ISO19011:2000, OHSAS18001, Others