Brand Name WOODWARD
Model Number UG-10D

Shenzhen Xunji independently developed the control net bus fiber optic module: IP30 protection level, corrugated aluminum reinforced casing, 35mm guide rail installation, DC 18-36V (9-18V optional) wide power supply, with relay alarm output, dual power redundancy, and isolation protection functions. Ci-CF110 to fiber optic supports one fiber optic interface and one bus data interface, while Ci-CF120 to fiber optic supports two cascaded up and down fiber optic interfaces and one bus data interface.

Bus data interface

*BNC-F interface form

*Supports ControlNet fieldbus protocol, communication rate: 5Mbps

*Isolation voltage: Instantaneous isolation voltage 5000V, continuous isolation voltage 1000V

*Terminal resistance: There is no terminal resistance inside this device. Please decide whether to connect it externally as needed

Fiber optic interface

*Fiber wavelength: multimode 850nm, 1310nm; Single mode 1310nm, 1550nm

*Transmission fiber: multimode 50/125um, 62.5/125um, 100/140um, single mode 8.3/125um, 9/125um, 10/125um

*Transmission distance: multimode 2km, single mode 20km, longer distance optional

*Fiber optic interface type: ST, SC, FC optional, standard ST optical interface

Power supply and protection

*Power supply: Dual power redundant input, DC 18-36V (9-18V optional) typical DC24V, power consumption less than 1.5W, with DC1000V voltage isolation and reverse protection function, industrial terminal interface

*Relay alarm output: Fiber optic link fault alarm output, contact capacity: DC48V/1 A, industrial terminal interface



Contact information: 15359293870

WhatsApp:+86 15359293870

Contact person: KELLY

Email: geabbdcs@gmail.com   386353502@qq.com

Official website:




The scale is one tenth of a degree.

This module has 16 24 VDC digital outputs, PNP type, with a maximum current of 0.5 A per channel, typically used for heating and/or cooling.

Any available output can also be used to control the machine cycle.

All outputs have current cycling circuits for sensing loads, and have short circuit, overload, and overheat protection.

There is also a 24 VDC NPN digital input to measure the period of the applied signal.

The maximum input frequency is 1 kHz.

This module is installed on R-BUS (x) and receives power from it.

Product features:

● 8 optical isolation inputs for thermocouples

J, K type thermocouples

16 optical isolated digital outputs

1 optical isolation frequency input 1,5kHz

● Software configuration for TC or TR input

● Diagnostic LEDs for power, output, and alarms

● Provide detachable connectors

● Compliant with UL508

e rail fastening, in accordance with EN 50022-35 standard

Gross weight (g): 206,8

TBUS DIN rail for expansion modules and bus couplers

Rated control circuit power voltage US: 18 V DC 30 V DC (including all tolerances, including residual voltage)

Rated control circuit power voltage US: 24 V DC (A1/A2)

Rated control power supply current IS: typical value 110 mA

Limit continuous current: maximum 6 A (for loop current paths A1/A1 and A2/A2)

Delay time: typical value of 20 ms (depending on load, in case of voltage drop of US)

Protection circuit: Yes, within the operating voltage limit range

Status display: 3x green LED, 1x red LED

Input Description: Number, HTL type

Input quantity: 10 (dual channel, up to SIL 3)

20 (single channel, up to SIL 2)

Input voltage range, "0" signal: 0 V DC 5 V DC (for safe shutdown)

Input voltage range, "1" signal: 11 V DC 30 V DC

Cable length: maximum 2000 m

Status display: 20 x green LED (1 LED per input)

Power consumption: typical value 4 mA

Number of outputs: 4 (safe semiconductor output, up to Cat. 4 (according to EN ISO 13849-1)

2 (negative switching output)

Precautions for protecting the circuit: Yes, within the operating voltage limit range

Short circuit protection: Yes

Output voltage:

Leakage current: maximum 2 mA

Maximum capacitive load: maximum 1 µ F (electronic components)

Limit continuous current: 2 A (per channel, see derating)


Product Tags: UG-10D , WOODWARD , Governor module

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market

Recommended Categories

Explore top categories and find suppliers for your specific needs