Home > Electrical & Electronics > Electronics Stocks > Winner 2008A Laser Particle Size Distribution Analyzer for Pesticides Measurement

Winner 2008A Laser Particle Size Distribution Analyzer for Pesticides Measurement

Winner 2008A Laser Particle Size Distribution Analyzer for Pesticides Measurement photo-1
Winner 2008A Laser Particle Size Distribution Analyzer for Pesticides Measurement photo-2
Winner 2008A Laser Particle Size Distribution Analyzer for Pesticides Measurement photo-3
Winner 2008A Laser Particle Size Distribution Analyzer for Pesticides Measurement photo-4
Winner 2008A Laser Particle Size Distribution Analyzer for Pesticides Measurement photo-5
US$ 1998 - 28578 MOQ: 1 Set
Key Specifications
Get Latest Price
Brand Name:
Winner
Place of Origin:
China
Model Number:
Winner2008A
Payment & Shipping
Payment Methods:
Port of Shipment:
Qingdao/kangkong
Delivery Detail:
Delivery time depends on order quantity.
Brand Name Winner
Place of Origin China
Model Number Winner2008A

Product Description

Winner2008A full automatic wet laser particle size analyzer adopt MIE scattering principle, measure size is from 0.01μm to 2000μm, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field.


Main Features


(1)Winner Patent -Optical path design
Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Double spectrum design make its precision achieves from 0.01um to 1200μm,and Dual-laser orthogonal light make use of the semiconductor auxiliary laser extend the test angle from 45 degree to 135 degree, ensure receive all the angles of signals.

(2) Expand Size Range
measurement range significantly expanded to 0.01um, particularly suitable for small samples of the user, the sub micron particle test results reached the international level

(3)Full built-in dispersion system
The ultrasonic dispersion, mechanical stirring and circulation channel reasonable integrated in the interior of the instruments, ensure the uniform dispersion and distribution of particles in the testing process, effectively avoid uneven distribution, large particle deposition phenomenon caused by long pipe line of outside dispersion system , to ensure the accuracy of the test results.

(4)Intelligent Operation mode
With intelligent automatic mode of operation, to achieve a key test, as long as according to the prompt addition of sample, click the "test", all processes including water-supply, dispersion, circulation, testing, cleaning, data record, data analysis, save and print are automatically completed, not only reduce the testing workload, but also eliminate the interference of human factors, to further improve the accuracy and authenticity of testing results.

(5)Automatic Optical path alignment system

The precision of four hybrid stepping motor in the automatic system of optical components, micro precision of 0.1um, the instrument of light path is always at its best to eliminate manually on the light path and the troubles and difficulties but also enhance the accuracy and stability of test results.


(6)Authoritative calibration method
In the entire test range using the national standard materials for calibration, only a year calibration once the instrument can. Calibration method is simple and quick.

(7) Unconstrained free fitting technique

Winner original unconstrained free fitting technology, particle size analysis is not affected by any functional constraints, can be a true reflection of the distribution of particles.


Specification

Model Name
Winner2008A

Standard
ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009
Principle
MIE scattering principle
Measuring Range
0.01μm-2000μm

Channels Number
127

Accuracy error
≤0.5% (Deviation of D50 on national standard sample)
Repeatability error
≤0.5% (Deviation of D50 on national standard sample )
Light source
High performance He-Ne Laser (λ= 632.8nm, P>2MW)
Lifetime>25000hours

Dispersion
Method
Ultrasonic
Frequency:40KHz Power:35W, Time: ≥1S ,Anti-dry function
Stir
Revolutions Speed: 0-3000RPM (Adjustable)
Circulate
Rated Flow:8L/min Rated Power:10W
Sample Pool
Volume:350mL
Micro-
Sample Pool
Volume: 10mL ( Available)
Operation Mode
Full automatic/ manual control, freely choose
Resolution
Free distribution truly reflect particle size distribution
Optical bench alignment system
Japan Canon lens, Full automatic,precision is up to 0.1um
Software function
Analysis mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
Statistic Method
Volume Distribution, Quantity Distribution
Statistic Comparison
Several Testing Results of samples
Different batches of samples testing result,
Samples before and after processing,
Test result of samples in different time.
User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries
Test Report
Word, Excel,Photo( Bmp), Text etc
Multiple-language Support
Multiple language Support
Intelligent operation
Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor
Testing speed
Outer dimension
L104cm*W44cm*H54cm
Net weight
58Kg

Application

Winner2008 is widely used in mineral materials, cement, ceramics, chemicals, paint, emulsion, dyes, pigments, fillers, chemical products, catalysts, drilling mud, abrasive, lubricant, coal, sand, dust, bacteria, cells, food, additives, pesticides, explosives, graphite, photosensitive materials, fuel, and ink metal and non metal powder, calcium carbonate, kaolin, coal water slurry and other powder material.


Company Profile

Jinan Winner Particle Instrument Co., Ltd. have  have been specialized in particle size analyzer for more than 30 years, since we undertake National Science Project-particle size analyzer development  in 1985. We are the 1st manufacturer to produce Nano-particle size analyzer in China. Our particle size analyzer will enable you understand materials well, and save your time and cost.  Reliable data enables scientists, researchers and engineers to evolve formulations and processes with confidence. Our products guide research and product development, manage and control manufacturing quality, and optimize output. By now, We have Laser Particle size analyzer, Image particle size analyzer, Spray particle size analyzer, particles counter and Nano-particles size analyzer and so on. We are dedicated to offer you the best particle size analysis solution. Your satisfaction is our eternal target!




Quality Assurance

1. Strictly conforming to ISO9001-2000 quality management system.

2. Strict control from purchasing materials, process inspection to final particle size distribution test.
3. QC department to execute quality control regulations.
4.Only qualified components will be assembled and total laser particle size analyzer must be inspected     completely before sale.

5.Laser particle size analyzer will be processed preventing -shake test before delivery.


After sale service


1. Provide operation demonstration video.

2. Provide free installation and training services.

3. The warranty period is 1 year after receipt of the goods, and technical support is provided for life.

4. If repair parts are provided, we will provide parts at favorable prices, only charge cost prices, and provide long-term maintenance.



Product Tags: particle size analyzer , laser diffraction particle size analyzer , particle size analyzer price , mastersizer , particle size analyser , particle analyser

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Business Type
Manufacturer
Year Established
1985
Factory Size
Below 1,000 square meters
Annual Export Value