Home > Electrical & Electronics > Electrical Control System > Honeywell TC-CCR014 97197975-A01 Redundant Network Interface Module

Honeywell TC-CCR014 97197975-A01 Redundant Network Interface Module

Honeywell TC-CCR014 97197975-A01 Redundant Network Interface Module photo-1
Honeywell TC-CCR014 97197975-A01 Redundant Network Interface Module photo-2
Honeywell TC-CCR014 97197975-A01 Redundant Network Interface Module photo-3
Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Material:
Other, Honeywell
Condition:
Other, Global universal model
Task:
Other, Global universal model
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
Material Other, Honeywell
Condition Other, Global universal model
Task Other, Global universal model
Mathematical Model Other, Global universal model
Signal Other, Global universal model
Customized Other, Global universal model
Structure Other, Global universal model
Operating Voltage 24V DC±10%
Dimensions 100mm (L) × 80mm (W) × 60mm (H)
Honeywell TC-CCR014

Functional Features

  • Flexible Configuration and Connection
    It can be used in conjunction with Process Managers, C200, or C300 controllers to achieve "plug-and-play" conversion, providing users with flexible control solutions. It can be located in the process field or remotely connected to the control processor, and installed on a DIN rail for convenient installation and layout according to actual needs.
  • High-Reliability Design
    The C-series I/O products integrate Honeywell's years of successful experience and innovative technologies, equipped with a unique patented thermal channel form. Its components can be implemented in a redundant manner, providing a single-point-failure-free solution to ensure stable system operation under various working conditions.
  • Easy Maintenance
    With a user-friendly experience, it ensures reduced floor space, easy installation, and simple maintenance, helping to lower maintenance costs and downtime, and improve system availability and production efficiency.

Technical ParametersI. Electrical Parameters

Parameter TypeSpecific Index
Operating VoltageTypically supports DC power supply, with a voltage range of approximately 24V DC±10%.
Power ConsumptionTypically low power consumption, generally within 5W, depending on the operating status and configuration.
Number of I/O LinksSupports 2 PMIO (Process Manager I/O) links, with each link connectable to up to 32 I/O modules, totaling 64 modules.
Communication ProtocolCompatible with the communication protocol of Honeywell C300 controllers, supporting data interaction with controllers through dedicated links (such as redundant channels).
Signal Transmission RateHigh-speed data transmission to meet the real-time requirements of industrial control.

II. Physical Parameters

Parameter TypeSpecific Index
DimensionsCompact design suitable for industrial control cabinet installation, with typical dimensions of approximately 100mm (L) × 80mm (W) × 60mm (H) (subject to the actual product).
WeightApproximately 0.5kg, lightweight and easy to install.
Installation MethodSupports DIN rail installation, which can be directly fixed in the control cabinet to save space.
Interface Types- Link interface: Used to connect I/O modules and controllers, typically a dedicated interface (such as pin-type or plug-in type).
- Address setting interface: Determines the I/O link address through a prefabricated jumper insertion design.

TC-CCR014 97197975-A01 (3)

TC-CCR014 97197975-A01 (1)

TC-CCR014 97197975-A01 (2)

III. Environmental Parameters

Parameter TypeSpecific Index
Operating Temperature Range- Standard type: -40°C to +70°C (adapting to the wide temperature environment of industrial sites).
- Some models may support a narrower range, subject to the manual.
Storage Temperature Range-40°C to +85°C, meeting long-term storage requirements.
Humidity Range5% to 95% (non-condensing), adapting to humid environments.
Protection LevelThe housing protection level is typically IP20 (indoor installation). If used in harsh environments, it needs to be combined with cabinet protection.
Vibration/Shock Resistance- Vibration resistance: Complies with industrial standards (such as IEC 61326-1), and can withstand continuous vibration (such as 5~500Hz, 10g acceleration).
- Shock resistance: Can withstand instantaneous shock (such as 50g acceleration, 11ms).

IV. Reliability Parameters

Parameter TypeSpecific Index
MTBF (Mean Time Between Failures)High-reliability design, with MTBF typically > 100,000 hours (approximately 11 years), suitable for long-term continuous operation scenarios.
Redundancy SupportSupports link redundancy and component redundancy (such as power supplies, communication channels), reducing the risk of single-point failures and improving system availability.
Diagnostic FunctionBuilt-in self-diagnosis mechanism, which can real-time monitor link status, module failures, etc., and feedback anomalies (such as fault codes) through indicator lights or communication interfaces.

Common Faults and SolutionsPower Issues

  • Fault Phenomenon: The device fails to power on or suddenly freezes during operation.

  • Possible Causes and Solutions: Check whether the power adapter works normally and whether the output voltage is within the required range of the device. Try replacing the power adapter. Check whether the power cord is firmly connected, and whether there are loose or damaged conditions. If so, reconnect or replace the power cord.

Communication Failures

  • Fault Phenomenon: The device cannot communicate with other devices, such as being unable to connect to the controller or host computer software.

  • Possible Causes and Solutions: Confirm whether the communication interface is correctly selected, check the communication parameter settings (such as baud rate, data bits, stop bits, parity bit, etc.) to ensure consistency with the settings of the connected device. Check whether the communication cable is intact and whether the interface is loose. Try re-plugging or replacing the communication cable. For network communication, check whether the device's network parameters (such as IP address, subnet mask, gateway, etc.) are correct, and try the ping command to test the network connection.

Sensor Faults

  • Fault Phenomenon: Abnormal detection data, such as large numerical fluctuations, obvious deviation from the actual value, or no data output.

  • Possible Causes and Solutions: Check whether the sensor is contaminated, blocked, or damaged. If so, clean, dredge, or replace it according to the sensor type. Confirm whether the sensor's installation position is correct and whether it is affected by external interference (such as strong electromagnetic interference, vibration, etc.). If so, adjust the installation position or take corresponding protective measures. Check whether the sensor's power supply is normal, and use a multimeter to measure the supply voltage.

Display Problems

  • Fault Phenomenon: No display on the screen, blurred display, screen flickering, or garbled characters.

  • Possible Causes and Solutions: Check whether the display connection is good. If loose, reconnect it. Clean the display surface. If damaged, replace the display. Check whether the device's display settings are correct, and try adjusting parameters such as brightness and contrast. If it is a software problem, try restarting the device or updating the device's firmware and driver.

Abnormal Control Functions

  • Fault Phenomenon: The device cannot perform control operations according to the set program or instructions, such as being unable to start, stop, or adjust parameters.

  • Possible Causes and Solutions: Check whether the control instructions are correctly sent and confirm whether the control signal transmission line is normal. Check whether the device's control logic settings are correct and whether there are conflicting or incorrect configurations. Check whether the controlled device works normally (such as whether the actuator is damaged and whether the power supply is normal). Consider whether external factors affect the control function (such as the triggering of safety protection devices and external signal interference).

Product Tags: TC-CCR014 , 97197975-A01 , 97321174-A01

Send Inquiry to This Supplier

Message
0/5000
Want the best price? Post an RFQ now!
1Yr
Business Type
Trading Company
Year Established
2014
Factory Size
1,000-3,000 square meters
Product Certifications
SA8000