Emerson Thermodisc Fuses G4a01125c G4a00125c | Operating Temperature 125℃, 10a, 250v
How to choose between 10A and 15A?
Emerson's Thermodisc G4A01125C and G4A00125C are high-precision thermal fuses belonging to the G4A series. Both have a rated operating temperature of 125°C and are reliable guardians for equipment overheat protection. The core difference between the two lies in the rated current and breaking capacity: G4A01125C is suitable for circuits with a current of 10A, while G4A00125C can withstand a current of 15A. When choosing, please determine the model according to the working current of your equipment to ensure a safety margin.
Detailed technical parameter comparison table
Parameter items Emerson G4A01125C Emerson G4A00125C Parameter interpretation
Rated operating temperature (Tf) 125°C (±2°C) 125°C (±2°C) The precise temperature point at which the fuse melts
Holding temperature 85°C 85°C The temperature at which it can work safely for a long time current (I) 10A 15A Key difference, determines the load capacity
Rated voltage (U) 250V AC 250V AC Suitable for circuit voltage
Certification standards UL, cUL, VDE, CQC UL, cUL, VDE, CQC International safety certification, quality assurance
Lead material/length Tinned copper wire, standard length available Tinned copper wire, standard length available
In - depth interpretation of application scenarios
G4A01125C (10A) Typical applications: More suitable for devices with relatively low power, such as power adapters, chargers, small transformers, office equipment (printers/copiers), etc.
G4A00125C (15A) Typical applications: Due to its stronger breaking capacity, it is often used in kitchen appliances (coffee makers/kettles), electric irons, motors with higher power or industrial control equipment.
Frequently Asked Questions (FAQ) in model selection
Q: Can the 15A G4A00125C directly replace the 10A G4A01125C?
A: From a safety perspective, it can. However, installation dimensions and costs need to be considered. It is recommended to replace it with the original specification. Conversely (replacing a large - current one with a small - current one) is prohibited.
Q: What is the significance of the operating temperature accuracy of ±2°C?
A: High accuracy ensures the timeliness and consistency of protection, prevents the device from operating at critical temperatures, and extends its service life.
Send Inquiry to This Supplier
You May Also Like
-
G8a01077c, G8a00077c Emerson Thermodisc Thermal FuseNegotiableMOQ: 0
-
Emerson G4a00, G4a01, E4a00, E4a01 Microtemp Thermal FusesNegotiableMOQ: 0 Piece
-
Emerson Thermodisc Thermal Fuse/temperature Fuse Microtemp Tf192cNegotiableMOQ: 0 Piece
-
Microtemp Emerson Thermal Fuse Emerson Todg8a00/a01tf 240 216 250vacNegotiableMOQ: 0 Piece
-
Emerson T-o-d Microtemp Tf240c Thermal Fuse | 240℃ Thermal FuseNegotiableMOQ: 0 Piece
-
Emerson Microtemp Thermal Protector | G7f01167c G7f51167c Thermal FuseNegotiableMOQ: 0 Piece
-
Emerson Fuses, Microtemp G7f01134c, G7f51134c Thermodisc Thermal ProtectorsNegotiableMOQ: 0 Piece
-
Microtemp Fuses G7f01128c, G7f51128c, Emerson Thermodisc, High PrecisionNegotiableMOQ: 0 Piece
-
Emerson Microtemp Fuses | Models G7f01141c, G7f51141c Ultra-small Thermal FusesNegotiableMOQ: 0 Piece
-
5a 250v Miniature Thermal Fuse Emerson G7f01158c/g7f51158cNegotiableMOQ: 0 Piece