Module Spare Parts 5302-MBP-MCM4
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
| 5302-MBP-MCM4 |
Protection functions: ANSI
code Description
Generator differential
Power transformer differential
87G
87T
three-phase
three-phase for 2- and 3-winding transformers
Definite time overcurrent (undercurrent)
Overcurrent or undercurrent with peak value
evaluation
Restricted earth fault
Voltage-controlled overcurrent
Inverse time overcurrent
Directional definite time overcurrent
Directional inverse time overcurrent
Negative phase sequence current
Definite time overvoltage (undervoltage)
100% stator and rotor earth fault
protection
Dead machine protection
51
50
87N
51/27
51
67
67
46
59
27
64
64 S
64 R
50AE
definite time delay, for phase and earth-fault, overand undercurrent
instantaneous operation or with definite time delay,
value evaluation wide frequency range, over- and undercurrent
overcurrent operation with definite time delay*
operation restrained by undervoltage
inverse current dependent time delay, for phase and
earth fault (51N)
definite time tripping
inverse time tripping
negative phase sequence current with definite time delay or
inverse time delay with thermal replica
definite time delay, over- and undervoltage
Applicable also for
- stator E/F (95%) (59 G/N)
- rotor E/F (64 R) **
- intertum fault protection
based on the displacement principle calculation of the
earth fault resistance.
in addition the units REX010 and REX011 are required
Underimpedance
Minimum reactance
Pole slip protection
High-voltage distance protection
Distance protection
21
40
78
21Z 21Z circular characteristics centered at origin of impedance plane circular characteristics for loss of excitation protection detecting loss of synchronism of a generator as against the network 6-system high-voltage protection distance protection with overcurrent or underimpedance starting Power 32 37 any characteristic angle, over and underpower for: - active power - reactive power - reverse power protection - minimum forward power Overload Negative phase sequence current Overtemperature 49 46 49 thermal replica with operating characteristic according to ASA-C50.13*** for: - standard stator current (49 S) - rotor current (49 R) evaluation of negative phase sequence of currents inverse time delay; with terminal replica thermal protection with precise thermal replica and 216GA62.
Send Inquiry to This Supplier
You May Also Like
-
Module Spare Parts 9300 9832 9802US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts CC-PCNT02US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 05701-A-0301US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 05701-A-0302US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 05701-A-0325US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 05701-A-0326US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 05701-A-0329US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 05701-A-0502US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 05704-A-0121US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 05704-A-0144US$ 1 - 100000MOQ: 1 Piece