Home > Electrical & Electronics > Power Supply & Distribution > Switchgear > SF6 Gas Load Break Switch Disconnector for 3 Phase Indoor High Voltage Lines, 12kV to 40kV Range

SF6 Gas Load Break Switch Disconnector for 3 Phase Indoor High Voltage Lines, 12kV to 40kV Range

SF6 Gas Load Break Switch Disconnector for 3 Phase Indoor High Voltage Lines, 12kV to 40kV Range photo-1
SF6 Gas Load Break Switch Disconnector for 3 Phase Indoor High Voltage Lines, 12kV to 40kV Range photo-2
SF6 Gas Load Break Switch Disconnector for 3 Phase Indoor High Voltage Lines, 12kV to 40kV Range photo-3
SF6 Gas Load Break Switch Disconnector for 3 Phase Indoor High Voltage Lines, 12kV to 40kV Range photo-4
SF6 Gas Load Break Switch Disconnector for 3 Phase Indoor High Voltage Lines, 12kV to 40kV Range photo-5

Product Spotlights

This 3-phase indoor SF6 Gas Load Break Switch Disconnector offers reliable circuit interruption and isolation for 12kV-40kV systems. Its SF6 gas insulation ensures efficient arc quenching, long life, and compact design. Built for indoor reliability with low maintenance, it provides a safe disconnection point and operational flexibility for various high-voltage distribution applications.
US$ 450 ≥10 Units
Key Specifications
Get Latest Price
Type:
SF6 Gas Load Break Switch Disconnector
Application:
3 Phase Indoor High Voltage Lines
Voltage Range:
12kV to 40kV
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Type SF6 Gas Load Break Switch Disconnector
Application 3 Phase Indoor High Voltage Lines
Voltage Range 12kV to 40kV
Configuration 3 Phase
Operating Environment Indoor Installation
Insulation Medium SF6 Gas
Function Load Breaking and Isolation
Installation Type Fixed Mounting

As a professional manufacturer, Jinhua Dika Electrical Equipment Co., Ltd. specializes in producing high-quality electrical components for global markets. Our SF6 Gas Load Break Switch Disconnector for 3 Phase Indoor High Voltage Lines is engineered to provide reliable and safe circuit interruption and isolation within the 12kV to 40kV range. This product is designed to meet the demanding requirements of modern power distribution systems, offering superior performance, durability, and operational safety for indoor high-voltage applications.

We leverage our manufacturing expertise and commitment to quality to deliver switches that ensure stable grid operation and protect valuable equipment. With an annual export value between US$1 Million and US$1.5 Million and a dedicated team of 11-50 employees, we have established a strong presence in markets across North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, the Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, and the Domestic Market. Our products are shipped from major ports including Shanghai, Tianjin, Guangzhou, and Ningbo, ensuring efficient logistics.

Product Features & Technical Advantages:

  • SF6 Gas Insulation: Utilizes SF6 (Sulfur Hexafluoride) gas as the primary insulation and arc-quenching medium. This provides excellent dielectric strength and efficient interruption of load currents, minimizing contact wear and enhancing the switch's lifespan.
  • Robust Construction for Indoor Use: Specifically designed for indoor installation in substations, switchgear rooms, and industrial facilities. The construction withstands typical indoor environmental conditions without the need for extensive weatherproofing.
  • Wide Voltage Range Compatibility: Operates effectively across a broad spectrum from 12kV to 40kV, making it a versatile component for various stages of medium to high-voltage power distribution networks.
  • Three-Phase Operation: Designed for three-phase systems, allowing simultaneous switching of all three phases for balanced load breaking and isolation, which is crucial for system stability.
  • Clear Disconnector Function: Provides a visible and reliable isolation point in the circuit, ensuring safe maintenance, testing, and repair operations by physically separating sections of the live system.
  • Enhanced Safety: The sealed SF6 gas chamber and robust mechanical design contribute to a high level of operational safety, reducing risks associated with arc flashes and insulation failure.
  • Long Service Life & Low Maintenance: The use of SF6 gas and quality internal components results in minimal maintenance requirements and a long operational life, reducing overall lifecycle costs.

Key Technical Specifications:

Parameter Specification / Range
Product Type SF6 Gas Load Break Switch Disconnector
System Phase 3 Phase
Parameter Specification / Range
Product Type SF6 Gas Load Break Switch Disconnector
System Phase 3 Phase
Rated Voltage (Ur) 12kV to 40kV
Installation Environment Indoor
Insulation Medium SF6 Gas
Primary Function Load Breaking & Disconnecting (Isolation)
Typical Rated Current (Ir) Customizable (e.g., 400A, 630A, 1250A)
Short-Circuit Making Capacity Available upon request
Mechanical Life (Operations) High (e.g., 10,000 operations typical)

Benefits for Our Clients:

  • Operational Reliability: Ensures dependable interruption of load currents and safe isolation, contributing to the overall stability and safety of your high-voltage power system.
  • System Flexibility: The 12kV-40kV range allows deployment in various network configurations, from distribution feeders to industrial plant main connections.
  • Cost-Effective Solution: Combines the performance of SF6 technology with a design optimized for indoor use, offering a reliable solution without the cost of outdoor-rated enclosures.
  • Simplified Maintenance & Safety: The disconnector function provides a clear isolation point, making maintenance procedures safer and more straightforward for technicians.
  • Global Supply Capability: Supported by our manufacturing base and multiple shipment ports, we can provide consistent supply and timely delivery to international projects.

Trust and Quality Assurance:

Jinhua Dika Electrical Equipment Co., Ltd. operates with a strong commitment to quality and international standards. Our manufacturing processes are guided by a robust quality management framework. We serve a diverse global clientele across continents, demonstrating our product's adaptability and reliability in different market conditions. Our annual export volume reflects consistent demand and customer satisfaction. For specific certifications applicable to this product, please contact us directly, as options may be available upon request.

Choosing our SF6 Gas Load Break Switch Disconnector means selecting a component built for performance and longevity. It is designed to integrate seamlessly into your indoor high-voltage infrastructure, providing a critical function with minimal long-term hassle. We encourage you to reach out for detailed technical consultations, customized specifications, or to discuss your specific project requirements.

Frequently Asked Questions (FAQ):

  1. What is the primary advantage of using SF6 gas in this load break switch?
    SF6 gas possesses superior dielectric (insulating) and arc-quenching properties compared to air or other mediums. This allows for compact switch design, efficient interruption of higher currents, reduced contact erosion, and longer operational life, making it a preferred choice for medium-high voltage applications.
  2. Is this switch suitable for outdoor installation?
    No, this specific model is designed for indoor installation. Its construction is optimized for the controlled environment of substations, switchgear rooms, or industrial buildings. For outdoor applications, different models with appropriate weatherproofing and enclosures would be required.
  3. Can this disconnector be used for earthing (grounding) the isolated section?
    The primary function is load breaking and isolation (disconnecting). It provides a visible break in the circuit. Additional earthing (grounding) functions typically require separate earthing switches or integrated units designed for that purpose. Please inquire if combined functionality is needed.
  4. What is the typical maintenance schedule for this SF6 gas switch?
    Due to the sealed SF6 gas system and robust contacts, maintenance requirements are generally low. Routine inspections may involve checking mechanical operation, visual indicators, and gas pressure monitoring (if equipped with gauges). Major internal maintenance intervals are significantly longer than air-insulated switches.
  5. How do I select the appropriate rated current for my application?
    The rated current (Ir) is a key specification. We offer various standard ratings (e.g., 400A, 630A, 1250A) or can customize based on your system's maximum normal load current and short-time overload requirements. Providing your system details allows us to recommend the suitable rating.
  6. Are there any environmental considerations with SF6 gas?
    SF6 gas is a potent greenhouse gas if released. Our switches are designed as sealed systems to prevent leakage. Proper handling, installation, and end-of-life procedures are important. We recommend following local regulations and manufacturer guidelines for SF6 equipment.
  7. What control mechanisms are available for operating the switch?
    Operation can be manual (using a handle or lever), motorized (electric drive), or even remotely controlled depending on the model and configuration. The choice depends on your system's automation level and operational preferences.
  8. Does the switch come with mounting instructions and connection diagrams?
    Yes, comprehensive installation manuals, connection diagrams, and safety instructions are provided with the product to ensure correct and safe integration into your electrical system.
Product Tags: SF6 Gas Load Break Switch , High Voltage Disconnector , 3 Phase Indoor Load Break Switch

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Gold Verified Supplier
1Yr
Verified Business License
Business Type
Manufacturer
Annual Export Value
US$1 Million - US$1.5 Million
Total Employees
11 - 50 People
Product Certifications
HACCP, TL900, QS9000, SA8000, ISO9001, ISO9004, ISO17799, ISO9000, ISO14000, ISO10441, ISO16949, TS16969, ISO19011:2000, OHSAS18001, Others