Home > Instruments & Meters > Meter for Liquid & Gas > Flow Meter > Proline Prowirl R 200 Vortex Flowmeter

Proline Prowirl R 200 Vortex Flowmeter

Proline Prowirl R 200 Vortex Flowmeter photo-1
Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Place of Origin:
Germany
Model Number:
R 200
Payment & Shipping
Payment Methods:
Port of Shipment:
Xi'an
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Germany
Model Number R 200

Proline Prowirl R 200 Vortex flowmeter

Same accuracy despite line size reduction, available as compact or remote device version

Product Overview

 

The reducer version Prowirl R provides an integrated reduction of the line size by 1 or 2 diameters and therefore offers an improved low flow performance. Prowirl R 200 offers industry-compliant two-wire technology for seamless integration into existing infrastructures and control systems. Additional advantages are high operational safety in hazardous areas thanks to an intrinsically safe design, and a familiar installation procedure.

Benefits

  • Integrated temp. measuring for mass/ energy flow of saturated steam (opt.)

  • Cost and time saving – no pipework modifications needed for line size reduction

  • High availability – proven robustness, resistance to vibration, temperature shocks and water hammer

  • No maintenance – lifetime calibration

  • Convenient device wiring – separate connection compartment

  • Safe operation – no need to open the device due to display with touch control, background lighting

  • Integrated verification – Heartbeat Technology™

Field of application

  • Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)

Device properties

  • Integrated diameter reduction by 1 or 2 line sizes

  • Nominal diameter (mating pipe) up to DN 250 (10")

  • Installation length according to industry standard

  • Display module with data transfer function

  • Robust two-chamber housing

  • Plant safety: worldwide approvals (SIL, Haz. area)

  • Technical information

 

Measuring PrincipleVortex
Product headlineThe flowmeter with the same accuracy despite line size reduction, available as compact or remote version. Integrated temperature measurement for mass/energy flow of saturated steam. Dedicated for applications with very low or reduced flow.
Sensor featuresCost and time saving – no pipework modifications needed for line size reduction. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. No maintenance – lifetime calibration. Integrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10").
Transmitter featuresConvenient device wiring - separate connection compartment. Safe operation - no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology™. Display module with data transfer function. Robust two-chamber housing.
Nominal diameter rangeDN 25 to 250 (1 to 10")
Wetted materialsMeasuring tube: 1.4408 (CF3M)
DSC sensor: 1.4435 (316/316L)
Connection: 1.4404 (F316/F316L)
Measured variablesVolume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
Max. measured errorVolume flow (liquid): ±0.75 %
Volume flow (steam, gas): ±1.00 %
Mass flow (liquid): ±0.85%
Mass flow (steam, gas): ±1.7 %
Measuring rangeLiquid: 0.26 to 545 m³/h (0.15 to 321 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 3.6 to 7262 m³/h (2.12 to 4274 ft³/min
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
Max. process pressurePN 40, Class 300, 20K
Medium temperature rangeStandard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
Ambient temperature rangeCompact version (standard): –40 to +80 °C (–40 to +176 °F)
Compact version (option): –50 to +80 °C (–58 to +176 °F)
Remote version (standard): –40 to +85 °C (–40 to +185 °F)
Remote version (option): –50 to +85 °C (–58 to +185 °F)
Sensor housing materialSensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
Transmitter housing materialAlSi10Mg, coated; 1.4404 (316L)
Degree of protectionCompact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, type 4X enclosure
Display/Operation4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs4-20 mA HART (passive)
4-20 mA (passive)
Pulse/frequency/switch output (passive)
Inputs4-20 mA (passive)
Digital communicationHART, PROFIBUS PA, FOUNDATION Fieldbus
Power supplyDC 12 to 35 V (4-20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4-20 mA HART, 4-20 mA)
DC 12 to 35 V (4-20 mA HART, pulse/frequency/switch output, 4-20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
Hazardous area approvalsATEX, IECEx, cCSAus
Other approvals and certificates3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, functional safety
PED, CRN, AD 2000
NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614-1, similar to ASME IX (on request)

 

 

 

 

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
2010
Factory Size
1,000-3,000 square meters
Total Employees
101 - 200 People

Recommended Categories