Universal Dry Dispersion Winner 3003 Laser Particle Size Analyzer, Adopt MIE Scattering Principle
Product Description
Winner3003 is a universal dry dispersion laser particle size analyzer, adopt MIE scattering principle, using the scientificstructure design and a new generation of dispersion device, the dispersion effect is better than similar instruments. Using MIE scattering theory as the theoretical basis, converging Fourier transform optical path, and with high stability and He-Ne laser high-sensitivity photodetectors ring ensures repeatability and accuracy of test results.
This product use air as the dispersing medium, the use of turbulent dispersion principle, with high-precision feeding apparatus and Patent powder injection pumps, No-Oil silent air source, ensure that the sample is thoroughly dispersed. It is applied to any powder material, particularly good for materials occurs chemical reaction in water, or shape change in the liquid. It have same accuracy and repeatability compared with the wet method.
Main Features
(1)Unique patent technology of optical path and detection system, greatly improve testing resolution.
Converging Fourier transform optical path patent technology overcome lens aperture restriction on the scattering angle, expand testing range in limited space, and add more secondary integrated photodetectors, which can effectively collect scattered light from all angles in the the corresponding test range, make sure the testing accuracy and reliability within the full range.
(2)Scientific and automatic dry dispersing system
Turbulence dispersion patented technology and Normal shock shearing effect make particles sufficient dispersion, dispersion core part using wearable ceramics not only improve dispersion system’s working life but ensure more accurate and stable testing result.
(3) Intelligent Operation System realize one key test
(4) Software support
Unique unconstrained free fitting technology make particle analysis not be restricted by any functions, truly reflect particles distribution, ensure accuracy of testing result.
Specification
Application
Winner3003 Dry laser particle size analyzer used in cement, ceramics, pharmaceuticals, dyes, pigments, fillers, chemical products,catalysts, coal dust, additives, pesticides, explosives, graphite, photographic materials, fuel, metal and non-metal powder,carbonated calcium, kaolin and other powder industry, particularly for materials which occurs chemical reaction, the shape change and the loss in the liquid, such as herbs, magnetic materials and relatively wide distribution and larger particles powders, have more unique applicability and practicality.
Quality Assurance
1. Strictly conforming to ISO9001-2000 quality management system.
4.Only qualified components will be assembled and total laser particle size analyzer must be inspected completely before sale.
5.Laser particle size analyzer will be processed preventing -shake test before delivery.
After Sale Service
1.Operation demo video CD will be offered.
5. We offer the components with favorable price and perdurable maintenance.
FAQ
Purchase laser particle size analyzer need know points:
(1) What materials need test?
If suspension/emulsion, must choose liquid dispersion particle size analyzer, and some materials are also reacted with water, so need liquid dispersion particle size analyzer also. Generally, cement, metal powders and pharamcy materials need dry dispersion model particle size analzyer.
By now, Based on MIE scattering, laser particle size analyzer can test the particle range is 0.01um-2000um.
If materials range is not so wide, for example, 10um-20um, smaller range of particle size distributon choose closer range model will be preciser, no need to buy large range model.
For liquid model, in order that sample can disperse well and circualte in the laser particle size analyzer, generally we need use water, alochol or organic solvent as dispersion media.For dry dispersion model, just use compressed air as dispersion media.In the current market, Dry laser particle size analyzer cost is higher than liquid dispersion models, so if can test well, liquid model is better.
Send Inquiry to This Supplier
You May Also Like
-
Winner 3009B Dry Intelligent Laser Particle Size Analyzer Adopts Spectrum Amplification TechnologyUS$ 9998 - 21998MOQ: 1 Set
-
Winner 319 1um-500um Small Spray Equipment Medical Nebulizers Used Spray Laser Particle Size AnalyzerUS$ 12998 - 21998MOQ: 1 Set
-
Winner 311xp Small Benchtop Portable Droplet Test Spray Laser Particle Size Distribution Analyzer Standard is ISO13320:2009US$ 9598 - 14598MOQ: 1 Set
-
Winner 802/803Photon Correlation DLS Nano Particle Size AnalyzerUS$ 1998 - 27998MOQ: 1 Set
-
Winner 99E High Resolution Particle Shape Image AnalyzerUS$ 1998 - 6999MOQ: 1 Set
-
Winner 901 Photon Correlation DLS Nanoparticle Size and Zeta Potential AnalyzerUS$ 44998 - 49998MOQ: 1 Set
-
The Test Criteria Arewinner 2000ZDE Wet He-Ne Laser Particle Size Analyzer of ISO13320-1:1999US$ 12998 - 16998MOQ: 1 Set
-
Winner 2005 Solid Powder Testing Automatic Laser Particle Size Analyzer for Particle Size TestingUS$ 8998 - 18998MOQ: 1 Set
-
Winner 2006 Laboratory Wet Test Method Automatic Powder Laser Particle Size AnalyzerUS$ 11988 - 18988MOQ: 1 Set
-