Acrel AID150 Medical Digital Centralized Alarm Insulation Display Instrument Indicator Device for Hospital Operating Room
AID series alarm and display device is a remote display and sound and light alarm device by using advanced fieldbus communications technology. The device can be installed on the operating room or ICU, the medical staff can easily know the status of medical isolated power systems, and the type of fault when the system fails.
-The insulation resistance alarm value, load current alarm value and transformer temperature alarm value of the system can be set remotely. -When the system appears insulation fault, overload, transformer temperature over limit and wiring fault, alarm and display instrument gives out the corresponding sound and light alarm, and has the function of eliminating sound alarm. -Using advanced fieldbus technology, the remote monitoring function can be realized by real-time data interaction with the insulation monitor.
Parameter/Model |
AID10 |
AID120 |
AID150 |
AID200 |
|
Auxiliary power |
Voltage |
DC 24V |
|||
Power consumption |
<0.6W |
||||
Insulation resistance measurement range |
0-999kΩ |
/ |
|||
Insulation alarm value range |
50-999kΩ |
/ |
|||
Transformer load rate display |
Percentage display |
/ |
|||
Load current alarm settings |
14A、18A、22A、28A、35A、45A |
||||
Temperature alarm value range |
0~+200℃ |
||||
Alarm |
Sound and light alarm |
||||
Alarm type |
Insulation fault, overload, over-temperature, equipment failure |
||||
Communication |
RS485 interface, MODBUS-RTU protocol |
CAN interface, a custom protocol |
|||
Display method |
LED display |
128*32 LCD |
|||
Send Inquiry to This Supplier
You May Also Like
-
Acrel Insulation Fault Locator AIL150-8 Using CAN Bus Technology, Insulation Faults of 8 Circuits Can be LocatedNegotiableMOQ: 1 Piece
-
Acrel AIL160-6 Can Locate 6 Loops and Exchange Data With Other Devices Fault Location EvaluatorNegotiableMOQ: 1 Piece
-
Acrel Insulation Monitoring Device Multiple Fault Indication Function Mainly Used in IT Power Distribution Systems AIM-T300NegotiableMOQ: 1 Piece
-
Acrel Using CAN Bus Technology, Insulation Faults of 8 Circuits Can be Located Insulation Fault Locator AIL150-8NegotiableMOQ: 1 Piece
-
Acrel Accurately Locate the Circuit AIL150-4 Insulation Fault Locator Where the Insulation Fault is LocatedNegotiableMOQ: 1 Piece
-
Acrel for Hospital Operating Room AID150 Medical Digital Centralized Alarm Insulation Display Instrument Indicator DeviceNegotiableMOQ: 1 Piece
-
Acrel Using CAN Bus Technology, Insulation Faults of 8 Circuits Can be Located Insulation Fault Locator AIL150-8NegotiableMOQ: 1 Piece
-
Acrel Insulation Fault Locator Accurately Locate the Circuit Where the Insulation Fault is Located AIL150-4NegotiableMOQ: 1 Piece
-
Acrel Hospital Isolation Monitoring Device Medical IT Power Supply Hospital Insulation Power Supply Hospital Isolated PowerNegotiableMOQ: 1
-
Medical IT System Insulation Fault Locator AIL100-8NegotiableMOQ: 1