Module Spare Parts 05701-A-0301
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
| 05701-A-0301 |
Breath Timing Definition Tlow Low Time The time in seconds that the ventilator holds the low pressure level in APRV mode. . Patient Synchrony Definition Insp Trigger Inspiratory Trigger The patient effort required to initiate the inspiratory phase of a breath. The trigger can be set as either a positive flow value (Flow Trigger) or a negative pressure deflection below PEEP (Pressure Trigger). Exp Trigger Expiratory Trigger The percentage of peak flow at which the pressure supported breath inspiratory phase ends and the expiratory phase begins. Rise Time Rise Time The time in milliseconds for pressure to reach 90% of the set inspiratory pressure. PS Rise Time Pressure Support Rise Time The time in milliseconds for pressure to reach 90% of the set pressure support level. Bias Flow Bias Flow The continuous flow that is circulated through the patient circuit during the expiratory phase of the breath cycle. The bias flow may be increased above this setting by the ventilator for some FiO2 settings. Tsupp Pressure Support Time The maximum inspiratory time for a pressure-supported breath. . Safety Definition Pmax Maximum Pressure The maximum pressure allowed in the patient breathing circuit. Once reached, the inspiratory phase ends, and the ventilator immediately begins the expiratory phase. Plimit Pressure Limit The pressure at which the breath is limited and held for the remaining inspiratory time in a volume-controlled breath. Pmin Minimum Pressure The minimum target pressure offset from PEEP allowed in PRVC, VS, SIMV PRVC, and BiLevel VG modes. Minimum Rate Minimum respiratory rate The minimum number of breaths per minute a patient must draw before the ventilator delivers a backup breath. Backup Pinsp Backup Inspiratory Pressure The pressure above PEEP that the ventilator maintains as it delivers a mechanical breath in CPAP/PS and NIV modes. Backup Tinsp Backup Inspiratory Time The time in seconds that the ventilator uses to deliver the inspiratory phase for a mechanical breath in VS, CPAP/PS and NIV modes.
Send Inquiry to This Supplier
You May Also Like
-
Module Spare Parts 05704-A-0121US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 05704-A-0144US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 51303940-150US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 5302-MBP-MCM4US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 8C-PCNT01US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 8C-PCNT01 51454363-175US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 8C-PCNT02 51454363-275US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 90088-A-9001US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 9200-06-02-10-00US$ 1 - 100000MOQ: 1 Piece
-
Module Spare Parts 9300 9832 9802US$ 1 - 100000MOQ: 1 Piece