NAP-57A Catalytic Type Flammable Gas Sensor
NAP-57A Catalytic Type Gas Sensor Description
NAP-57A is a newly developed catalytic type gas sensor based on conventional type NAP-56A for not only residential but also commercial or semi-industrial applications because of having highly excellent poisoning resistivity. Since its power consumption and pin positions are completely the same as NAP-55A and 56A, it is easily replaceable as it is. However, it does not possess the explosion proof by itself, then it is recommended to install it into an explosion proof chamber for actual application.
NAP-57A Catalytic Type Gas Sensor Features
• Good stability
• Excellent repeatability and detection accuracy
• Good linearity against gas concentration at wide range
• Quite excellent poisoning resistivity
• Down sizing for design flexibility of gas alarm or detector
NAP-57A Catalytic Type Gas Sensor Usage
• Gas alarm or detector of general combustible gases for all applications
• Gas densitometer
• Driving module for gas leakage detector
NAP-57A Catalytic Type Gas Sensor Maximum ratings
| Supply voltage to sensor |
AC 3.3V (50 - 60Hz) DC 3.3V |
| Ambient temperature and humidity in operation Temperature Humidity |
-40 ~ +80℃ less than 99%RH (without dew condensation) |
| Ambient temperature and humidity in storage Temperature Humidity |
-40 ~ +80℃ less than 99%RH (without dew condensation) |
NAP-57A Catalytic Type Gas Sensor Ratings
| Supply voltage to sensor |
AC 2.5 ± 0.25V(50-60Hz) DC 2.5 ± 0.25V |
| Current(when 2.5V is supplied) |
AC 160 ~ 180mA(50-60Hz) DC 160 ~ 180mA |
| Ambient temperature and humidity in operation Temperature Humidity |
-20 ~ +60℃ less than 95%RH (without dew condensation) |
| Ambient temperature and humidity in storage Temperature Humidity |
-30 ~ +70℃ less than 99%RH (without dew condensation) |
NAP-57A Catalytic Type Gas Sensor Detection range
It can measure/detect whole combustible gases less than 100%LEL, however the excellent accuracy of linearity within +/-10% can be obtained less than 50%LEL.
NAP-57A Catalytic Type Gas Sensor Response and recovery time
| From clean air to 10%LEL |
T90 : less than 10sec. |
| From gas to clean air |
T90 : less than 20sec. |
Send Inquiry to This Supplier
You May Also Like
-
Figaro Oxygen Sensor SK-25FNegotiableMOQ: 1 Piece
-
O2I-Flex Oxygen Sensor Interface BoardNegotiableMOQ: 1 Piece
-
TGS2600 Air Quality Sensor for The Detection of Air ContaminantsUS$ 3.5 - 5MOQ: 1 Piece
-
TGS2602 - For The Detection of Air ContaminantsUS$ 1 - 1MOQ: 1 Piece
-
TGS2603 Air Quality Sensor For Detection of Odor and Air ContaminantsNegotiableMOQ: 1 Piece
-
Electrochemical O2 Gas Sensor Oxygen Sensor O2-A2US$ 1 - 1MOQ: 1 Piece
-
TGS2620 - For The Detection of Solvent VaporsUS$ 1 - 1MOQ: 1 Piece
-
LuminOx Fluorescence-based Optical Oxygen O2 Sensor LOX-02US$ 60 - 70MOQ: 1 Piece
-
Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas SensorsUS$ 1 - 1MOQ: 1 Piece
-
CGM6812-B00 Pre-calibrated Combustible Gas Sensor ModuleNegotiableMOQ: 1 Piece