Home > Instruments & Meters > Test Instrument > Test Machine > UVA-340 Lamp UV Weathering Test Machine for Realistic Simulation

UVA-340 Lamp UV Weathering Test Machine for Realistic Simulation

UVA-340 Lamp UV Weathering Test Machine for Realistic Simulation photo-1
US$ 3500 - 6000 MOQ: 1 Set
Key Specifications
Get Latest Price
Brand Name:
Derui
Place of Origin:
China
Model Number:
DR-H302X-1
Payment & Shipping
Payment Methods:
Port of Shipment:
shenzhen
Delivery Detail:
15 days
Brand Name Derui
Place of Origin China
Model Number DR-H302X-1
Power Other, 220V
Usage Other, Rubber UV Weathering Test Equipment for Ozone Resistance

SPECIFICATION

Item

Specification

Outside dimension

1300W×500D×1460Hmm

Chamber material

Paint Spray

Temperature range

RT~70℃

Temperature fluctuation

±2℃

Temperature control

PID SSR control

Humidity range:

≥95%RH

Controller

Programmable controller, LCD touch screen

Control mode

Balance temperature humidity control (BTHC)

Test cycle setting

Exposure, condensation and water spray test cycle is programmable

Lamp power

40W/Piece

Distance from sample to lamp

50±2mm

Centre distance between the lamp

70mm

Irradiance

0.45~0.8W/m2 (optional)

UV lamps

Imported Atlas UV-A: 315-400nm (8pcs, 1600h lifetime)

Standard Specimen Size

75×290mm (24pcs) or 75x150mm (48pcs), max. thickness 5mm

Testing time

0~999H, adjustable

Protection system

Overload short circuit protection
Over temperature protection
Water lacking protection
Earth leakage protection
Auto shut off protection

In an era where product longevity is synonymous with brand credibility, the UVA-340 Lamp UV Weathering Test Machine stands as a gold standard for simulating solar ultraviolet (UV) degradation. Designed to replicate the critical 295–365 nm wavelength range of sunlight, this equipment enables manufacturers to predict material behavior under real-world conditions, from arid deserts to tropical climates.


Why UVA-340 Lamps Deliver Unmatched Realism

The UVA-340 lamp is the only fluorescent UV light source that closely matches the solar cutoff of 295 nm, making it indispensable for:

  • Accurate Spectral Alignment: Mimicking midday summer sunlight, critical for testing polymers, coatings, and textiles.

  • Predictive Aging: 1,000 hours of UVA-340 exposure can simulate 2–5 years of outdoor UV damage, depending on geographic irradiance levels.

A 2023 study by the International Association of Synthetic Testing (IAST) revealed that materials tested under UVA-340 lamps showed a 92% correlation with real-world degradation rates, compared to 78% for UVB-313 lamps.


Key Features for Precision Testing
  1. Dynamic Irradiance Control: Maintain 0.35–1.35 W/m² irradiance at 340 nm with ±2% stability, complying with ASTM G154 and ISO 4892-3.

  2. Multi-Stress Simulation: Combine UV exposure with temperature cycling (-20°C to 80°C) and humidity (10–95% RH) for tropical or desert conditions.

  3. Real-Time Data Analytics: Track gloss loss, color shift (ΔE), and tensile strength reduction via integrated software.

For example, a North American automotive supplier reduced warranty claims by 40% after identifying UV-induced cracking in headlight casings using UVA-340 testing.


Industry Applications Driving Innovation
  • Construction Materials: Validate UV stability of PVC window profiles and roofing membranes under prolonged sunlight.

  • Outdoor Gear: Test waterproof coatings on tents and backpacks for resistance to UV-driven hydrolysis.

  • Renewable Energy: Assess solar panel encapsulants for yellowing and delamination under 0.55 W/m² irradiance.

A breakthrough case involved a European packaging manufacturer using UVA-340 tests to develop a UV-resistant bioplastic that degrades only after 5 years of outdoor use, aligning with EU circular economy goals.


Compliance & Standards Integration

The UVA-340 Lamp UV Weathering Test Machine adheres to:

  • ASTM G154: Standard practice for operating fluorescent UV apparatus.

  • ISO 4892-3: Testing plastics under UV, humidity, and temperature cycles.

  • AATCC TM186: Weather resistance of textiles.


Optimizing Test Protocols
  1. Sample Preparation: Use non-reflective, flat specimens (e.g., 75mm x 150mm panels) to ensure uniform exposure.

  2. Cycle Configuration: Alternate between 8 hours of UV (0.55 W/m² at 50°C) and 4 hours of condensation (40°C) for ISO 4892-3 compliance.

  3. Calibration Checks: Validate irradiance monthly with a calibrated radiometer and replace lamps every 1,500 hours.



Product Tags: Uv Weather Aging Testing Chamber , UV Weather Tester , UVA-340 Lamp UV Weathering Test Machine for Realistic Simulation

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Business Type
Manufacturer
Year Established
2021
Factory Size
1,000-3,000 square meters
Annual Export Value
US$1 Million - US$1.5 Million

Recommended Categories

Explore top categories and find suppliers for your specific needs