Standards
ASTM E1530-06
GB/T29313-201
ASTM C518-04
GB10295-2008
Introduction
This instrument adopts the internationally popular heat flow meter testing method of thermal conductivity, equipped with a computer to realize automatic testing. It is re-optimized and designed on the basis of our company's original DRPL-1, and adapts to the testing requirements of various common materials thermal conductivity.
This instrument is based on the test principle of the steady-state flat plate method. A stable hot surface temperature is added to the hot surface. The heat is transferred to the cold surface through the sample. The transferred heat flow is measured. Then the thermal conductivity and heat transfer coefficient can be calculated according to the thickness and heat transfer area of the sample. Hinder. This test method is simple, fast and reproducible. It is very suitable for the research and development of material heat transfer. It can be used for testing of plastics, rubber, graphite, thermal insulation materials, etc. It is widely used in colleges, universities, scientific research institutes, quality inspection, factories and mines.
Specifications
No. | Model | DRPL-2 | DRPL-2A | DRPL-2B | DRPL-2C | |
1 | Thermal conductivity range | Plate sample 0.001-5W/mk; cylindrical sample 3-500W/mk | 5-1000W/mk | |||
2 | Test accuracy | <±5% | <±4% | <±4% | <±5% | |
3 | Hot plate temperature control | RT-99.99℃ | RT-150.00℃ RT-300.00℃ | RT-150.00℃ RT-300.00℃ | RT-150.00℃ RT-300.00℃ | |
4 | Cold noodle temperature | Forced air cooling | Forced air cooling | Constant temperature bath 5--90℃ | Constant temperature bath 5--90℃ | |
5 | Test surface size | 150*150mm | φ60 (or φ80) mm | (Optional according to temperature) | (Optional according to temperature) | |
6 | Experiment time | About 3 hours | About 3 hours | φ60 (or φ80) mm | The clamping sample width is 60mm | |
7 | Heat protection device | without | Have | About 1.5 hours | About 1.5 hours | |
8 | Heat flow range | 0.5-2000W/m2, split rate 0.25 W/m2. | ||||
9 | control system | Computer automatic test | ||||
10 | power supply | 220V; 50Hz; power less than 1KW (not including constant temperature bath) | ||||
11 | Heat flow meter | Using WPY heat flow meter, the heat flow parameter is 23.26w/m2*mV. | ||||
12 | other | The plexiglass windshield is used to directly observe the experimental process. | ||||
13 | Configuration | Including one DRPL-2 test host, one set of software, one plexiglass windshield | Includes one DRPL-2A test host, one set of software, and one plexiglass windshield | Including one DRPL-2B test host, one set of software, one plexiglass windshield, one high-precision constant temperature sink | Including one DRPL-2C test host, one software, one plexiglass windshield, one high-precision constant temperature sink, one set of sample loading fixtures | |
About us
Our product
Send Inquiry to This Supplier
You May Also Like
-
Tap Density Tester Powder Density MeterUS$ 1500 - 3000MOQ: 1 Set
-
Pellet Durability Index (PDI) Tester ISO 17831-1US$ 1500 - 2000MOQ: 1 Set
-
Optical Table Air Cushion TypeUS$ 1000 - 2000MOQ: 1 Piece
-
Light Precision Optical TableUS$ 1000 - 2000MOQ: 1 Piece
-
Air Cushion Optical TableUS$ 1000 - 2000MOQ: 1 Piece
-
Infrared Oil Content AnalyzerUS$ 500 - 1000MOQ: 1 Set
-
Manual Hydraulic Pellet PressUS$ 500 - 1000MOQ: 1 Set
-
Low Temperature LCD Display Differential Scanning Calorimeter DSC Equipment ISO 11357US$ 5000 - 8000MOQ: 1 Piece
-
LCD Display Differential Scanning Calorimeter DSC Equipment ISO 11357US$ 5000 - 8000MOQ: 1 Piece
-
LCD Display Differential Scanning Calorimeter DSC Equipment ISO 11357 800℃US$ 5000 - 8000MOQ: 1 Piece