Home > Products > Gas sensor > EE893 Digital NDIR CO2 Sensor Module for OEM Applications
EE893 Digital NDIR CO2 Sensor Module for OEM Applications
- 1000 Piece / Pieces per Month
- HK
- T/T PayPal
- 7 days
- HCL-B1 Electrochemical Hydrogen Chloride Sensor (HCL Sensor)
- ETO-B1 Electrochemical Ethylene Oxide Sensor (ETO Sensor)
- CM9 Electrochemical Carbon Monoxide Sensor (CO Sensor)
- 850081DOK Dissolved Oxygen Meter Kit
- PSMU Series PM2.5/PM1.0 Particle Sensor
- CM8 Electrochemical Carbon Monoxide Sensor (CO Sensor)
Product Details
Brand Name: | E+E | Place of Origin: | Austria | Model Number: | EE893 |
Usage: | Gas Sensor | Theory: | Other, NDIR Gas Sensor |
Product Description
EE893 Digital CO2 Sensor Module for OEM Applications
The E+E CO2 module EE893 is designed for OEM applications and for demanding environment. A multiple point CO2 and temperature adjustment procedure leads to excellent CO2 measurement accuracy over the entire temperature working range; this is a must for process control and outdoor applications.
The E+E dual wavelength NDIR CO2 sensing procedure compensates automatically for ageing effects. EE893 is highly insensitive to pollution and offers outstanding long term stability.
With its small dimensions and electrical connection via contact pins and pads, EE893 is the optimal choice for OEM devices such as wireless transmitters, hand-helds or data loggers. The measured data, with a range of up to 10000ppm, is available on the E2 digital interface.
An optional kit facilitates easy configuration and adjustment of the module. The measurement interval can be set according to the application requirements; by this the average current consumption can be reduced to less than 60μA for battery-operated devices.
EE893 Digital NDIR CO2 Sensor Module Typical Applications
• Data loggers
• Hand helds
• Wireless transmitters
• Building management
• Demand controlled ventilation
EE893 Digital CO2 Sensor Module Key Features
• Autocalibration
• Outstanding long-term stability
• Temperature compensation
• Low power consumption
• Very small size
EE893 Digital NDIR CO2 Sensor Module Technical Data
Measured values | |||||||
CO2 | |||||||
Measurement principle | Dual wavelength (non-dispersive infrared technology) NDIR | ||||||
Working range | 0 - 2000 / 5000 / 10000ppm | ||||||
Accuracy at 25°C and 1013mbar) (77°F and 14.69psi) | 0- -2000ppm: | <± (50ppm +2% of measuring value) | |||||
0 - 5000ppm: | <± (50ppm +3% of measuring value) | ||||||
0 - 10000ppm: | <± (100ppm +5% of measuring value) | ||||||
Response time t90 | 105s with measured data averaging (smooth output) 60s without measured data averaging | ||||||
Temperature dependency | typ. 1ppm CO2/°C (-20~45°C) (-4~113°F) | ||||||
Calibration interval | >5 years | ||||||
Measuring time interval | adjustable from 15s up to 1h (factory setting: 15s) | ||||||
General | |||||||
Digital interface | E2 ( details: www.epluse.com) | ||||||
Supply voltage | 4.75 - 7.5V DC | ||||||
Average power consumption | 58µA (at 1h measurement interval) ~ 3.7mA (at 15s measurement interval) | ||||||
Peak current | see power consumption graph | ||||||
Electrical connection | contact pins, edge card socket (e.g. type MEC1-108-2) | ||||||
Working conditions | -40~60°C (-40~140°F) | 0~95% RH (not condensating) | 85~110kPa (12.33~15.95psi) | ||||
Storage conditions | -40~60°C (-40~140°F) | 0~95% RH (not condensating) | 70~110kPa (10.15~15.95psi) |
Contact Us
- Shenzhen Isweek Ltd.
- Contact nameMs Rita yu
- Phone86-755-83289036
- Address16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1st Rd, Hi-Tech Park, Nanshan Shenzhen,Guangdong
- DO6400/DO7400 Series Submersible Galvanic Dissolved Oxygen Sensor
- 850039 Datalogging Conductivity/TDS Meter
- AM2322 Temperature and Humidity Sensor
- MMS-D010 ORAKEL Chlorine Sensor Water Quality Sensor
- CAEL-HT Series Multi-function Humidity and Temperature Transmitter
- LEPTON Single Element Uncooled VPD PbSe Detector
- TD40 Wireless Particle Monitor
- SF800-6 High Pressure Flow Meter
- SF800 Low Pressure Flow Meter
- EOPD-150-0-2.5 UV Photodiode
- HTG3513CH Voltage Output Temperature and Humidity Sensor
- CAEL-S16 Probe Humidity and Temperature Transmitter
- MMS-D016 ORAKEL COD/TOC Sensor Waste Analyser
- SH Thin-film Humidity Sensing Element Humidity Sensors
- 4S Rev. 2 CiTiceL Electrochemical Sulfur Dioxide Gas Sensor (SO2 Sensor)
- COH-A1 Carbon Monoxide/ Hydrogen Sulfide Sensor (CO/H2S Sensor)
- NO2-A1 Electrochemical Nitrogen Dioxide Sensor (NO2 Sensor)
- NH3 3E 100 3-Electrode Ammonia Sensor (NH3 Sensor)
Popular Searches
Find Similar Products By Category
- Electronic Components & Supplies > Active Components > Sensors
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Ms Rita yu
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-