Fully Automatic Control Liquid Chlorine System With 1-year Warranty and On-site Training
Product Spotlights
Tianjin ZhuoLiNeng (ZLN) Technology Co., Ltd., a professional manufacturer of water treatment equipment, proudly presents our Fully Automatic Control Liquid Chlorine System. Designed for precision disinfection and safe operation, this system integrates advanced PLC control, reliable dosing pumps, and robust safety features to ensure consistent chlorine delivery in municipal, industrial, and commercial water treatment applications. With a 1-year warranty and on-site training provided by our experienced engineers, you can trust ZLN to deliver a turnkey solution that minimizes downtime and maximizes efficiency. Our factory, located in Tianjin, China, serves customers across North America, South America, Europe, Africa, Asia, and Oceania, ensuring global support and fast shipping from Tianjin Port.
Key Features & Technical Specifications
Fully Automatic PLC Control: The system utilizes a programmable logic controller (PLC) with touch-screen HMI for real-time monitoring, automatic dosing adjustment based on flow or residual chlorine feedback, and alarm functions.
High-Precision Dosing Pump: Equipped with a corrosion-resistant diaphragm or peristaltic pump, ensuring accurate liquid chlorine injection from 0.1 to 200 kg/h (customizable).
Multi-Level Safety Protection: Includes leak detection, emergency shut-off, pressure relief valves, and automatic ventilation to prevent chlorine gas escape.
Durable Material Construction: Wetted parts are made of PVC, UPVC, or stainless steel 316L to resist chlorine corrosion; external cabinet is powder-coated steel.
Remote Monitoring & Control: Optional SCADA/Modbus communication for integration with existing plant DCS systems.
Energy-Efficient Design: Variable frequency drive (VFD) on pump motor reduces power consumption by up to 30%.
Easy Maintenance: Quick-disconnect fittings, transparent feed lines, and accessible filter housing simplify routine service.
| Parameter | Specification |
|---|---|
| Chlorine capacity | 10 – 200 kg/h (customizable) |
| Control accuracy | ±1% of setpoint |
| Power supply | 220V / 380V, 50/60Hz, 3-phase |
| Operating temperature | 0°C – 50°C |
| Protection class | IP54 (control panel), IP65 (pump unit) |
| Warranty | 1 year (parts & labor) |
| Training | On-site training (up to 2 days) |
Benefits for Your Operation
Reduce Chemical Waste: Automatic dosing based on real-time demand saves up to 20% chlorine consumption compared to manual systems.
Improve Water Quality: Consistent residual chlorine levels ensure effective disinfection and compliance with health standards.
Lower Labor Costs: Fully automated operation frees your staff from manual monitoring and adjustment.
Enhanced Safety: Built-in leak detection and emergency protocols protect operators and the environment.
Quick Installation & Commissioning: Pre-assembled, skid-mounted unit reduces site work; our engineers provide on-site training to ensure smooth handover.
Why Choose ZLN?
As a manufacturer with years of experience in water treatment automation, Tianjin ZhuoLiNeng Technology Co., Ltd. has supplied equipment to numerous projects across North America, South America, Europe, Africa, Oceania, and Asia. Our factory in Tianjin, China, enables competitive pricing and fast delivery from Tianjin Port. We are committed to quality: every system undergoes rigorous testing before shipment. The 1-year warranty covers parts and labor, and our on-site training ensures your team can operate and maintain the system with confidence. We also offer remote technical support and spare parts availability. Contact us today to discuss your liquid chlorine dosing requirements—we can customize the system to match your specific flow rate, chlorine demand, and integration needs.
Frequently Asked Questions (FAQ)
Q: What types of water treatment plants can use this system?
A: Our system is suitable for municipal drinking water plants, wastewater treatment facilities, swimming pools, cooling water systems, and industrial process water. It can handle both small and large flow rates.Q: Do I need special safety equipment for liquid chlorine storage?
A: Yes, liquid chlorine requires proper storage in a well-ventilated area with gas detection. Our system integrates with your existing chlorine cylinder or tank, and we provide leak detection and emergency shut-off as standard.Q: Can the system be integrated with my existing SCADA?
A: Yes, it supports Modbus RTU/TCP, Profibus, and other common protocols. Please specify your communication requirements when ordering.Q: How long does on-site training take?
A: Typically 1–2 days, depending on the complexity of your system. Our engineers will train your operators on normal operation, calibration, troubleshooting, and maintenance.Q: What is the warranty period and what does it cover?
A: We offer a 1-year comprehensive warranty covering defects in materials and workmanship. The warranty excludes consumables (e.g., diaphragms, seals) and damage caused by misuse or improper installation.Q: Can I get a custom capacity?
A: Absolutely. Our system is modular and can be designed for chlorine dosing rates from 10 kg/h up to 200 kg/h or more. Contact us with your specific requirements.Q: How do I order spare parts?
A: Spare parts are available from our factory or local distributors. We provide a recommended spare parts list with each system.Q: Is this system suitable for outdoor installation?
A: The standard unit is designed for indoor use (IP54). For outdoor installation, we can provide weatherproof enclosures (IP65/66) upon request.
Send Inquiry to This Supplier
You May Also Like
-
Fully Automatic Sodium Hypochlorite Production Plant With Standard Compliant and Mill Test ReportUS$ 100000 - 2000000MOQ: 1 Set
-
Skid Mounted Plug-Play Sodium Hypochlorite Unit With 1 Year Warranty and Technical SupportUS$ 100000 - 2000000MOQ: 1 Set
-
Sodium Hypochlorite System With Less Investment on Salt and Fully Automatic OperationUS$ 100000 - 2000000MOQ: 1 Set
-
Sodium Hypochlorite Production System With Salt Purity Requirement NACL>89% Less InvestmentUS$ 100000 - 2000000MOQ: 1 Set
-
Fully Automatic Sodium Hypochlorite Generator 5%-15% Concentration Skid Mounted Plug-PlayUS$ 100000 - 2000000MOQ: 1 Set
-
Plug-Play Sodium Hypochlorite Unit 5%-15% Concentration for Industrial Bleaching ApplicationUS$ 100000 - 2000000MOQ: 1 Set
-
Fully Automatic Sodium Hypochlorite Generator With PLC Control and Skid Mounted Plug-Play Design for 5%-15% ConcentrationUS$ 100000 - 2000000MOQ: 1 Set
-
Fully Automatic Sodium Hypochlorite Production System With PLC Control, Skid Mounted Design, and 5%-15% RangeUS$ 100000 - 2000000MOQ: 1 Set
-
Skid Mounted Plug-Play Sodium Hypochlorite System for 5%-15% Concentration With Fully Automatic ControlUS$ 100000 - 2000000MOQ: 1 Set
-
PLC Controlled Sodium Hypochlorite Generator With Fully Automatic Operation and Skid Mounted Plug-Play DesignUS$ 100000 - 2000000MOQ: 1 Set



