Self Operated Micro Pressure Control Valve (GAV230)
1. Self Operated Pressure regulating Valve Introduction
GAZZC, GAZZV series self operated difference (micro) Pressure Control Regulating valve Can be used in nominal pressure PN0.1 , PN10. The difference (micro) ) presses the regulation of segmenting. From 50mm.WC to 0.1MPa. self operated type difference (micro) ) Regulating valve of the pressure The use is very extensive, can be used in industry's combustion furnace system, control two kinds of supplies , such as coal gas , air discharge matching , burn in order to reach the ideal. Used in the sealed oil system of the hydrogen-cooled generating set , it is bad to control the pressure among the sealed oil and hydrogen, so as to ensure and seal reliably. Act as Difference presses the valve End not low-voltage the coherent Press the valve a little (Difference presses the valve to shoulder and press, the end is pressed, strength is zero).
2. Self Operated Pressure Control Regulating valve Characteristic
2.1 Do not need to stop producing and can go on adjustment of the establishing value;
2.2 There is no packing , exist not gritting at being have , not last activity valve stem,on seal more reliable
2.3 The sensitive element of executive body is extremely sensitive , the pinpoint pressure will be detected out while changing
2.4 The valve body is Stone's form , therefore K, B type body of a kind of valve very in common use
3. Regulating valve of the pressure Main technical parameter and performance index ( Form one)
Specified journey (mm) |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
|
Nominal pressure PN ( MPa) |
GAZZCP/GAZZVP |
8 |
11 |
20 |
32 |
50 |
80 |
100 |
160 |
GAZZCN |
53 |
83 |
|||||||
Specified journey (mm) |
6 |
8 |
10 |
15 |
20 |
||||
Nominal pressure PN (MPa) |
0.10 1.0 |
||||||||
Difference presses the range of regulating (KPa) |
0.5~5.5 5~10 9~14 13~19 18~24 |
||||||||
Medium temperature (degrees Centigrade) |
≤ 80 |
||||||||
|
≤ 10 |
||||||||
Allow the letting out amount (L/H ) |
GAZZCP/GAZZVP |
The specified capacity of 10-4* valves (IV grade) |
|||||||
GAZZCN |
The specified capacity of 5* 10-3* valves (II grade) |
||||||||
4. Dimension of the Self Operated Control Valve : mm
Nominal and open directly (DN) |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
|
A |
308 |
394 |
308 |
394 |
308 |
394 |
394 |
394 |
|
H |
GAZZCP/GAZZVP |
376 |
465 |
365 |
445 |
445 |
490 |
490 |
510 |
GAZZCN |
536 |
536 |
570 |
590 |
|||||
L |
GAZZCP/GAZZVP |
150 |
160 |
180 |
20 |
230 |
290 |
310 |
350 |
GAZZCN |
222 |
222 |
310 |
350 |
|||||
Weight (kg) |
12 |
13 |
15 |
17 |
20 |
28 |
38 |
43 |
|
Lead and press and is in charge of the whorl to connect |
M16* 1.5 |
||||||||
Send Inquiry to This Supplier
You May Also Like
-
Thermostatic Self-Actuated Temperature Regulating ValveUS$ 2 - 50MOQ: 10 Pieces
-
8/5000 Handwheel Pound Power Station Gate ValveUS$ 2 - 50MOQ: 10 Pieces
-
High-temperature High-pressure Power Station Check ValveUS$ 2 - 50MOQ: 10 Pieces
-
High-temperature and High-pressure Power Station Check ValveUS$ 2 - 50MOQ: 10 Pieces
-
Electric High-pressure and High-temperature Power Station Gate Valve, GAJ61Y-P59US$ 2 - 50MOQ: 10 Pieces
-
High-temperature Power Plant ValvesUS$ 2 - 50MOQ: 10 Pieces
-
ASI Swing Check Valve Power Station ValveUS$ 2 - 50MOQ: 10 Pieces
-
Y Type Welding High Temperature Power Station Valve H61Y-P91US$ 2 - 50MOQ: 10 Pieces
-
Flange High Pressure Globe Valves Power Station ValvesUS$ 2 - 50MOQ: 10 Pieces
-
High-temperature High-pressure Power Station Check ValveUS$ 2 - 50MOQ: 10 Pieces