Home > Instruments & Meters > Optical Lens & Instrument > Spectrometer > Supply of Solid - State Dye Atomic Absorption Spectrometer, Mingrui Aa2630 Type, Heavy Metal Detector for Dye Products

Supply of Solid - State Dye Atomic Absorption Spectrometer, Mingrui Aa2630 Type, Heavy Metal Detector for Dye Products

Supply of Solid - State Dye Atomic Absorption Spectrometer, Mingrui Aa2630 Type, Heavy Metal Detector for Dye Products photo-1
Supply of Solid - State Dye Atomic Absorption Spectrometer, Mingrui Aa2630 Type, Heavy Metal Detector for Dye Products photo-2
Supply of Solid - State Dye Atomic Absorption Spectrometer, Mingrui Aa2630 Type, Heavy Metal Detector for Dye Products photo-3
Supply of Solid - State Dye Atomic Absorption Spectrometer, Mingrui Aa2630 Type, Heavy Metal Detector for Dye Products photo-4
US$ 13230.77 1 Unit
US$ 11692.31 ≥2 Unit
Key Specifications
Get Latest Price
Main Markets:
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market
Location:
Nanjing, Jiangsu, China
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.

       Nanjing Mingrui Analytical Instruments Co., Ltd. AA2630 Solid Dye Atomic Absorption Spectrometer uses a PC to fully automatically control the instrument and process data. The model is equipped with a computer system platform, with data analysis and processing functions and convenient and fast data output functions. The results are accurate and reliable. It can detect a variety of trace metal elements, including more than 70 elements such as lead, chromium, cadmium, copper, iron, calcium, magnesium, zinc, chromium, mercury, arsenic, and selenium. The detection accuracy of the instrument reaches the ppb level. Phone: 18651882886 (WeChat).

Solid Dye Atomic Absorption Spectrometer main features:

       The AA2630 atomic absorption spectrometer, which perfectly combines high automation and high reliability, can meet all the requirements of modern analysis. It uses a PC to automatically control the instrument and process data. The integrated structure design of the flame atomizer and the graphite furnace atomizer allows automatic switching between the two. The eight-lamp automatic switching turret automatically adjusts the power supply and optimizes the beam position. It pre-sets the working conditions of the hollow cathode lamp for easy multi-element detection. It has automatic flow setting, automatic ignition, and automatic flameout protection. It automatically adjusts the negative high voltage and lamp current. It automatically sets the flame height and the position of the atomizer and selects the analysis conditions to ensure reliable analysis results. It automatically switches the spectral bandwidth, with five automatically selectable levels of 0.1, 0.2, 0.4, 1.0, and 2.0nm. It automatically controls the wavelength scanning, automatically searches for peaks, and quickly scans and locates the entire band. It completes automatic zero adjustment within 30 seconds, automatically sets the gas flow, and automatically selects the fuel-to-oxidant ratio for element analysis. The advanced and reliable safety protection system protects the safety of operators. The reliable position recognition system monitors the cooling water flow, flame, and abnormal pressure in real-time, which not only ensures the safety of the machine but also the safety of operators. In case of an accident, the water, electricity, and gas are automatically shut off. It can be optionally equipped with a hydride generator. The optical system has excellent quality and a suspended design. Vibration and changes in the ambient temperature do not affect the stability of the instrument. It has strong light energy and extremely high stability. The newly designed flame atomizer and the ultra-high-sensitivity graphite furnace can automatically optimize the temperature rise program through PC control throughout the whole process. The high stability of the heating power further improves the reliability of the analysis values.

       This set is equipped with the most convenient, reliable, and practical assistant software, which supports the Windows system platform. It has simple man-machine dialogue, powerful data analysis and processing functions, and convenient and fast data output functions, ensuring accurate and reliable results.

Solid Dye Atomic Absorption Spectrometer detailed description:

Optical system wavelength range: 190 - 900nm

Monochromator: Aberration-corrected C-T monochromator dispersion element

Plane diffraction grating: 1800 lines/mm

Engraved area: 40x40mm2

Spectral bandwidth: Five levels of 0.1, 0.2, 0.4, 1.0, 2.0nm are automatically selectable. The wavelength is better than ±0.20nm across the full band.

Wavelength repeatability:

Baseline drift: 0.004A/30min

Detector: High-sensitivity, wide-spectrum photomultiplier tube

Resolution: When the spectral bandwidth is 0.2nm, it can separate the manganese doublet (279.5nm and 279.8nm), and the valley-to-peak energy ratio is

Characteristic concentration of the flame atomization system: (Cu) 0.02ug/ml/1%

Detection limit (Cu): 0.005ug/ml

Burner: 100mm metal titanium burner, air-cooled pre-mixing type. Precision RSD ≤ 0.8%

Nebulizer: Glass nebulizer. The atomization chamber is made of corrosion-resistant materials. The position of the atomization chamber can be adjusted. The height and front-back position of the flame burner are automatically set. It has safety measures and multiple automatic safety protection functions.

Characteristic quantity of the graphite furnace atomization system (Cd): 0.5×10-12g

Detection limit (Cd): 1.0×10-12g

Precision: RSD ≤ 3%

Heating temperature range: Room temperature - 3000℃

Heating temperature control method: Power control method in the drying and ashing stages

In the atomization stage, the light control high-power method is used. Temperature control accuracy: Accuracy ≤ 1%

Temperature rise rate: > 2000℃

Heating condition setting: Up to 11 program ramps, stepwise heating, high-power heating. Safety protection, with argon under-pressure indication, insufficient cooling water flow, overheating, over-current alarm and automatic protection functions.

Background correction: Deuterium lamp background correction ≥ 30 times at 1A. Self-absorption background correction ≥ 30 times at 1A

Concentration calculation method of the graphite furnace method: Standard curve method (1 - 3 order curves), interpolation method

Number of repeated measurements in the standard addition method: 1 - 20 times. Calculate the average value of repeated measurements, automatically give the standard deviation and relative standard deviation results for printing.

Parameter printing: Print data results, print graphics

Summary report software environment: Windows 2000/XP

Instrument parameters: Main unit power supply: AC220V/50Hz

Power: 220VA

Weight: 100kg

Volume: 1000mm (length) × 350mm (width) × 390mm (height)

Graphite furnace power supply: AC380V/50Hz

Power: 12KVA

Weight: 45kg

Volume: 500mm (length) × 320mm (width) × 800mm (height)

Working environment temperature: 10~35℃

Working environment humidity: ≤80%

Standard configuration of the main unit: Wooden box packaging and transportation, low-noise oil-free air compressor

Installation and debugging: Special air pressure gauge head and random accessories, on-site training for users on the usage method



Product Tags: 10 heavy metals detector for dyes , Heavy metals detector for paste dyes , Heavy metals detector for liquid dyes , Variety detector for heavy metals in dyes , Spectral analyzer for harmful elements