TCSTX Menu Driven Loop-Powered Toroidal Conductivity Transmitter
TCSTX - Menu Driven Loop-Powered Toroidal Conductivity Transmitter with 4-20mA Isolated Output and Local Display
TCSTX Toroidal Conductivity Transmitter Features
• 4-20mA isolated output, loop powered 16 - 35VDC
• Large dual segmented high content display indicates conductivity & process temperature simultaneously
• User-adjustable temperature compensation (0 - 4% / deg C)
• Four-key menu driven, field selectable ranges
• Adjustable zero and span
• Nema 4X enclosure with multiple mounting configurations
TCSTX Toroidal Conductivity Transmitter Description
The model TCSTX is designed for on-line monitoring of water treatment applications and aggressive process chemicals. This four-key menu driven transmitter with local display is ideally suited for applications where 4-20mA signals are required and reliable instrumentation is critical.
Key features include: the menu driven field selectable measuring ranges, large dual segment high content display, adjustable temperature compensation (% deg C), isolated output and reversible cell drive.
A NEMA 4X (IP66) enclosure provides excellent durability. A variety of mounting choices are available for wall, panel, pipe or rail installation.
Pair the TCSTX with a TCS3020 toroidal sensor for troublefree service. TCS3020 sensors are offered in Noryl construction and can be mounted in a custom CPVC flow cell (p/n: FC95C) for in-line use.
TCSTX Toroidal Conductivity Transmitter Specifications-Transmitter
| Full Scale Range |
0-2,000 uS / 2.000 mS / 20.00 mS / 200.0 mS / 2000 mS - User selectable |
| Sensitivity |
0.05% of span or 0.1uS, whichever is greater |
| Repeatability |
0.3% of span, or 0.1uS, whichever is greater |
| Non-Linearity |
0.3% of span or 0.1uS, whichever is greater |
| Zero Driftx |
|
| Operating Conditions |
-20 to 60 deg C (-4 to 140 deg F), 0-95% R.H. non-condensing conditions |
| Storage Conditions | -30 to 70 deg C(-22 to 158 deg F), 0-95% R.H. non-condensing conditions |
| Location |
Designed for hazardous and non-hazardous areas |
| EMI/RFI Influence |
Designed to EN 61326-1 |
| Temperature Drift |
Span or zero, 0.03% of range/deg C |
| Stability |
0.1% of span per 24 hours |
| Power Requirement |
16-35 VDC (2-wire device) |
| Warm-Up Time |
7 seconds to rated performance |
| Response time |
6 seconds to 90% step input at lowest setting |
| Output Isolation |
600 V galvanic isolation |
| Filter |
Adjustable, 0-9.9 minutes additional dampening to 90% step input |
| Enclosure |
NEMA 4X (IP66) polycarbonate, wall, pipe or DIN Rail mount. |
| Display |
Large, high-contrast, Super-Twist (STN) LCD 4-digit main display with sign,
|
| Keypad |
4-key membrane type with tactile feedback, polycarbonate with UV coating,
|
| Weight |
1lb (0.45Kg) |
| Conduit Openings |
2 each PG-9. Cord grips included. |
| Temperature Input | Selectable Pt100RTD or Pt1000RTD. ATC is user selectable 0-4%/Deg C |
| Maximum Cable Length |
200ft. (61.0m) |
TCSTX Toroidal Conductivity Transmitter Ordering Information
| Part Number |
Description |
| TCSTX |
Loop-powered, 4-20mA toroidal conductivity transmitter (16-35VDC power supply not included) |
|
TCS3020 |
Keyed Noryl toroidal conductivity sensor. Includes 20ft of cable and tinned wire terminations |
| FC95C |
Keyed CPVC flow cell for TCS-2030. Includes nut and o-ring seal |
Send Inquiry to This Supplier
You May Also Like
-
DT-625 Digital Humidity & Temperature MeterNegotiableMOQ: 1 Piece
-
GUVx-T1xGS2-3LW10 UV Radiometer 2.0NegotiableMOQ: 1 Piece
-
TCSMA Loop-Powered, Isolated Toroidal Conductivity TransmitterNegotiableMOQ: 1 Piece
-
P311 Handheld Particle CounterNegotiableMOQ: 1 Piece
-
GUVB-S11GS-AG03.4 Outdoor UV Index MeterNegotiableMOQ: 1 Piece
-
P230 Remote Particle CounterNegotiableMOQ: 1 Piece
-
IMR EX610 SMART Sensor Gas DetectorNegotiableMOQ: 1 Piece
-
XEN-TCG3880 Thermal Conductivity SensorNegotiableMOQ: 1 Piece
-
TF-LP01 Laser Particle SensorNegotiableMOQ: 1 Piece
-
EEH110 Digital Humidity and Temperature Sensor With 5 V Supply VoltageNegotiableMOQ: 1 Piece