Brand Name: | Acrel | Place of Origin: | China | Model Number: | ADW |
Phase: | Three Phase | Output Voltage: | 380V | Operating Temperature: | -20℃~+55℃ |
Dimensions: | 88*54mm | Display Type: | Analog Only | Accuracy Class: | Class 1 |
Measuring Energy Range: | 0-99999KWH |
Product Description
ADW400 power monitoring module is mainly used to measure three-phase active power of low-voltage network. At the same time, it can select the current input of the largest four loops. It has RS485 communication and 470MHz wireless communication functions, which is convenient for users to monitor, collect and manage electricity. It can be flexibly installed in the distribution box to realize the measurement, statistics and analysis of individual electric energy in different regions and loads.
Naming rules for ADW400 main module
Naming rules for mutual inductor
Model and specification
Electrical performance
Electrical performance
Working environment conditions
Outline dimensions and installation instructions
Installing description
Installation mode of puncture clip
Installation notes:
1.During the installation of puncture clip, it should be avoided to break it by force;
2.After the installation of the puncture clamp, let the equipment side run full load for more than 1 hour, and measure the temperature of the cable at the installation point, which should not exceed 80℃.
wiring explain
The terminal is shown in the following figure,the current signal lines of A,B and C transformers are respective connected to IA(input),IA*(output);IB(input),IB*(output)and IC(input),IB(output);A, B and C three-phase voltage signal lines are respective connected to UA, UB and UC terminals ;N is connected to UN terminals.
Operation and Display
There are eight LED lights on the front of the front of the casing.They are:“DI1”,“DI2”,“DI3”,“DI4”,“UA”,“UB”,“UC”,“COM”.
When external switching input is available,“DI1”,“DI2”,“DI3”,“DI4”four lights on
When there is an external voltage input,“UA”,“UB”,“UC”three lights on.
COM has indicator flashing, when the red light flickers, indicating that the instrument carries out "LORA" communication, when the green light flickers, indicating that the instrument carries out RS485 communication.
Communication protocol
The instrument adopts MODBUS-RTU protocol or DL/645 protocol. For specific protocol formats, please refer to the relevant protocol standards.
Troubleshooting of Common Faults
The instrument does not turn on after installation, or a voltage indicator does not turn on.
Instrument wireless communication failure
Please connect the instrument RS485 interface with USB to 485 serial port first, read the parameters in the table through communication, confirm whether the parameters in the table are the same as the wireless configuration of the upper main station (channel and spread spectrum factor). If different, please modify the wireless parameters of the instrument to be consistent with the main station before re-testing; if the same, it may be the instrument and the main station phase. If the distance is too far or the interference is serious, we can try to use the external sucker antenna, or consider adding a new wireless main station nearby, and then test it.
Common errors check and solve
1 The meter do not light after powered, or one path of voltage indicator do not light.
Suggestion: Please turn the screw to ensure that the meter needle has been punctured and contacted with the cable inner
conductor cable.
2 Meter’s wireless communication failure
Suggestion: Please connect RS485 interface on the meter and USB convert to 485 serial port to read the parameters, and
confirm whether the parameters are the same as the upper terminal wireless configuration (channel and spread spectrum
factor). If different, please modify the meter’s wireless parameters and retest the master terminal after the same, and if
the same, it may be the meter and master terminal are in a relative long distance. It is too far to communicate or the scene
is seriously disturbed. We can try to use the external antenna at the same time, or consider the newly added wireless
master terminals, and then test it.
Company Profile
Acrel Co., Ltd.[stock code: 300286.sz] is a high-tech enterprise integrates R&D, production, sales and service, since its establishment, it committed to provide users with energy efficiency management and power security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors. At present, more than 8,000 sets of various solutions are running all over the country, help users to realize the visual management of energy consumption, provide users the energy data services, and escort users an efficient and safe energy consumption.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
Contact Us
- Jiangsu Acrel Electrical Manufacturing CO.,LTD
- Contact nameTim
- Phone86-1870-6168051
- AddressJiangyin Wuxi,Jiangsu
- Acrel ADW400 wireless multi loop energy meter
- Acrel ADW400 multi channel energy meter
- Acrel ADW400 LoRa wireless power meter
- Acrel ADW300 Wireless Metering Instrument
- Acrel ADW300 three phase energy meter
- Acrel ADW300 three phase power meter
- Acrel ADW300 DIN rail power meter
- Acrel ADW300 DIN rail harmonic energy meter
- Acrel ADW300 DIN rail max demand energy meter
- Acrel ADW300 DIN rail energy meter with 100A CT
- Acrel ADW300 DIN rail harmonic power meter
- Acrel AMB power meter for data center
- Acrel AMB Smart Alternating-current Bus Bar Monitor/Busduct energy meter
- Single phase digital kwh meters power energy meter 50HZ supporting infrared communication DDSD1352
- Acrel CE standard 2 pole width mini din rail kwh meters DDSD1352
- 10(60)A 220V 50HZ Single phase Din rail KWH watt hour din-rail energy meters DDSD1352
- Acrel DDSD1352-C 2P din rail mounted multi-function single phase energy meters with LCD display
- Manufacturing 2P single phase Din rail electric power smart meters DDSD1352
- Acrel approved DDSD1352 single phase Din rail energy meters
- Acrel 2P Kwh meters direct connect 10(60)A DDSD1352
- Acrel energy meters used in management systems DDSD1352
- Din rail mount three phase energy meters for EV charger station measurement Acrel DTSD1352
- Acrel DTSD1352 1-6A three phase energy meters
- Acrel three phase LCD display electric energy meter DTSD1352
Find Similar Products By Category
- Measurement & Analysis Instruments > Electrical Instruments > Energy Meters
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Tim
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-