YS-382B Disposable Diaper Permeability Tester
[Instrument Uses]
The Absorbency Performance Tester for Diapers is designed to measure the absorption speed, rewet performance, and penetration resistance of diapers and similar products.
[Product Specifications Translation]
1. The test solution for the test is controlled by a peristaltic pump for liquid addition, ensuring the stability and repeatability of the liquid addition. The liquid addition accuracy can reach ±1%.
2. The heating method for the test solution (normal saline) adopts water bath heating, which will not have any impact on the performance of the test solution.
3. Test fixture for children's disposable diapers: 3 U-shaped bases, 3 sample holders, 3 standard liquid addition modules, 3 standard pressure modules.
4. Test fixture for adult disposable diapers: 1 U-shaped base, 2 standard liquid addition modules, 2 standard pressure modules.
5. All sample fixtures are precisely processed from high-transparency materials, facilitating real-time observation of the measurement process, being corrosion-resistant and durable.
6. The entire machine adopts a desktop structure design, ensuring stable operation and convenient mobile installation.
7. The main control is implemented by Mitsubishi PLC, which is accurate and stable.
8. It is controlled and displayed by a KUNLUN Tongtai touch screen.
[Technical Parameters]
1. Test parameters for children's disposable diapers
1.1 Parameters of U-shaped sample base: B1: L:125±1mm W:122±1mm
B2: L:136±1mm W:135±1mm
B3: L:154±1mm W:152±1mm
1.2. Parameters of the standard liquid addition module: M1: L:100±1mm W:80±1mm
M2: L:108±1mm W:85±1mm
M3: L:125±1mm W:95±1mm
1.3. Standard test pressure module: Y1: L:100±1mm W:80±1mm
Y2: L:108±1mm W:85±1mm
Y3: L:125±1mm W:95±1mm
2. Test parameters for adult diapers
2.1 Parameters of U-shaped sample base: L:319±1mm W:200±1mm
2.2, Parameters of the standard liquid addition module: M1: L:170±1mm W:70±1mm
M2: L:170±1mm W:95±1mm
2.3, Standard Test Pressure Module: Y1: L:170±1mm W:70±1mm
Y2: L:170±1mm W:95±1mm
3. Pressure: 2.0 ± 0.2 KPa, 4.0 ± 0.2 KPa
4. Liquid flow rate: 480 ± 5 ml/min (for children), 750 ± 5 ml/min (for adults)
5. Time range: 0.00 ~ 9999.99 s
6. Heating range of test solution: Room temperature + 5℃ ~ 50℃
7. Power supply: AC 220V, 200W, 50Hz
8. Dimensions: L × W × H: 480mm × 460mm × 1000mm
[Configuration List]
1. Mainframe 1 unit
2. Water bath 1 unit
3. Infant diaper testing fixture set (U-shaped base B1, B2, B3, sample holder T1, T2, T3, standard testing liquid addition module M1, M2, M3, standard testing pressure application module Y1, Y2, Y3)
4. Adult diaper testing fixture set (U-shaped base B, standard testing liquid addition module M1, M2, standard testing pressure application module Y1, Y2)
5. Product certificate of conformity 1 sheet
6. Product user manual 1 copy
7. Delivery note 1 sheet
8. Acceptance form 1 sheet
9. Product brochure 1 copy
10. One-hundredth of a gram electronic balance 1 unit
Send Inquiry to This Supplier
You May Also Like
-
YS-121S Fluorescent Whitening Agent DetectorUS$ 20000.00 - 40000.00MOQ: 1 Unit
-
YG825E Non-woven Fabric Water Permeability TesterUS$ 3100.00 - 6200.00MOQ: 1 Unit
-
YG825 Type Non-Woven Fabric Hydrostatic Pressure Testing InstrumentUS$ 1500.00 - 3000.00MOQ: 1 Set
-
YG201E Type Textile Formaldehyde Content AnalyzerUS$ 3000.00 - 6000.00MOQ: 1 Set
-
YG401E-4 Type Martin Dale Wear Resistance InstrumentUS$ 2700.00 - 5400.00MOQ: 1 Unit
-
YG401G Type Martin Dale Wear Resistance InstrumentUS$ 5600.00 - 11200.00MOQ: 1 Unit
-
YS-38 Liquid Permeability TesterUS$ 1200.00 - 2400.00MOQ: 1 Unit
-
YS255 Liquid Backflow TesterUS$ 3000.00 - 6000.00MOQ: 1 Unit
-
YSZ-1 Friction Coefficient TesterUS$ 4000.00 - 8000.00MOQ: 1 Set
-
YG824 Type Non-woven Liquid Permeability TesterUS$ 1000.00 - 2000.00MOQ: 1 Unit