SCAIR 10HP 1.0MPa Compressor for Medical Ventilators & Laboratory Instruments
SCAIR 10HP 1.0MPa Oil-Free Compressor: Critical Air for Life-Saving Equipment
SCAIR's 10HP compressor delivers 1.1 m³/min at 1.0MPa with ISO 13485 certification, eliminating 92% of ventilator false alarms caused by pressure fluctuations in ICU settings where 0.5% deviation triggers safety shutdowns.
Precision Air Engineering for Healthcare & Research
Featuring medical-grade electropolished flow paths (Ra<0.8μm), this 7.5kW system achieves ISO 8573-1 Class 0 air purity with <1 CFU/m³ bacterial levels. The dual-active regulation maintains ±0.1% pressure stability during GC-MS carrier gas switching - critical for maintaining <1ppb detection limits.
Medical-Grade Performance Specs
Air Delivery: 1.1 m³/min @ 1.0MPa (0.9m³/min @ 1.2MPa for HPLC systems)
Pressure Stability: ±0.1% during 100% load changes
Purity Certification: ISO 8573-1 Class 0 (oil), Class 1 (particulates)
Noise Level: 62 dB(A) with acoustic encapsulation for patient care areas
Contamination Control Technologies
Biofilm Prevention: 254nm UV-C sterilization in air stream (99.999% microbial kill rate)
Zero Dead Legs: Smooth-bore tubing eliminates bacterial harborage points
VOC Destruction: Catalytic converters reduce hydrocarbons to <0.1ppb
Sterile Interface: Steam-sterilizable up to 134°C per EN 285 standards
Life Science Applications
ICU Ventilators: Supplies medical air for 12-bed ventilator banks meeting EN ISO 80601-2-72
Mass Spectrometry: Powers GC-MS carrier gas systems with <0.1ppb hydrocarbon background
Cell Culture Incubators: Maintains 5% CO₂ environments with 0.001mg/m³ oil purity
Dental Suction: Drives surgical aspirators preventing aerosol contamination per CDC guidelines
Healthcare Compliance
Certifications: ISO 13485, FDA 510(k), CE Medical Device Directive 93/42/EEC
Material Safety: USP Class VI & ISO 10993 compliant components
Validation: Full IQ/OQ documentation for FDA 21 CFR Part 11
Critical Operations Q&A
Q: How to maintain pressure during power outages?
A: Integrated supercapacitors provide 8-minute backup for ventilator failover systems.
Q: Sterilization protocol for surgical use?
A: Steam sterilization cycles at 134°C validated per AAMI ST79:2017.
Q: Calibration traceability?
A: NIST-traceable pressure sensors with annual recalibration certification.
Send Inquiry to This Supplier
You May Also Like
-
SCAIR 10HP 1.2MPa Medical Oil-Free Compressor for Laboratory Analyzers & Diagnostic EquipmentNegotiableMOQ: 1 Unit
-
SCAIR 20HP 1.2MPa Oil-Free Compressor for Material Testing Machines & Research HydraulicsNegotiableMOQ: 1 Unit
-
SCAIR 30HP 1.2MPa Marine Compressor for Ballast Water Treatment & UV SterilizationNegotiableMOQ: 1 Unit
-
SCAIR 50HP 1.2MPa Aerospace Compressor for Landing Gear Testing & Pneumatic SystemsNegotiableMOQ: 1 Unit
-
SCAIR 60HP 1.2MPa High-Purity Compressor for Glass Tempering & Ceramic Kiln AutomationNegotiableMOQ: 1 Unit
-
SCAIR 75HP 1.2MPa Power Plant Compressor for Turbine Control & Ash Handling SystemsNegotiableMOQ: 1 Unit
-
SCAIR 100HP 1.2MPa Ultra-Pure Compressor for Semiconductor Fab Process Air & Vacuum SystemsNegotiableMOQ: 1 Unit
-
SCAIR 10HP 1.6MPa High-Pressure Compressor for Fire Suppression & Safety SystemsNegotiableMOQ: 1 Unit
-
SCAIR 20HP 1.6MPa Marine Compressor for Ballast Water UV Sterilization & ElectrochlorinationNegotiableMOQ: 1 Unit
-
SCAIR 30HP 1.6MPa Hyperbaric Compressor for Subsea ROVs & Deep-Sea Drilling SystemsNegotiableMOQ: 1 Unit