Home > Electrical & Electronics > Power Supply & Distribution > UPS > Netion UPS Dp Series Low Frequency Online UPS 6~20 KVA

Netion UPS Dp Series Low Frequency Online UPS 6~20 KVA

Netion UPS Dp Series Low Frequency Online UPS 6~20 KVA photo-1
Netion UPS Dp Series Low Frequency Online UPS 6~20 KVA photo-2
Netion UPS Dp Series Low Frequency Online UPS 6~20 KVA photo-3
US$ 300 ≥1 Piece
Key Specifications
Get Latest Price
Type:
On-line
Classification:
Lighting/Power
Application:
Other, Power supply and protection
Payment & Shipping
Payment Methods:
Port of Shipment:
Guangzhou
Delivery Detail:
30 days
Type On-line
Classification Lighting/Power
Application Other, Power supply and protection
Phase Three Phase
Brand Other, NETION
Standby Time Long-acting Machine
Standby UPS Sine Wave Output UPS
Equipment Mode Decentralized
Protection Overvoltage
Output Capacity Medium Type
Transport Package Wooden Box
Specification 6-20kVA
Trademark NETION
Origin China
DP series low frequency online UPS 1 ~ 20 kVA


Product profile

Real online UPS, pure sine wave output, applying dual conversion pure online IGBT technology. Small size, low noise, strong and durable.


Basic Features

Real online UPS, pure sine wave output, the application of dual conversion pure online IGBT technology, small volume, low noise, durable.

LCD display panel, through the LCD selection switch, convenient to check the UPS working state: whether the battery is normal, input / output voltage value, input / output frequency value, battery voltage value, output power and other important parameters.

The input voltage is particularly wide, allowing 25% of the change can be full load work, reduce the opportunity of battery discharge, effectively extend the life.

The charging current is 1~10A adjustable, which meets the charging requirements of the long-time power supply system, especially designed for China's power grid.

Special static switch design, with zero output interruption during power grid failure, and a bypass output time of

Very strong load capacity, 125% load online work for 15 minutes, load more than 125% online work for 60 seconds to bypass, load more than 150%3 seconds to bypass output, overload phenomenon disappeared after the automatic restart operation.

Output short circuit protection to ensure that the UPS is not damaged by short circuit of external load.

Temperature control and protection, set the internal temperature, protection component life.

Has a powerful load start function, can be directly turned on in the battery state, supply output.

Input / output is completely isolated, with strong anti-interference ability, strong impact resistance, safe and reliable.

Provide a dual-machine thermal backup power supply system.

Unique sound alarm to remind the user to notice the working state of the UPS.

Built-in maintenance bypass, can achieve online maintenance.

RS232 communication interface, with optional remote monitoring function.


Technical Specifications


Model

DP1kVA

DP2kVA

DP3kVA

DP6kVA

DP10kVA

DP15kVA

DP20kVA

Capacity

0.8kW

1.6kW

2.4kW

4.8kW

8kW

12kW

16kW

Input voltage

220/230VAC±25%

Input frequency

50/60Hz±10%

Output voltage

220VAC±1%

Output frequency

50/60Hz±0.5% (battery mode, unlocked)

Voltage error

±2%

Temporal reaction

±4% (100% load)

Wave form

Sine wave THD

Overload capacity

125% load working online for 15 minutes, load over 125% online   working for 60 seconds to bypass, load over 150%3 seconds to bypass output

Wave peak ratio

3:1

Battery type

Enclosed maintenance-free lead-acid battery

DC voltage (extended time with external battery)

48VDC

96VDC

192VDC

Battery capacity of standard device

12V7AH×4

12V7AH×8

12V7AH×16

Charging current

1~10A adjustable

Efficiency

90%

Transfer time

Zero ms for mains failure  and

Protection function

Over-current, overvoltage, low voltage, short circuit, battery   overcharge, overheat protection, etc

EMC

EN62040-2:2006; EN61000-3-2:2006+A1:2009+A2:2009

Power loss alarm

1 time/4s, keep 90s

Battery low-voltage alarm

1 second/ 1 time (battery discharge to protection voltage, UPS automatically 

shutdown, automatically boot when mains recovery)

Overload alarm

Continuous calling (hold the jump bypass for 60 seconds, automatic recovery 

after load reduction)

Failure warning

Continuous beep

LED display

main input/ bypass/ inverter/ low battery/ overload/ fault

LCD display

UPS status: input/ output/ battery voltage, input/ output frequency, load amount

Communication interface

Rs-232/ dry contact, support remote monitoring and management

Running temperature

0ºC~40ºC

Running height

Elevation

Humidity

0%~90% (no condensation)

Noise

Dimension (D×W×H) mm

520×180×400

595×215×420

590×245×530(730)

685×360×825

Reference Weight (kg)

Extended time

30

41

52

48

69

130

155

Standard

41

58

69

85

110

147

172


Note: Customizable output power PF=0.9.

* The above parameters may be adjusted and changed, please refer to the physical object.



Product Tags: Low Frequency Online UPS , Industrial UPS , 192V Online UPS

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Business Type
Manufacturer
Year Established
2001
Factory Size
10,000-30,000 square meters
Annual Export Value
US$5 Million - US$10 Million