Home > Health & Medicine > Medical Equipment > Disinfect Equipment & Sterilizer > YS-227Y Bacteriophage Penetration Tester (4-Station)

YS-227Y Bacteriophage Penetration Tester (4-Station)

YS-227Y Bacteriophage Penetration Tester (4-Station) photo-1
US$ 6200.00 - 15000.00 MOQ: 1 Unit
Key Specifications
Get Latest Price
Business Type:
Manufacturer
Year Established:
2014
Annual Export Value:
Below US$1 Million
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.

Scope of Application:

Performs high-pressure penetration testing on products.

Compliant Standards:

1. ASTM F1671 Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174 Bacteriophage Penetration as a Test System,

2. YY/T 0689-2008 Test method for resistance of protective clothing materials to penetration by blood-borne pathogens using Phi-X174 bacteriophage,

3. YY/T 0700-2008 Test method for resistance of protective clothing materials to penetration by synthetic blood,

4. GB/T 19082-2009 Technical requirements for medical disposable protective clothing.

Instrument Features:

1. Uses compressed air; silent air pump.

2. Positive pressure sensor for real-time monitoring.

3. Precision pressure regulating valve for stepless adjustment (pressure hold time/configurable).

4. Adjustable spray time; automated operation.

5. Clamping device for easy sample handling.

6. Sample loading/unloading: Ratchet torque wrench (13.6N.m), convenient & torque-controlled.

7. HMI operation; touchscreen shows real-time pressure. Independent pressure display per station. Floor-standing design; controls above fixture prevent liquid short circuits

Technical Parameters:

1. 4 independent test stations. Each has a protective cover.

2. Control: Manual/button. Master pressure gauge for observation.

3. Pressure: Adjustable 20kPa/2psi (accuracy 0.1kPa).

4. Test pressure: 0-20kPa (2psi) (adjustable). Set points: 1.75kPa (±0.5 kPa), 3.5kPa (±0.5 kPa), 7kPa (±0.5 kPa), 14kPa, 20kPa (±0.5 kPa).

5. Micromanometer range: 0-0.1kPa.

6. Pressure resolution: 0.1kPa.

7. Timing accuracy: 0.1s.

8. Test medium: Synthetic blood (customer-provided).

9. Control: Manual/button.

10. Sample size: 75x75mm; Pressure area diameter: Φ57mm.

Test Procedure:

Secure sample on fixture. Spray 2ml/60ml synthetic blood (surface tension 0.042±0.002N/m) horizontally from 30.5cm distance using a 0.84mm ID needle at 16kPa/2psi pressure onto target area. Remove and visually inspect within 10s/60s.


Product Tags: blood , antibacterial , Medical protective clothing

Send Inquiry to This Supplier