0.5 Accuracy Low Voltage dc Voltmeter Panel Mount Electric Voltage Monitor RS485 Port With Modbus-RTU
Function |
Description&Value |
Measurement |
Three-phase AC kWh, kVarh, Active Power, Reactive Power, Forward&Reverse Power, Current, Voltage, Zero Sequence Voltage, Zero sequence Current, Voltage-phase Angle, Voltage&Current Unbalance, Power Factor,Harmonic, Frequency |
Display |
LCD display |
Communication (Optional) |
RS485,Modbus-RTU protocol;(1 start bit,8 data bit,1 stop bit,no parity) Baud Rate 1200~38400 bps etc. |
Alarm Output (Optional) |
1 channel passive relay,contact capacity 3A/30VDC,3A/250VAC, Used for high,low,unbalance alarm etc. |
Analog Output (Optional) |
1~5V DC or 4~20mA DC |
DI/DO Switching (Optional) |
DI (Digital input): 2-channel or 4-channel dry contact digital input with built in power supply DO (Digital output): 2-channel digital output with NO relay contact. Capacity: 3A/30V DC,3A/250V AC |
Parameter |
Description&Value |
||
Input |
Rated Voltage |
AC Voltage Input: 400V AC L-L (via direct connetion); 100V AC L-L (via -/100V AC PTs) |
|
Rated Current |
AC Current Input: 5A AC or 1A AC (via -/5A AC or -/1A AC CTs) |
||
Overload |
Current&Voltage input overload:1.2 times rated value(continuous); 10 times rated value /1 second |
||
Frequency |
45~65Hz |
||
Power Consumption |
Power consumption of each current&voltage input circuit is less than 0.5VA |
||
Measuring Accuracy |
Voltage |
0.2% |
|
Current |
0.2% |
||
Active Power |
0.5% |
||
Reactive Power |
1.0% |
||
kWh |
0.5% |
||
kVarh |
1.0% |
||
Frequency |
±0.05Hz |
||
Harmonic |
±1% |
||
Power Supply |
Voltage Range |
85-265V AC/DC; 24V or 48V DC (±20%) |
|
Power Consumption |
≤10VA |
||
Insulation resistance |
≥ 100MΩ |
||
Power frequency withstand voltage |
Between Power supply//Switching Output// Current Input//voltage Input and Transmitting// Communication //Pulse Output//switching input AC 2 kV 1min; Between Power supply、switching output、Current Input、voltage Input AC 2 kV 1min; Between Transmitting、Communication、Pulse Output、switching input AC 1kV 1 min; |
||
Condition |
Description&Value |
Temperature |
Operation: -25℃~+65℃; Storage: -40°C ~+80°C |
Humidity |
≤95%RH,no condensation,without corrosive gas |
Altitude |
≤ 2500m |
Send Inquiry to This Supplier
You May Also Like
-
Acrel 20(100)A Three Phase Smart Energy Meter Equipped With 3 Split Core CTs Wattmeter Power Meter ADW300W/C 100A InputNegotiableMOQ: 1
-
Panel Mountable Type DC Ammeter AMC72-DI/C Input DC0-5A LED Display Digital DC AmmeterNegotiableMOQ: 1
-
Acrel LCD Display Relay Alarm Output Direct Connect China Solar pv Energy Meters Electronic Measuring InstrumentsNegotiableMOQ: 1
-
LCD Display PZ72L-DE Multi Tariff Energies Optional dc Solar pv Energy Monitor Energy Meter for Solar System Metering SystemNegotiableMOQ: 1
-
Multi Tariff Energies Optional Acrel PZ72L-DE LCD Display Energy Smart Meter for Solar Energy Metering SystemNegotiableMOQ: 1
-
China Manufacturer High Precision PZ72L-DE LCD Display pv Energy Monitor Energy Consumption Electric MeterNegotiableMOQ: 1
-
Acrel China Manufacturer Direct Connect DC Panels dc Solar Energy Meter WithRS485 InterfaceNegotiableMOQ: 1
-
China Manufacturer Multi Tariff Energies Optional CE Certificates Acrel Solar dc Energy Meter Single Phase PriceNegotiableMOQ: 1
-
China Manufacturer Multi Tariff Energies Optional CE Certificates Acrel Solar dc Energy Meter Single Phase PriceNegotiableMOQ: 1
-
Acrel PZ72L-DE Multi Tariff Energies Optional DC Voltage Photovoltaic Electric Power Watt Meter for HouseNegotiableMOQ: 1