Honeywell CC-TCNT01 Controller Input Output Termination Assembly
Honeywell CC-TCNT01 Controller Input Output Termination Assembly
The Honeywell CC-TCNT01 (part number 51304592-100) is an Input/Output Terminal Assembly (IOTA) for the C300 controller in the Experion PKS system. It provides the controller with 24V DC power supply distribution and physical wiring interfaces, and supports critical connections such as FTE fault-tolerant Ethernet, redundant links, I/O communication, and time synchronization. It is a core adapter component that ensures stable interconnection between the controller and I/O modules and operator stations, and is suitable for high-reliability control scenarios in continuous production industries such as chemical and power industries.
Email: xmxblynn@163.com
Phone: +86 18059884797
Core Parameters and Specifications
Item Parameters
Product Type C300 Controller IOTA (Input/Output Terminal Assembly)
Compatible System Honeywell Experion PKS Distributed Control System, compatible with C300 controller
Power Supply Specifications 24V DC±10%, output current ≤300mA, powering the controller and I/O modules
Core Interfaces Supports FTE Ethernet, I/O links, redundancy, battery, time source, and other cable termination connections
Redundancy Support Compatible with C300 dual-controller redundancy configuration, link fault switching <50ms
Physical Characteristics Standard IOTA size, compatible with C300 controller chassis, screw terminal wiring (compatible with 14-22AWG wire)
Environmental Tolerance Operating temperature 0℃-60℃, storage temperature -40℃-85℃, 5%-95% non-condensing humidity
Core Components Includes power distribution circuit, communication interface circuit, diagnostic monitoring unit, supports hot-swappable maintenance
Core Functions
Power Distribution and Power Supply Assurance: Precisely distributes 24V DC power to the C300 controller module, ensuring stable power supply to the controller and I/O modules. This is the fundamental guarantee for a system without external power supply failure points.
Multi-Type Cable Termination Integration: Integrates physical and electrical interfaces for FTE, I/O links, redundancy, batteries, time sources, and other cables, unifying the management of various external connections to the controller and simplifying wiring and maintenance.
Redundant Communication and Fast Switching: Adapts to the C300 dual-controller redundancy architecture, supports FTE fault-tolerant Ethernet redundant links, and achieves link failure switching of <50ms, ensuring seamless operation of control logic and improving system availability.
Diagnostics and Status Monitoring: Monitors power supply status, communication link health, and hardware operating status in real time, providing fault early warnings for preventative maintenance and rapid troubleshooting.
I/O Communication Adaptation: Serves as the connection backplane between the controller and C-series I/O modules, ensuring high-speed, deterministic transmission of control commands and field data, supporting multi-loop adjustment and complex logic control.
Functions, Applications, and Typical Scenarios
**Industrial Process Control Core Adaptation:** In petrochemical, fine chemical, and other scenarios, it connects sensors and actuators for temperature, pressure, and flow rates, enabling precise parameter control through the C300 controller. This ensures stable reaction processes and improves product quality and efficiency.
**Power Production and Monitoring:** Used to connect power plant generator monitoring equipment to the C300 controller, transmitting data such as speed, vibration, and temperature. It supports speed control and safety protection, adapting to the continuous operation requirements of generator units.
**Redundant System High Availability Deployment:** In continuous production scenarios requiring over 99.99% availability, the dual C300 controller redundancy configuration, through rapid link switching and stable power supply, avoids production interruptions caused by single-point failures.
**Simplified System Installation and Maintenance:** Unified management of various cable terminals reduces wiring errors, supports hot-swappable maintenance, shortens equipment repair and replacement time, and reduces operation and maintenance costs.
**Data Interaction and Time Synchronization:** Ensures FTE communication between the controller and operator stations and I/O modules, supports time source synchronization, and ensures the consistency and determinism of data transmission in the distributed control network.
Email: xmxblynn@163.com
Phone: +86 18059884797
Other related product models recommended:
CC-TAOX61
CC-TAOX01
CC-TDIL01
CC-TAIM01
CC-TAIN01
CC-TAIN11
CC-TAIX51
CC-TAON01
CC-TAON11
CC-TAO×11
CC-TDlL01
CC-TDlL11
CC-TDOB11
CC-TDOR01T
CC-TDOB01 51308371-175
CC-TDI220
Send Inquiry to This Supplier
You May Also Like
-
Honeywell FC-TSDI-1624 Digital Input ModulecUS$ 10000 - 15000MOQ: 1 Combo
-
Honeywell FC-PSU-UNI2450U-V2.1 High-performance General-purpose Power ModulesUS$ 10000 - 15000MOQ: 1 Combo
-
Honeywell FC-IOCHAS-0002S Non-redundant I/O ChassisUS$ 10000 - 15000MOQ: 1 Combo
-
Honeywell BSFC-02C Charging Control BoardUS$ 10000 - 15000MOQ: 1 Combo
-
Honeywell FC-IOCHAS-0001S High-speed Data Interaction With the ControllerUS$ 10000 - 15000MOQ: 1 Combo
-
Honeywell FC-TUIO52 High-speed Communication of ControllerUS$ 10000 - 15000MOQ: 1 Combo
-
FC-QPP-0001 Quad-core Processor Package Module Four Bus Drivers Are Used to Drive the IO ChassisNegotiableMOQ: 1 Bag
-
H92A0K9VOH00 Communication Module It Has a Good Modular DesignNegotiableMOQ: 1 Bag
-
FS-OPP-0002 Processor MultitaskNegotiableMOQ: 1 Bag
-
FC-QPP-0002 Quad-core Processor Methods to Improve Actual Hardware CoverageNegotiableMOQ: 1 Bag