Home > Electrical & Electronics > Relay & Contactor > Relay > ABB PFEA113-65 (3BSE028144R0065) – Tension/Force Measurement Electronics for Pressductor Load Cells

ABB PFEA113-65 (3BSE028144R0065) – Tension/Force Measurement Electronics for Pressductor Load Cells

ABB PFEA113-65 (3BSE028144R0065) – Tension/Force Measurement Electronics for Pressductor Load Cells photo-1
ABB PFEA113-65 (3BSE028144R0065) – Tension/Force Measurement Electronics for Pressductor Load Cells photo-2
ABB PFEA113-65 (3BSE028144R0065) – Tension/Force Measurement Electronics for Pressductor Load Cells photo-3
US$ 2560.00 ≥1 Blade
Key Specifications
Get Latest Price
I/O Number:
ABB PFEA113-65
Model Number:
3BSE028144R0065
Condition:
NEW
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
Delivery time depends on order quantity.
I/O Number ABB PFEA113-65
Model Number 3BSE028144R0065
Condition NEW
Warranty One Year
Package Original Packaging
HS Code 903289
Order Placement Process and Guarantees
  • Warranty: 365 days

  • Delivery: 1 week if in stock; no more than one month at the latest

  • Payment: 50% advance payment; full payment prior to delivery

  • Express options: FedEx, UPS, DHL

Key Features
  • Optimized for Pressductor load cells – Provides stable, repeatable tension signals from strain-gauge (mV/V) sensors, typically used on unwind/rewind sections.

  • Dual-channel capability – In many cases supports two load cells (left/right), with summation and balancing for accurate web tension.

  • Industrial analog outputs – 0/4–20 mA and ±10 V outputs (variant dependent) for direct drive/brake control or PLC feedback.

  • Fast response and filtering – Typical dynamic filtering helps reject mechanical vibration while keeping control response tight.

  • Digital I/O for control functions – Inputs for zero/tare and status; relay/digital outputs for alarms or interlocks (depends on configuration).

  • Fieldbus-ready – Commonly available with RS-485 (Modbus RTU); certain variants support Profibus-DP for quick PLC integration.

  • 24 VDC powered – Low-power DIN-rail solution that fits easily into existing control cabinets.

  • Service-friendly setup – Typically offers straightforward calibration, zeroing, and scaling in the field; maintenance teams appreciate the predictable behavior.

Technical Specifications
Brand / Model ABB PFEA113-65 (Material no. 3BSE028144R0065)
HS Code 9032.89 (Other automatic regulating or controlling instruments)
Power Requirements 24 VDC nominal (±10%); typically up to ~10 W
Signal Inputs Strain-gauge load cell inputs (mV/V), often 1–2 channels for Pressductor sensors
Signal Outputs Analog: 0/4–20 mA and/or ±10 V (variant dependent); digital/relay outputs for alarms/status
Communication Interfaces RS-485 (Modbus RTU); service port (often RS-232). Certain builds may support Profibus-DP.
Operating Temperature Typically 0 to +55°C (non-condensing environment)
Installation Method DIN-rail mounting (EN 60715) inside industrial control cabinet
Dimensions & Weight Compact DIN-rail enclosure; approximate weight ~0.4 kg

Notes: Interface and I/O details may vary by variant. The above reflects common characteristics for PFEA113 units used with Pressductor load cells.

D1F2A77952A7729F5FB225D562FE4249

Application Fields
  • Paper & Film Converting: Unwind/rewind stands, slitters, laminators, coaters requiring tight web tension.

  • Metals Processing: Strip lines, annealing, galvanizing and foil rolling where tension uniformity reduces defects.

  • Textiles & Nonwovens: Consistent fabric handling during dyeing, coating, or calendaring.

  • Printing & Packaging: Register-critical processes where tension stability improves print quality and waste ratios.

Advantages & Value
  • Reliability that operators trust – One thing I appreciate is how these units hold calibration over time, even with temperature swings.

  • Drop-in compatibility – The -65 variant helps maintenance teams replace without PLC rework in many cases.

  • Clean integration – Standard analog signals and Modbus/Profibus options make PLC and drive tie-in straightforward.

  • Lower lifecycle cost – Stable electronics reduce scrap from tension drift and cut unscheduled stops.

  • Global support – ABB’s ecosystem of Pressductor load cells and application notes shortens commissioning time.

Installation & Maintenance
  • Cabinet & wiring – Mount on DIN-rail inside a ventilated cabinet; keep sensor cables shielded and routed away from VFD power cables. Use a clean 24 VDC supply with proper grounding.

  • Environment – Operate in a dry, non-condensing area; typical ambient 0–55°C. Allow space around the unit for airflow.

  • Signal setup – Perform zero/tare with the web slack; scale using known load or line references. Many teams log baseline values after start-up.

  • Routine care – Check terminal tightness quarterly, verify analog scaling, and review alarm logs. Firmware updates (when available for the variant) should be scheduled during planned downtime.

  • EMC best practices – Bond shields at a single point, use twisted pairs for load cells, and separate low-level signals from motor leads to avoid noise.

Quality & Certifications
  • Compliance: CE; RoHS; UL/CSA where applicable for the specific variant

  • Manufacturing: Produced under ISO 9001 quality systems

  • Warranty: 365 days from shipment

Field feedback: A packaging customer swapped an older tension controller for PFEA113-65 during a brief shutdown. They kept the original Pressductor load cells, mapped the 4–20 mA output to the brake drive, and were back in production in under two hours. The maintenance note said scrap on delicate film fell noticeably, mostly due to steadier unwind tension.

Product Tags: ABB PFEA113-65 , 3BSE028144R0065

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Gold Verified Supplier
1Yr
Verified Business License
Business Type
Trading Company
Year Established
2014
Annual Export Value
US$2.5 Million - US$5 Million
Total Employees
51 - 100 People

Recommended Categories

Explore top categories and find suppliers for your specific needs