Module Spare PartsIC690RFH008

Module Spare PartsIC690RFH008 photo-1
US$ 1 - 100000 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
ABB
Model Number:
IC690RFH008
Payment & Shipping
Payment Methods:
Port of Shipment:
xiamen
Delivery Detail:
1 days
Brand Name ABB
Model Number IC690RFH008


Focus on DCS, PLC, robot control system and large servo system.

Main products: various modules / cards, controllers, touch screens, servo drivers.

Advantages: supply of imported original products, professional production parts,

Fast delivery, accurate delivery time,

The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands




IC690RFH008

Figure 8 RS232 signals. DTR and DSR as well as RTS and CTS signals are internally connected. The RS232 cable should not have TxD and RxD signals connected across. ABB AC PC 140 max. length 3 m serial port 5 4 3 2 1 9 8 7 6 X4 X4 Description 1 NC 2 TxD 3 RxD 4 DTR 5 SGND 6 DSR 7 RTS 8 CTS 9 NC 10 Earthing and Termination RS485 Bus The RS485 network should not be directly earthed at any point. All the devices on the network should be well earthed using their corresponding earthing terminals. As always, the earthing wires should not form any closed loops, and all the devices should be earthed to a common earth. The RS485 network must be terminated using 120 Ω resistors at both ends of the network as shown in Figure 9. These resistors are already resident on the adapter. Use jumpers S2 and S3 to connect the termination resistors. Figure 9 Termination for the RS485 link. The connections may only be made with the drive disconnected from the power source. Terminated Terminated 11 PROGRAMMING Chapter 3 – Programming This chapter describes how to program the ACS 140 drive for Modbus communication.The reader should be already familiar with programming the drive parameters using the ACS 100 - PAN control panel, and the way the parameters are arranged in groups. For details, see the ACS 140 Programming Guide. General When the ACS 100 - PAN control panel is attached to the drive, the panel communicates using the Modbus protocol and the settings given in Table 2. When power is connected, the ACS 140 will automatically check for the presence of the panel. If the panel is detected, the ACS 140 will set up the Modbus communication using the default settings shown in Table 2. Thissettings of the ACS 140 can be

Product Tags: spot goods , Large warehouse management

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Verified Business License
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe, Central America, Northern Europe, Southern Europe, South Asia, Domestic Market

Recommended Categories

Explore top categories and find suppliers for your specific needs