Bay control and interlocking – Ready-made logic templates with flexible customization to enforce safe switching sequences.
Synchrocheck – Voltage inputs allow closing checks across sources, typically reducing mis-operations during energization.
IEC 61850 Ed.2 with GOOSE – Fast peer-to-peer signaling and MMS for SCADA; PRP/HSR redundancy on dual Ethernet ports is commonly available.
Rich I/O – Galvanically isolated binary inputs, high-duty relay outputs, and double-point indication handling for disconnectors/earthing switches.
Event and disturbance records – Millisecond time-stamped SOE and COMTRADE disturbance files streamline fault analysis.
Engineering via ABB PCM600 – From my experience, configuration and logic edits are straightforward, which shortens FAT/SAT cycles.
Time synchronization – SNTP and IRIG-B help keep records aligned across bays and substations.
Modular hardware – Flexible slotting to match feeder, transformer bay, or bus-tie applications; spares stocking becomes simpler.
| Brand / Model | ABB REC670 – Order code 1MRK002814-AC |
| HS Code | 853710 (commonly used for protection & control IEDs; final classification may vary by country) |
| Power Requirements | Typically 110–250 V DC or 100–240 V AC (alternative 24–60 V DC variants depending on power module) |
| Dimensions & Weight | Compact 19-inch rack/flush-mount style; approx. 4U height; weight varies by I/O configuration |
| Operating Temperature | -25°C to +55°C operation (storage typically up to +70°C) |
| Signal Input/Output Types | Binary inputs (typ. 24–250 V DC), relay outputs (NO/NC), double-point indications; VT inputs for synchrocheck/voltage measurements |
| Communication Interfaces | IEC 61850 MMS/GOOSE; dual Ethernet with PRP/HSR in many cases; SNTP/IRIG-B; optional IEC 60870-5-104, DNP3, Modbus TCP |
| Installation Method | Panel/flush mounting in switchgear cabinets; rear terminal wiring; suitable for 19-inch subrack arrangements |
Transmission and distribution bays (breaker, disconnector, earthing switch control with interlocking)
Bus-tie and coupler bays requiring dependable synchrocheck prior to closing
Industrial substations—steel, mining, oil & gas—where compact bay control simplifies retrofit projects
Renewables and IPP substations integrating IEC 61850 peer-to-peer schemes without hardwiring
Reliability – Proven Relion 670 platform, event-stable firmware, and fast failover with PRP/HSR reduce single points of failure.
Compatibility – Multi-protocol support trims gateway needs and eases SCADA integration in mixed fleets.
Lifecycle cost – Modular I/O keeps spares lean and helps standardize across bay types, which in many cases lowers total cost of ownership.
Serviceability – Front HMI, clear SOE, and COMTRADE exports shorten fault-finding and outage times.
You might notice that the REC670 scales well from a single feeder to a full yard. A utility client shared that after migrating to IEC 61850 GOOSE on REC670, they eliminated a surprising amount of copper interlocking wiring and cut commissioning hours dramatically.
Installation & MaintenanceCabinet & mounting – Install in a clean, dry switchgear cubicle; allow front access and rear wiring space; maintain ventilation around the unit.
Wiring – Use shielded twisted pair for IRIG-B/time sync and Ethernet as per ABB guidelines; keep VT and control wiring segregated; confirm interlocking logic with a formal test plan.
Grounding – Bond the IED chassis to the station earth; observe EMC practices to minimize induced noise.
Commissioning – Validate GOOSE datasets, time sync (SNTP or IRIG-B), and synchrocheck thresholds; save final PCM600 project backups.
Routine maintenance – Periodic logic and settings review, clean front filters/vents, check time sync status, and export SOE/disturbance logs. Firmware updates can be planned during outages to keep functions aligned with fleet standards.
CE marked; RoHS compliant
Designed and type-tested to relevant IEC standards for protective/measurement IEDs (e.g., IEC 60255 series, EMC/EMI)
IEC 61850 conformance for station bus; COMTRADE disturbance records
Manufacturer’s warranty: 12 months (as listed above)
ABB RTXP test switches (for safe secondary injection and isolation during maintenance)
IRIG-B time source or GPS clock for precise station-wide time alignment
Industrial Ethernet switches with PRP/HSR support for network redundancy
Send Inquiry to This Supplier
You May Also Like
-
ABB UNITROL 1020 – Digital AVR for Reliable Synchronous Generator ExcitationUS$ 3906.00MOQ: 1 Unit
-
ABB PPD113B01-20-111000 – Rack I/O Signal Interface Module for ABB Control SystemsUS$ 11950.00MOQ: 1 Pallet
-
ABB XVC770BE102 (3BHE021083R0102) – Excitation Control Board for UNITROL SystemsUS$ 4200.00MOQ: 1 Pallet
-
ABB PU519 (3BSE018681R1) – System Module for ABB Control/800xA Platforms, Built for Reliable Cabinet IntegrationUS$ 6100.00MOQ: 1 Unit
-
ABB UNS4681V511 – Control System Module for Reliable DCS/PLC Maintenance and UpgradesUS$ 3865.00MOQ: 1 Pallet
-
ABB PPD113B03-19-150000 – OEM Control Module for ABB Industrial Drive/Excitation SystemsUS$ 12388.00MOQ: 1 Unit
-
ABB REF615C_E HCFEAEAGABC2BAA11E – Feeder Protection Relay for MV Distribution Control and IEC 61850 AutomationUS$ 2960.00MOQ: 1 Unit
-
ABB UNS0881b-PV2 PCB – Original Replacement Board for ABB DCS/Advant CabinetsUS$ 3699.00MOQ: 1 Pallet
-
GATE DRIVER PCB (GRD) HIEE401782R0001, LT C391 AE01 LTC391AE01US$ 4600.00MOQ: 1 Pallet
-
ABB SPIET800 Ethernet CIU – Compact Ethernet Communication Interface for 800xA / Symphony Plus SystemsUS$ 13666.00MOQ: 1 Unit