Home > Electrical & Electronics > Sensor > Pressure Sensor > COH-A1 Carbon Monoxide/ Hydrogen Sulfide Sensor (CO/H2S Sensor)

COH-A1 Carbon Monoxide/ Hydrogen Sulfide Sensor (CO/H2S Sensor)

COH-A1 Carbon Monoxide/ Hydrogen Sulfide Sensor (CO/H2S Sensor) photo-1
US$ 60 - 150 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
Alphasense
Place of Origin:
United Kingdom
Model Number:
COH-A1
Payment & Shipping
Payment Methods:
Port of Shipment:
HK
Delivery Detail:
7 days
Brand Name Alphasense
Place of Origin United Kingdom
Model Number COH-A1
Usage Gas Sensor
Theory Other, Electrochemical Gas Sensor
Output Analog Sensor

COH-A1 Carbon Monoxide + Hydrogen Sulfide Sensor Introduction
Personal gas safety monitors can be found in almost every industry, with the requirement for multiple gas detection becoming commonplace. Most of these gas detectors measure both Carbon Monoxide and Hydrogen Sulfide.

Alphasense new 2sense H2S+CO gas sensor allows designers to reduce significantly their gas detector size and cost. The patented 2sense uses a new approach to dual gas sensor design.

A larger version of the D2 sensor, which has a proven track record in the field over many years, the 2sense does not compromise performance or long term stability over the standard two-sensor solution when measuring both H2S and CO.


Carbon Monoxide Sensor (CO Sensor) Specification

Carbon Monoxide Sensor (CO Sensor) PERFORMANCE
Sensitivity
nA/ppm in 400ppm CO
60 to 110
Response time
t90 (s) from zero to 400ppm CO
Zero current
ppm equivalent in zero air
Resolution
rms noise (ppm equivalent)
Range
ppm CO limit of performance warranty
2,000
Linearity
ppm error at full scale, linear at zero and 400 ppm CO
10 to 40
Overgas limit
maximum CO for stable response to gas pulse
5,000



Carbon Monoxide Sensor (CO Sensor) LIFETIME
Zero drift
ppm equivalent change/year in lab air
Sensitivity drift
% change/year in lab air, monthly test
Operating life
months until 80% original signal (24 month warranted)
24



Carbon Monoxide Sensor (CO Sensor) ENVIRONMENTAL
Sensitivity @ -20°C
% (output @ -20°C/output @ 20°C) @ 100ppm CO
45 to 75
Sensitivity @ 50°C
% (output @ 50°C/output @ 20°C) @ 100ppm CO
102 to 125
Zero @ -20°C
ppm equivalent change from 20°C
0 to 2
Zero @ 50°C
ppm equivalent change from 20°C
0 to -6



Carbon Monoxide Sensor CROSS SENSITIVITY
Filter Capacity
ppm-hours of Hydrogen Sulfide
nd
H2S   sensitivity
% measured gas @ 20ppm H2S
NO2   sensitivity
% measured gas @ 10ppm NO2
Cl2     sensitivity
% measured gas @ 10ppm Cl2
NO     sensitivity
% measured gas @ 50ppm NO
SO2   sensitivity
% measured gas @ 20ppm SO2
H2     sensitivity
% measured gas @ 400ppm H2 @ 20°C
C2H4 sensitivity
% measured gas @ 400ppm C2H4
 
NH3   sensitivity
% measured gas @ 20ppm NH3



Carbon Monoxide Sensor (CO Sensor) KEY SPECIFICATIONS
Temperature range
°C
-30 to 50
Pressure range
kPa
80 to 120
Humidity range
%rh continuous (see note below)
15 to 90
Storage period
months @ 3 to 20°C (stored in sealed pot)
6
Load resistor
Ω (recommended)
10 to 47
Weight
g


Hydrogen Sulfide Sensor (H2S Sensor) Specification


Hydrogen Sulfide Sensor (H2S Sensor) PERFORMANCE
Sensitivity
nA/ppm in 20ppm H2S
700 to 1000
Response time
t90 (s) from zero to 20ppm H2S @ 20°C
Zero current
ppm equivalent in zero air
0 to -0.3
Resolution
rms noise (ppm equivalent)
Range
ppm H2S limit of performance warranty
200
Linearity
ppm error at full scale, linear at zero and 20ppm H2S
0 to -3
Overgas limit
maximum ppm H 2 S for stable response to gas pulse
500



Hydrogen Sulfide Sensor (H2S Sensor) LIFETIME
Zero drift
ppm equivalent change/year in lab air
Sensitivity drift
% change/year in lab air, monthly test
Operating life
months until 80% original signal ( 24 month warranted)
24



Hydrogen Sulfide Sensor (H2S Sensor) ENVIRONMENTAL
Sensitivity @ -20°C
% (output @ -20°C/output @ 20°C) @ 20ppm H2S
80 to 90
Sensitivity @ 50°C
% (output @ 50°C/output @ 20°C) @ 20ppm H2S
105 to 115
Zero @ -20°C
ppm equivalent change from 20°C
Zero @ 50°C
ppm equivalent change from 20°C



Hydrogen Sulfide Sensor (H2S Sensor) CROSS SENSITIVITY
NO2   sensitivity
% measured gas @ 10ppm NO2
Cl2     sensitivity
% measured gas @ 10ppm Cl2
NO     sensitivity
% measured gas @ 50ppm NO
SO2   sensitivity
% measured gas @ 20ppm SO2
CO     sensitivity
% measured gas @ 400ppm CO
H2     sensitivity
% measured gas @ 400ppm H2
C2H4 sensitivity
% measured gas @ 400ppm C2H4
NH3   sensitivity
% measured gas @ 20ppm NH3


Product Tags: CO/H2S Sensor , Electrochemical Gas Sensors

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Distributor/Wholesaler
Year Established
2014
Overseas Office
Yes
Total Employees
101 - 200 People