Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Material:
Other, Ductile Iron Body, Stainless Steel Trim
Size Range:
DN50 to DN200 (2“ to 8“)
Connection Type:
Flanged End
Payment & Shipping
Payment Methods:
Port of Shipment:
Shanghai, China
Delivery Detail:
7 days
Material Other, Ductile Iron Body, Stainless Steel Trim
Size Range DN50 to DN200 (2“ to 8“)
Connection Type Flanged End
Max Inlet Pressure 25 bar (362 psi)
Outlet Pressure Range 1.5 to 7 bar adjustable
Application HVAC Systems, Fire Protection Networks
Model Series S200x Compact Series
Function Precise Pressure Reduction, Water Hammer Prevention

Shanghai Sote Valve Co., Ltd., a professional valve manufacturer based in Shanghai, China, proudly presents the Compact S200x Series Water Pressure Reducing Valve. Engineered for superior performance in critical water systems, this valve ensures stable downstream pressure control while protecting pipelines from damage caused by excessive pressure. Its robust construction and intelligent design make it an indispensable component for modern building services.

Core Technical Specifications:

  • Precision pressure regulation maintains consistent downstream pressure within ±5% deviation
  • Self-actuating diaphragm mechanism eliminates external power requirements
  • Stainless steel internal components resist corrosion in potable water systems
  • Compact design requires 30% less installation space than conventional valves
  • Integrated strainer protects trim from particulate damage

Performance Parameters Table:

Model Size (DN) Max Flow Rate (m³/h) Operating Temp
S200x-50 50 30 0-80°C
S200x-100 100 120 0-80°C
S200x-200 200 480 0-80°C

Engineering Advantages:

  • Water hammer suppression through gradual pressure adjustment prevents pipe bursts
  • Energy savings by reducing unnecessary pump head pressure
  • Maintenance-friendly design with top-access cover for servicing without pipe disassembly
  • Fail-safe operation maintains pressure control even during flow fluctuations

Trusted by engineering firms across Asia, Shanghai Sote Valve combines rigorous quality control with extensive hydraulic system expertise. Our manufacturing facility in Shanghai utilizes advanced CNC machining centers to ensure dimensional accuracy in every valve component. The S200x Series has undergone 10,000-cycle endurance testing to verify long-term reliability in demanding fire protection scenarios.

For building managers and MEP contractors, this valve delivers measurable benefits: reduced maintenance costs from fewer pipe joint failures, compliance with pressure requirements in high-rise buildings, and extended service life of downstream equipment. Contact our Shanghai technical team today to discuss how our pressure reducing valves can optimize your HVAC or fire suppression system performance.

Frequently Asked Questions:

  1. Q: Can this valve handle variable flow conditions in HVAC systems?
    A: Yes, the balanced diaphragm design maintains precise pressure control across 10-100% flow rate variations.
  2. Q: Is the valve suitable for both hot and cold water applications?
    A: Absolutely, the standard version operates reliably in 0-80°C environments. High-temperature models are available upon request.
  3. Q: How often does the strainer require cleaning?
    A: Maintenance intervals depend on water quality. We recommend quarterly inspection during initial operation, with adjustments based on observed debris accumulation.
  4. Q: Can the outlet pressure be adjusted while the system is operating?
    A: Yes, the external adjustment knob allows pressure setting changes without shutting down the pipeline.
  5. Q: What is the typical delivery lead time for DN150 valves?
    A: Standard sizes ship within 2 weeks from our Shanghai warehouse. Contact sales for expedited options.
  6. Q: Does the valve require vertical installation orientation?
    A: Horizontal installation is acceptable, but vertical mounting with upward flow direction optimizes performance.
Product Tags: Water Pressure Reducing Valve , HVAC Pressure Regulator , Fire Protection Pressure Control Valve