Home > Industrial Equipment & Components > Environment Protection Device > Waste Treatment Equipment > IACS Approved 700m3/h UV Ship Ballast Water Treatment System BWS

IACS Approved 700m3/h UV Ship Ballast Water Treatment System BWS

IACS Approved 700m3/h UV Ship Ballast Water Treatment System BWS photo-1
IACS Approved 700m3/h UV Ship Ballast Water Treatment System BWS photo-2
IACS Approved 700m3/h UV Ship Ballast Water Treatment System BWS photo-3
IACS Approved 700m3/h UV Ship Ballast Water Treatment System BWS photo-4
IACS Approved 700m3/h UV Ship Ballast Water Treatment System BWS photo-5
US$ 50000 - 90000 MOQ: 1 Set
Key Specifications
Get Latest Price
Brand Name:
GOHI
Place of Origin:
China
Model Number:
LS700
Payment & Shipping
Payment Methods:
Port of Shipment:
Shanghai
Delivery Detail:
15 days
Brand Name GOHI
Place of Origin China
Model Number LS700

Product Introduction

700m3/h UV Ship Ballast Water Treatment System BWS uses advanced full-automatically backwash filter, with high-efficient medium-pressure UV radiation technology to accomplish the online treatment of ship ballast water. LS BWMS has been type approved in accordance with MEPC.300(72) aka new G8 and BWMS Code by China Classification Society (CCS) and fully meet “D-2” discharge standard.

700m3/h UV Ship Ballast Water Treatment System BWS offers simple operation and simple maintenance, dual-directional (local and remote) automatic control, friendly interface, and easy manipulation. The system is in unit-modular design with a capacity range from 150~3000m³/h, thus providing flexible and simple installation on small tonnage vessels while multiple units assembled installation on large-tonnage vessels. Therefore, it takes no large space. Meanwhile, the system is also suitable for old ships with narrow space.

The filtration plus UV radiation method takes no additional contamination with no adding or reserving chemicals. The entire system is completely closed in operation thus causing no hazards of radiation or noise to the crew.

System control can be realized through the optional remote control box for local and remote two-way control. Meet on-site and remote operation. The whole process is convenient, intuitive and reliable. The system working data can be stored and recorded to reflect the operation of the equipment during the ship's voyage, and can provide working operation records according to the requirements of the inspection department, with long-term traceability.


Working Principle

The System includes Filter, UV Reactor, Control Unit, Power Cabinet, and Electric Valves, monitoring equipment, sampling device and pipeline. General working modes include ballasting and de-ballasting processes, as well as ballast stripping and emergency bypass.

Technical Specification

Model LS-700
Capacity ( m3/h): 5000
Filter × Qty: LSF-700 ×1
UV Reactor × Qty: LSV-700 × 1
Control Unit × Qty: LSC-1L × 1
Power Cabinet × Qty: LSP-1 × 1
Rated Power (kW)*: ~18

Power Consumption


Component

Power Consumption (kW)

Continuous loads

Intermittent loads

Power cabinet 13 0.5
 Control Unit 1.0 0.5
Backflush pump / 3
 sub-total 14 4
 Total 18


Working Conditions

Working Conditions

Humidity

095

(Equipment in Engine Room)

Ambient temperature

055

Seawater temperature

035

Slope & Swing

Static

 All directions ≤22.5°

Dynamic

 All directions ≤22.5°

Electromagnetic

Compatibility

Voltage floating

±10%

Instantaneous voltage floating

±20%

Frequency floating

±5%

Instantaneous frequency floating

±10%

(Recover in 3 seconds)

Power Supply

380(440)V, 50(60)Hz, 3Φ

Fresh Water

About 2.0 m3 / time

For replacing seawater in BWMS when storage

General Requirement of Relevant Piping

Shipbuilding standard are mandatory regarding relevant piping, sampling facilities and pipes used along for firefighting, and shall be easy to clean, inspect, service and operate. The freshwater piping shall not be mixed up with seawater and piping design pressure shall not exceed 1.0MPa.

Electrical

Requirements

The cable connected to the system shall be approved marine cable.


Main Model List


Model Rated Capacity (m3/h) Capacity Range (m3/h) Power (KW) Weight (Ton) Length (mm) Width (mm) Height (mm)
BWS-150 150 50-150 22 1.5 2600 1000 1700
BWS-250 250 150-250 26 2.2 2400 2100 1800
BWS-350 350 250-350 35 2.3 2400 2100 1900
BWS-500 500 350-500 50 2.4 2400 2100 2000
BWS-850 850 500-850 74 3.0 3100 2400 2300
BWS-1150 1150 850-1150 98 3.3 3500 2500 2300
BWS-1500 1500 1150-1500 123 4.1 4500 3000 2400
BWS-1700 1700 1500-1700 146 5.9 5000 3100 2300
BWS-2300 2300 1700-2300 194 6.5 5500 3800 2300
BWS-3000 3000 2300-3000 243 8.2 6500 4500 2400


Automatic Backflush Filter as the first step of the system is specifically designed for ballast water screening, which has fine mesh elements aiming to remove the microbe and sediments with size larger than 50μm.

Filter adopts the up-to-date concept of auto backflush to efficiently fulfill filtering and screen-cleaning at the same time, backflush automatically starts based on differential pressure while filtration continues, with no other manual on-site operations needed.

Filter functions only in Ballasting process while it is bypassed in De-ballasting process and By-pass process.


Product Tags: ship ballast water treatment system , 700m3/h ballast water system , BWS

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Business Type
Trading Company
Year Established
2021
Annual Export Value
US$1 Million - US$1.5 Million
Product Certifications
ISO9001

Recommended Categories

Explore top categories and find suppliers for your specific needs